Ion-Exchange Based Immobilization of Chromogenic Reagents on Microfluidic Paper Analytical Devices

被引:23
|
作者
Rahbar, Mohammad [1 ,2 ,3 ]
Wheeler, Aaron R. [2 ,3 ,4 ]
Paull, Brett [1 ]
Macka, Mirek [1 ,5 ,6 ]
机构
[1] Univ Tasmania, Sch Nat Sci, Australian Ctr Res Separat Sci ACROSS, Hobart, Tas 7001, Australia
[2] Univ Toronto, Dept Chem, 80 St George St, Toronto, ON M5S 3H6, Canada
[3] Donnelly Ctr Cellular & Biomol Res, 160 Coll St, Toronto, ON M5S 3E1, Canada
[4] Univ Toronto, Inst Biomat & Biomed Engn, 164 Coll St, Toronto, ON M5S 3G9, Canada
[5] Mendel Univ Brno, Dept Chem & Biochem, Zemedelska 1, CZ-61300 Brno, Czech Republic
[6] Brno Univ Technol, Cent European Inst Technol, Purkynova 123, CZ-61200 Brno, Czech Republic
基金
澳大利亚研究理事会; 加拿大自然科学与工程研究理事会;
关键词
MU-PADS; NANOPARTICLES; SURFACE; ASSAY;
D O I
10.1021/acs.analchem.9b01288
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Distance-based detection methods, as used in development of microfluidic paper analytical devices (mu PADs), rely on the dynamic formation of a colored band along the length of the paper microfluidic channels. The color change is driven by the reaction of chromogenic reagents (typically water-insoluble) that are bound to the paper, thus not subject to being washed away by the sample flow along the detection channel. Here, we introduce the use of an anion-exchange filter paper (as a replacement for standard, unmodified filter paper) for distance-based detection in mu PADs, in order to immobilize the water-soluble anionic reagents upon the paper detection channels based on ion-exchange interactions of the oppositely charged paper (protonated tertiary amine groups) and the anionic groups of the reagents. The ion-exchange (IE) paper was initially characterized and its properties were compared with standard cellulose paper. The IE paper was shown to be capable of strong retention of anionic reagents exhibiting acidic functional groups (carboxylic, sulfonic), which become deprotonated and negatively charged when in contact with the IE paper. The effect of the ionic strength (10-250 mM Cl-) and pH (1-13) on the immobilization of the investigated reagents were also determined. The IE-mu PADs were then modified with anionic chromogenic reagents and applied to distance-based determination of total calcium (LOD = 0.03 mM) and total acidity (LOD = 2.5 mM) content in serum and wine samples, respectively. The detailed mechanisms of the developed assays on the IE paper are also discussed. We propose that IE-mu PADs represent a useful new addition to the distance-based detection toolbox and considerably enhance the applicability of such a detection method.
引用
收藏
页码:8756 / 8761
页数:6
相关论文
共 50 条
  • [21] Simultaneous analysis of multiple adulterants in milk using microfluidic paper-based analytical devices
    Guinati, Barbara G. S.
    Sousa, Lucas R.
    Oliveira, Karoliny A.
    Coltro, Wendell K. T.
    ANALYTICAL METHODS, 2021, 13 (44) : 5383 - 5390
  • [22] Application of Paper-Based Microfluidic Analytical Devices (μPAD) in Forensic and Clinical Toxicology: A Review
    Musile, Giacomo
    Grazioli, Cristian
    Fornasaro, Stefano
    Dossi, Nicolo
    De Palo, Elio Franco
    Tagliaro, Franco
    Bortolotti, Federica
    BIOSENSORS-BASEL, 2023, 13 (07):
  • [23] Atomically Dispersed Manganese on Graphene Nanosheets as Biocompatible Nanozyme for Glutathione Detection in Liver Tissue Lysate Using Microfluidic Paper-based Analytical Devices
    Baruah, Diksha J.
    Thakur, Ashutosh
    Roy, Esha
    Roy, Kallol
    Basak, Sumanjita
    Neog, Dipankar
    Bora, Himangsu K.
    Konwar, Rituraj
    Chaturvedi, Vikash
    Shelke, Manjusha V.
    Das, Manash R.
    ACS APPLIED MATERIALS & INTERFACES, 2023, 15 (41) : 47902 - 47920
  • [24] Driving flows in microfluidic paper-based analytical devices with a cholinium based poly(ionic liquid) hydrogel
    Akyazi, Tugce
    Tudor, Alexandru
    Diamond, Dermot
    Basabe-Desmonts, Lourdes
    Florea, Larisa
    Benito-Lopez, Fernando
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 261 : 372 - 378
  • [25] Instrument-free fabrication of microfluidic paper-based analytical devices through 3D pen drawing
    Sousa, Lucas R.
    Duarte, Lucas C.
    Coltro, Wendell K. T.
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 312
  • [26] Microfluidic paper-based analytical devices (μPADs) for fast and ultrasensitive sensing of biomarkers and monitoring of diseases
    Abdollahi-Aghdam, Abdollah
    Majidi, Mir Reza
    Omidi, Yadollah
    BIOIMPACTS, 2018, 8 (04) : 237 - 240
  • [27] Uncovering the Formation of Color Gradients for Glucose Colorimetric Assays on Microfluidic Paper-Based Analytical Devices by Mass Spectrometry Imaging
    de Freitas, Soraia, V
    de Souza, Fabricio R.
    Rodrigues Neto, Jorge C.
    Vasconcelos, Gessica A.
    Abdelnur, Patricia, V
    Vaz, Boniek G.
    Henry, Charles S.
    Coltro, Wendell K. T.
    ANALYTICAL CHEMISTRY, 2018, 90 (20) : 11949 - 11954
  • [28] Metabolic biomarker modeling for predicting clinical diagnoses through microfluidic paper-based analytical devices
    Perez-Rodriguez, Michael
    Del Pilar Canizares-Macias, Maria
    MICROCHEMICAL JOURNAL, 2021, 165
  • [29] Advances on microfluidic paper-based electroanalytical devices
    Holman, Joseph Benjamin
    Shi, Zhengdi
    Fadahunsi, Adeola A.
    Li, Chengpan
    Ding, Weiping
    BIOTECHNOLOGY ADVANCES, 2023, 63
  • [30] Geometrical Alignment of Multiple Fabrication Steps for Rapid Prototyping of Microfluidic Paper-Based Analytical Devices
    Rahbar, Mohammad
    Nesterenko, Pavel N.
    Paull, Brett
    Macka, Mirek
    ANALYTICAL CHEMISTRY, 2017, 89 (22) : 11918 - 11923