Comparison of superconducting fault current limiter in power system

被引:0
|
作者
Yu, S [1 ]
Shi, DY [1 ]
Duan, XZ [1 ]
Tang, YJ [1 ]
Cheng, SJ [1 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Elect Power Engn, Wuhan 430074, Hubei, Peoples R China
关键词
SFCL; workino current; quench current; equivalent fundamental frequency impedance; response time;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to its ideal electrical behavior, Superconducting Fault Current Limiter (SFCL) becomes one of the most important developing trends of limiters in power system. This paper summarizes the main electrical behaviors of SFCL, including the relationship between SFCL's working current and quench current of superconducting coil(SC), and the relationship between equivalent fundamental frequency impedance of SFCL and normal state resistance of SC. Operation losses and response time of SFCL are also discussed. it analyzes different influences of quench type SFCL and non-quench type SFCL on waveform and total harmonic distortion (THD) of line current and node measurement impedance. Electro-magnetic simulation is adopted to analyze characteristics of SFCL.
引用
收藏
页码:43 / 47
页数:3
相关论文
共 50 条
  • [31] Application study of a high-temperature superconducting fault current limiter for electric power system
    Shimizu, I
    Naito, Y
    Yamaguchi, I
    Kaiho, K
    Yanabu, S
    ELECTRICAL ENGINEERING IN JAPAN, 2006, 155 (04) : 20 - 29
  • [32] Application study of a high-temperature superconducting fault current limiter for electric power system
    Shimizu, Iwao
    Naito, Yuji
    Yamaguchi, Iwao
    Kaiho, Katsuyuki
    Yanabu, Satoru
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 2006, 155 (04): : 20 - 29
  • [33] Repetitive operation of three-phase superconducting fault current limiter in a model power system
    Shirai, Y
    Mochida, A
    Morimoto, T
    Shiotsu, M
    Oide, T
    Chiba, M
    Nitta, T
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) : 2110 - 2113
  • [34] Method of Recloser-Fuse Coordination in a Power Distribution System With Superconducting Fault Current Limiter
    Kim, M. H.
    Lim, S. H.
    Moon, J. F.
    Kim, J. C.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 1164 - 1167
  • [35] Operational Characteristics of Three-Phase Active Superconducting Fault Current Limiter in Power System
    Chen, Lei
    Tang, Yuejin
    Chen, Nan
    Shi, Jing
    Song, Meng
    Cheng, Shijie
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 4455 - 4459
  • [36] Application of resistor based superconducting fault current limiter to enhancement of power system transient stability
    Tsuda, M
    Mitani, Y
    Tsuji, K
    Kakihana, K
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 2122 - 2125
  • [37] A Study on the Application of a Superconducting Fault Current Limiter for Energy Storage Protection in a Power Distribution System
    Moon, Won-Sik
    Won, Jong-Nam
    Huh, Jae-Sun
    Kim, Jae-Chul
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
  • [38] Characteristic Comparison of the Superconducting Fault Current Limiter With Various Bypass Reactors
    Chang, Ki Sung
    Park, Dong Keun
    Yang, Seong Eun
    Kim, Young Jae
    Chu, Sung Yul
    Ahn, Min Cheol
    Ko, Tae Kuk
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 1190 - 1193
  • [39] The Mechanism Analysis of Fault Current Limiter on Power System
    Sun Shou-wen
    Hu Xi-tong
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [40] System Study of Fault Current Limiter for Shipboard Power System
    Diaz, Bart
    Ortmeyer, Thomas H.
    Pilvelait, Bruce
    Izenson, Mike
    Chen, Weibo
    Spivey, Nathan
    2009 IEEE ELECTRIC SHIP TECHNOLOGIES SYMPOSIUM, 2009, : 376 - +