Measurement of rivaroxaban and apixaban in serum samples of patients

被引:22
作者
Harenberg, Job [1 ]
Kraemer, Sandra [1 ]
Du, Shanshan [1 ]
Zolfaghari, Shabnam [1 ]
Schulze, Astrid [2 ]
Kraemer, Roland [3 ]
Weiss, Christel [4 ]
Wehling, Martin [1 ]
Lip, Gregory Y. H. [5 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Dept Clin Pharmacol, D-68169 Mannheim, Germany
[2] Heidelberg Univ, Dept Orthoped & Trauma Surg, Med Fac Mannheim, D-68167 Mannheim, Germany
[3] Heidelberg Univ, Inst Inorgan Chem, D-69116 Heidelberg, Germany
[4] Heidelberg Univ, Med Fac Mannheim, Dept Biometry & Stat, D-68169 Mannheim, Germany
[5] Univ Birmingham, Ctr Cardiovasc Sci, City Hosp Birmingham, Birmingham B18 7QH, W Midlands, England
关键词
Apixaban; chromogenic substrate methods; direct oral anticoagulants; plasma; rivaroxaban; serum; FACTOR-XA INHIBITOR; DIRECT ORAL ANTICOAGULANTS; TANDEM MASS-SPECTROMETRY; MAJOR ORTHOPEDIC-SURGERY; HEALTHY-SUBJECTS; VENOUS THROMBOEMBOLISM; DABIGATRAN ETEXILATE; NETWORK METAANALYSIS; ATRIAL-FIBRILLATION; LABORATORY ASSAYS;
D O I
10.1111/eci.12291
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The determination of rivaroxaban and apixaban from serum samples of patients may be beneficial in specific clinical situations when additional blood sampling for plasma and thus the determination of factor Xa activity is not feasible or results are not plausible. Materials and methods The primary aim of this study was to compare the concentrations of rivaroxaban and apixaban in serum with those measured in plasma. Secondary aims were the performance of three different chromogenic methods and concentrations in patients on treatment with rivaroxaban 10 mg od (n = 124) or 20 mg od (n = 94) or apixaban 5 mg bid (n = 52) measured at different time. Results Concentrations of rivaroxaban and apixaban in serum were about 20-25% higher compared with plasma samples with a high correlation (r = 0.79775-0.94662) using all assays (all P < 0.0001). The intraclass correlation coefficients were about 0.90 for rivaroxaban and 0.55 for apixaban. Mean rivaroxaban concentrations were higher at 2 and 3 h compared with 1 and 12 h after administration measured from plasma and serum samples (all P-values < 0.05) and were not different between 1 vs. 12 h (plasma and serum). Conclusions The results indicate that rivaroxaban and apixaban concentrations can be determined specifically from serum samples.
引用
收藏
页码:743 / 752
页数:10
相关论文
共 41 条
[41]   Characterization of Efflux Transporters Involved in Distribution and Disposition of Apixaban [J].
Zhang, Donglu ;
He, Kan ;
Herbst, John J. ;
Kolb, Janet ;
Shou, Wilson ;
Wang, Lifei ;
Balimane, Praveen V. ;
Han, Yong-Hae ;
Gan, Jinping ;
Frost, Charles E. ;
Humphreys, W. Griffith .
DRUG METABOLISM AND DISPOSITION, 2013, 41 (04) :827-835