Comparison of superconducting fault current limiter in power system

被引:0
|
作者
Yu, S [1 ]
Shi, DY [1 ]
Duan, XZ [1 ]
Tang, YJ [1 ]
Cheng, SJ [1 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Elect Power Engn, Wuhan 430074, Hubei, Peoples R China
关键词
SFCL; workino current; quench current; equivalent fundamental frequency impedance; response time;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to its ideal electrical behavior, Superconducting Fault Current Limiter (SFCL) becomes one of the most important developing trends of limiters in power system. This paper summarizes the main electrical behaviors of SFCL, including the relationship between SFCL's working current and quench current of superconducting coil(SC), and the relationship between equivalent fundamental frequency impedance of SFCL and normal state resistance of SC. Operation losses and response time of SFCL are also discussed. it analyzes different influences of quench type SFCL and non-quench type SFCL on waveform and total harmonic distortion (THD) of line current and node measurement impedance. Electro-magnetic simulation is adopted to analyze characteristics of SFCL.
引用
收藏
页码:43 / 47
页数:3
相关论文
共 50 条
  • [1] Superconducting Fault Current Limiter for the Electric Power System
    Majka, M.
    Kozak, J.
    ACTA PHYSICA POLONICA A, 2016, 130 (02) : 581 - 584
  • [2] Power system stability improvement with superconducting fault current limiter
    Didier, Gaetan
    Bonnard, Charles Henri
    Douine, Bruno
    Leveque, Jean
    2014 INTERNATIONAL CONFERENCE ON ELECTRICAL SCIENCES AND TECHNOLOGIES IN MAGHREB (CISTEM), 2014,
  • [3] Improvement of power system transient stability by superconducting fault current limiter
    Yagami, M
    Shibata, S
    Murata, T
    Tamura, J
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 359 - 364
  • [4] Stability analysis of a power system with superconducting fault current limiter installed
    Lee, S
    Lee, C
    Ko, TK
    Hyun, O
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 2098 - 2101
  • [5] Superconducting Fault Current Limiter for Grid Connected Power System Protection
    Naresh, Maloth
    Singh, Navneet Kumar
    Singh, Asheesh Kumar
    PROCEEDINGS 2016 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2016, : 576 - 581
  • [6] Application study of different superconducting fault current limiter in power system
    Yu, J.
    Duan, X.
    He, Y.
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 2001, 25 (12): : 42 - 44
  • [7] Comparison of Superconducting Fault Current Limiter Topologies Based on Power Electronic Devices
    Kumar, Punith
    Shaw, Priyabrata
    2016 7TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE), 2016,
  • [8] A Superconducting Fault Current Limiter with a Power of 16 MV A
    Fisher L.M.
    Alferov D.F.
    Budovskiy A.I.
    Voloshin I.F.
    Evsin D.V.
    Kalinov A.V.
    Kuznetsova M.P.
    Rachitskiy D.G.
    Tskhai E.V.
    Russian Electrical Engineering, 2019, 90 (02) : 125 - 129
  • [9] Superconducting fault current limiter applications in electric power systems
    Ye, Lin
    Lin, Liangzhen
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2000, 20 (07): : 1 - 4
  • [10] Effects of Superconducting Fault Current Limiter on Power Distribution Systems
    Pei, Zhengjiang
    He, Junjia
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 2277 - 2281