Analysis of knee functional flexion axis in navigated TKA: identification and repeatability before and after implant positioning

被引:10
作者
Colle, Francesca [1 ,2 ,3 ]
Lopomo, Nicola [1 ,2 ]
Bruni, Danilo [1 ]
Visani, Andrea [1 ]
Iacono, Francesco [1 ]
Zaffagnini, Stefano [1 ]
Marcacci, Maurilio [1 ]
机构
[1] Ist Ortoped Rizzoli, Lab Biomeccan & Innovaz Tecnol, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli, Lab NanoBioteconol NaBi, I-40136 Bologna, Italy
[3] Scuola Super Sant Anna, Biorobot Inst, I-56127 Pisa, Italy
关键词
Knee functional flexion axis; Repeatability; TKA; CAS; FEMORAL ROTATIONAL ALIGNMENT; SURGICAL EPICONDYLAR AXIS; JOINT COORDINATE SYSTEM; TRANSEPICONDYLAR AXIS; IN-VIVO; STANDARDIZATION PROPOSAL; ANTEROPOSTERIOR AXIS; HELICAL AXIS; DISTAL FEMUR; ARTHROPLASTY;
D O I
10.1007/s00167-013-2780-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Providing correct rotational alignment of femoral component in total knee arthroplasty (TKA) is mandatory to achieve correct kinematics, good ligament balance and patellar tracking. The purpose of this study was to evaluate potential clinical applications of functional flexion axis (FFA) by analysing the differences between pre- and post-implant placement. This evaluation was supported by the analysis of repeatability, assessing the robustness of the proposed method. Methods Anatomical acquisitions and passive kinematics were acquired on 87 patients undergoing TKA using a commercial navigation system. Knee FFA was estimated, before and after implant positioning, from three flexion-extension movements between 0 and 120 degrees. The angle between FFA and transepicondylar axis was analysed in frontal and axial planes. Repeatability coefficient and intraclass correlation coefficient (ICC) were used to analyse the reliability and the agreement in identifying the axis. Results The analysed angle presented differences between pre- and post-operative conditions only in the frontal plane (from -8.3 +/- 5.5 degrees to -2.8 +/- 5.3 degrees) (p<0.0001). There was good intraobserver reliability and agreement. Repeatability coefficient ranged between 4.4 degrees (3.7-4.9 degrees) and 3.4 degrees (2.9-3.8 degrees), the ICC between 0.87 (0.83-0.91) and 0.93 (0.90-0.95) and the standard deviation ranged between 1.3 and 1.0 degrees. Conclusions The present study demonstrated that TKA affected the estimation of FFA only in the frontal plane. This method reported good repeatability, demonstrating its usefulness for clinical purposes particularly to evaluate rotational positioning of the femoral component in the axial plane.
引用
收藏
页码:694 / 702
页数:9
相关论文
共 46 条
  • [1] Rotational Position of Femoral and Tibial Components in TKA Using the Femoral Transepicondylar Axis
    Aglietti, Paolo
    Sensi, Lorenzo
    Cuomo, Pierluigi
    Ciardullo, Antonio
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (11) : 2751 - 2755
  • [2] FEMORAL ROTATIONAL ALIGNMENT, BASED ON THE ANTEROPOSTERIOR AXIS, IN TOTAL KNEE ARTHROPLASTY IN A VALGUS KNEE - A TECHNICAL NOTE
    ARIMA, J
    WHITESIDE, LA
    MCCARTHY, DS
    WHITE, SE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (09) : 1331 - 1334
  • [3] The functional flexion-extension axis of the knee corresponds to the surgical epicondylar axis - In vivo analysis using a biplanar image-matching technique
    Asano, T
    Akagi, M
    Nakamura, T
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (08) : 1060 - 1067
  • [4] In vivo three-dimensional patellar tracking on the femur
    Asano, T
    Akagi, M
    Koike, K
    Nakamura, T
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (413) : 222 - 232
  • [5] Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables
    Bartlett, J. W.
    Frost, C.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (04) : 466 - 475
  • [6] BERGER RA, 1993, CLIN ORTHOP RELAT R, P40
  • [7] HELICAL AXES OF PASSIVE KNEE-JOINT MOTIONS
    BLANKEVOORT, L
    HUISKES, R
    DELANGE, A
    [J]. JOURNAL OF BIOMECHANICS, 1990, 23 (12) : 1219 - 1229
  • [8] Intraoperative evaluation of total knee replacement: kinematic assessment with a navigation system
    Casino, Daniela
    Zaffagnini, Stefano
    Martelli, Sandra
    Lopomo, Nicola
    Bignozzi, Simone
    Iacono, Francesco
    Russo, Alessandro
    Marcacci, Maurilio
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (04) : 369 - 373
  • [9] Churchill DL, 1998, CLIN ORTHOP RELAT R, P111
  • [10] APPLICATION OF THE JOINT COORDINATE SYSTEM TO 3-DIMENSIONAL JOINT ATTITUDE AND MOVEMENT REPRESENTATION - A STANDARDIZATION PROPOSAL
    COLE, GK
    NIGG, BM
    RONSKY, JL
    YEADON, MR
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04): : 344 - 349