Respiratory-Gated Positron Emission Tomography and Breath-Hold Computed Tomography Coupling to Reduce the Influence of Respiratory Motion: Methodology and Feasibility

被引:28
作者
Daouk, J. [1 ]
Fin, L. [1 ]
Bailly, P. [1 ]
Meyer, M. -E. [1 ]
机构
[1] Univ Hosp, Dept Nucl Med, Amiens, France
关键词
Breath-hold CT; diagnosis; oncology; PET-CT; respiratory gating; ATTENUATION CORRECTION; LUNG-CANCER; CHEST CT; PET DATA; ARTIFACTS; LESIONS;
D O I
10.1080/02841850802627437
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Respiratory motion causes uptake in positron emission tomography (PET) images of chest and abdominal structures to be blurred and reduced in intensity. Purpose: To compare two respiratory-gated PET binning methods (based on frequency and amplitude analyses of the respiratory signal) and to propose a BH-based method based on an additional breath-hold computed tomography (CT) acquisition. Material and Methods: Respiratory-gated PET consists in list-mode (LM) acquisition with simultaneous respiratory signal recording. A phantom study featured rectilinear movement of a 0.5-ml sphere filled with 18F-fluorodeoxyglucose (18F-FDG) solution, placed in a radioactive background (sphere-to-background contrast 6:1). Two patients were also examined. Three figures of merit were calculated: the target-to-background ratio profile (TBRP) in the axial direction through the uptake (i.e., the sphere or lesion), full-width-at-half-maximum (FWHM) values, and maximized standard uptake values (SUVmax). Results: In the phantom study, the peak TBRP was 0.9 for non-gated volume, 1.83 for BH-based volume, and varied between 1.13 and 1.73 for Freq-based volumes and between 1.34 and 1.66 for Amp-based volumes. A reference volume (REF-static) was also acquired for the phantom (in a static, expiratory state), with a peak TBRP at 1.88. TBRPs were computed for patient data, with higher peak values for all gated volumes than for non-gated volumes. Conclusion: Respiratory-gated PET acquisition reduces the blurring effect and increases image contrast. However, Freq-based and Amp-based volumes are still influenced by inappropriate attenuation correction and misregistration of mobile lesions on CT images. The proposed BH-based method both reduces motion artifacts and improves PET-CT registration.
引用
收藏
页码:144 / 155
页数:12
相关论文
共 21 条
  • [1] Design of respiration averaged CT for attenuation correction of the PET data from PET/CT
    Chi, Pai-Chun Melinda
    Mawlawi, Osama
    Nehmeh, Sadek A.
    Erdi, Yusuf E.
    Balter, Peter A.
    Luo, Dershan
    Mohan, Radhe
    Pan, Tinsu
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2039 - 2047
  • [2] Fast reconstruction of 3D PET data with accurate statistical modeling
    Comtat, C
    Kinahan, PE
    Defrise, M
    Michel, C
    Townsend, DW
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1083 - 1089
  • [3] Daouk J, 2008, 5 IEEE INT S BIOM IM, P1323
  • [4] Respiratory gating in positron emission tomography:: A quantitative comparison of different gating schemes
    Dawood, Mohammad
    Buether, Florian
    Lang, Norbert
    Schober, Otmar
    Schaefers, Klaus P.
    [J]. MEDICAL PHYSICS, 2007, 34 (07) : 3067 - 3076
  • [5] Impact of 18FDG-PET/CT on biological target volume (BTV) definition for treatment planning for non-small cell lung cancer patients
    Devic, Slobodan
    Tomic, Nada
    Faria, Sergio
    Dean, Geoffrey
    Lisbona, Robert
    Parker, William
    Kaufman, Chris
    Podgorsak, Ervin B.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) : 89 - 92
  • [6] Respiration-induced attenuation artifact at PET/CT: Technical considerations
    Goerres, GW
    Burger, C
    Kamel, E
    Seifert, B
    Kaim, AH
    Buck, A
    Buehler, TC
    von Schulthess, GK
    [J]. RADIOLOGY, 2003, 226 (03) : 906 - 910
  • [7] PET-CT image co-registration in the thorax: influence of respiration
    Goerres, GW
    Kamel, E
    Heidelberg, TNH
    Schwitter, MR
    Burger, C
    von Schulthess, GK
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (03) : 351 - 360
  • [8] Hashimoto Y, 2006, J NUCL MED, V47, P426
  • [9] 18F-FDG PET for mediastinal staging of lung cancer:: Which SUV threshold makes sense?
    Hellwig, Dirk
    Graeter, Thomas P.
    Ukena, Dieter
    Groeschel, Andreas
    Sybrecht, Gerhard W.
    Schaefers, Hans-Joachim
    Kirsch, Carl-Martin
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (11) : 1761 - 1766
  • [10] Attenuation correction for a combined 3D PET/CT scanner
    Kinahan, PE
    Townsend, DW
    Beyer, T
    Sashin, D
    [J]. MEDICAL PHYSICS, 1998, 25 (10) : 2046 - 2053