How reliable are texture measurements?

被引:3
|
作者
Robins, Marthony [1 ,2 ,3 ,4 ]
Solomon, Justin [1 ,3 ,4 ]
Hoye, Jocelyn [1 ,2 ,3 ,4 ]
Abadi, Ehsan [1 ,3 ,4 ]
Marin, Daniele [1 ,3 ,4 ]
Samei, Ehsan [1 ,2 ,3 ,4 ]
机构
[1] Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[2] Med Phys Grad Program, Durham, NC 27705 USA
[3] Dept Radiol, Durham, NC 27705 USA
[4] Duke Univ, Med Ctr, Durham, NC 27705 USA
关键词
CT; simulation; texture features; radiomics; voxel size; slice thickness; reconstruction algorithm; VOLUME ESTIMATION; LUNG NODULES; CT; FEATURES; SIZE;
D O I
10.1117/12.2294591
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to assess the bias (objectivity) and variability (robustness) of computed tomography (CT) texture features (internal heterogeneities) across a series of image acquisition settings and reconstruction algorithms. We simulated a series of CT images using a computational phantom with anatomically-informed texture. 288 clinically-relevant simulation conditions were generated representing three slice thicknesses (0.625, 1.25, 2.5 mm), four in-plane pixel sizes (0.4, 0.5, 0.7, 0.9 mm), three dose levels (CTDIvol = 1.90, 3.75, 7.50 mGy), and 8 reconstruction kernels. Each texture feature was sampled with 4 unique volumes of interest (VOIs) (244, 1953, 15625, 125000 mm(3)). Twenty-one statistical texture features were calculated and compared between the ground truth phantom (i.e., pre-imaging) and its corresponding post-imaging simulations. Metrics of comparison included (1) the percent relative difference (PRD) between the post-imaging simulation and the ground truth, and (2) the coefficient of variation (%COV) across simulated instances of texture features. The PRD and %COV ranged from -100% to 4500%, and 0.8% to 49%, respectively. PRD decreased with increased slice thickness, in-plane pixel size, and dose. The dynamic range of results indicate that image acquisition and reconstruction conditions (i.e., slice thicknesses, in-plane pixel sizes, dose levels, and reconstruction kernels) can lead to significant bias and variability in texture feature measurements.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] HOW RELIABLE ARE BEARINGS
    SNARE, B
    BALL BEARING JOURNAL, 1970, (162): : 3 - &
  • [42] HOW RELIABLE ARE THE NUMBERS
    HELLER, SR
    BIGWOOD, DW
    AGRICULTURAL RESEARCH, 1989, 37 (01) : 2 - &
  • [43] How reliable are VPNs?
    Telephony, 3 (28):
  • [44] HOW RELIABLE ARE AMBULATORY PATIENT-MONITORED BLOOD-SUGAR MEASUREMENTS - A MULTICENTER TRIAL
    SCHOFFLING, K
    BACHMANN, W
    DROST, H
    GRIES, FA
    HAUPT, E
    KNICK, B
    LOOK, D
    PETRIDES, P
    WILLMS, B
    KOBERSTEIN, R
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1982, 107 (16) : 605 - 609
  • [45] How reliable are phonetic data collected remotely? Comparison of recording devices and environments on acoustic measurements
    Ge, Chunyu
    Xiong, Yixuan
    Mok, Peggy
    INTERSPEECH 2021, 2021, : 3984 - 3988
  • [46] How reliable are serial echocardiographic measurements in detecting regression in left ventricular hypertrophy and changes in function?
    Gardin, JM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (05) : 1633 - 1636
  • [47] How many streamlines are required for reliable probabilistic tractography? Solutions for microstructural measurements and neurosurgical planning
    Reid, Lee B.
    Cespedes, Marcela, I
    Pannek, Kerstin
    NEUROIMAGE, 2020, 211
  • [48] Craniofacial Landmarks in Young Children: How Reliable Are Measurements Based on 3-Dimensional Imaging?
    Metzler, Philipp
    Bruegger, Lea S.
    Gujer, Astrid L. Kruse
    Matthews, Felix
    Zemann, Wolfgang
    Graetz, Klaus W.
    Luebbers, Heinz-Theo
    JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 (06) : 1790 - 1795
  • [49] How Reliable Are Ultra-Short-Term HRV Measurements during Cognitively Demanding Tasks?
    Bernardes, Andre
    Couceiro, Ricardo
    Medeiros, Julio
    Henriques, Jorge
    Teixeira, Cesar
    Simoes, Marco
    Duraes, Joao
    Barbosa, Raul
    Madeira, Henrique
    Carvalho, Paulo
    SENSORS, 2022, 22 (17)
  • [50] ARE TACTILE IOP MEASUREMENTS RELIABLE
    COHEN, A
    FLEISCHMAN, JA
    SCHULTZ, JS
    FRANKEL, MR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S348 - S348