Comparison of Neurologic and Radiographic Outcomes with Solitaire versus Merci/Penumbra Systems for Acute Stroke Intervention

被引:13
作者
Hann, Shannon [1 ,2 ]
Chalouhi, Nohra [1 ,2 ]
Starke, Robert [1 ,2 ]
Gandhe, Ashish [2 ,3 ]
Koltz, Michael [1 ,2 ]
Theofanis, Thana [1 ,2 ]
Jabbour, Pascal [1 ,2 ]
Gonzalez, L. Fernando [1 ,2 ]
Rosenwasser, Robert [1 ,2 ]
Tjoumakaris, Stavropoula [1 ,2 ]
机构
[1] Thomas Jefferson Univ, Dept Neurosurg, Philadelphia, PA 19107 USA
[2] Jefferson Hosp Neurosci, Philadelphia, PA 19107 USA
[3] Thomas Jefferson Univ, Dept Radiol, Philadelphia, PA 19107 USA
关键词
ISCHEMIC-STROKE; MERCI; OCCLUSIONS;
D O I
10.1155/2013/715170
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background and Purpose. The Solitaire Flow Restoration was approved by the FDA in 2012 for mechanical thrombolysis of proximal occlusion of intracranial arteries. To compare the Solitaire FR device and the Merci/Penumbra (previously FDA approved) systems in terms of safety, clinical outcomes, and efficacy including radiographic brain parenchymal salvage. Methods. Thirty-one consecutive patients treated with the Solitaire and 20 patients with comparable baseline characteristics treated with Merci or Penumbra systems were included in the study. Primary outcome measures included recanalization rate and modified Rankin Scale score at followup. Secondary outcomes included length of procedure, incidence of symptomatic intracranial hemorrhage, 90-day mortality, and radiographic analysis of percentage area salvage. Results. Compared with the Merci/Penumbra group, the Solitaire group showed a statistically significant improvement in favorable outcomes (mRS <= 2) (69% versus 35%, P = 0.03) and symptomatic ICH rate (0 versus 15%, P = 0.05) with a trend towards higher recanalization rates (93.5% versus 75%, P = 0.096) and shorter length of procedure (58.5 min versus 70.8 min, P = 0.08). Radiographic comparison also showed a significantly larger area of salvage in the Solitaire group (81.9% versus 71.9%, P = 0.05). Conclusion. Our study suggests that the Solitaire system allows faster, safer, and more efficient thrombectomy than Merci or Penumbra systems.
引用
收藏
页数:9
相关论文
共 9 条
[1]   Guidelines for the early management of adults with ischemic stroke - A guideline from the American Heart Association/American Stroke Association Stroke Council, Clinical Cardiology Council, Cardiovascular Radiology and Intervention Council, and the atherosclerotic peripheral vascular disease and quality of care outcomes in research interdisciplinary working groups [J].
Adams, Harold P., Jr. ;
del Zoppo, Gregory ;
Alberts, Mark J. ;
Bhatt, Deepak L. ;
Brass, Lawrence ;
Furlan, Anthony ;
Grubb, Robert L. ;
Higashida, Randall T. ;
Jauch, Edward C. ;
Kidwell, Chelsea ;
Lyden, Patrick D. ;
Morgenstern, Lewis B. ;
Qureshi, Adnan I. ;
Rosenwasser, Robert H. ;
Scott, Phillip A. ;
Wijdicks, Eelco F. M. .
STROKE, 2007, 38 (05) :1655-1711
[2]  
Chalouhi N., 2013, CLIN NEUROLOGY NEURO
[3]  
Chalouhi N., 2011, NEUROSURGICAL FOCUS, V35
[4]   Higher Degrees of Recanalization after Mechanical Thrombectomy for Acute Stroke Are Associated with Improved Outcome and Decreased Mortality: Pooled Analysis of the MERCI and Multi MERCI Trials [J].
Fields, J. D. ;
Lutsep, H. L. ;
Smith, W. S. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (11) :2170-2174
[5]   The Penumbra Pivotal Stroke Trial Safety and Effectiveness of a New Generation of Mechanical Devices for Clot Removal in Intracranial Large Vessel Occlusive Disease [J].
Langer, David ;
Alexander, Michael ;
Janardhan, Vallabh ;
Hartmann, Marius ;
Jansen, Olav ;
Sit, Siu Po ;
Yavagal, Dileep ;
Stingele, Robert ;
DeMuth, George ;
Bose, Arani ;
Clark, Wayne ;
Lutsep, Helmi ;
Barnwell, Stanley ;
Nesbit, Gary ;
Egan, Robert ;
North, Elizabeth ;
Yanase, Lisa ;
Lowenkopf, Ted ;
Petersen, Bryan ;
Grunwald, Iris Quasar ;
Mayer, Thomas ;
Doerfler, Arnd ;
Struffert, Tobias ;
Engelhorn, Tobias ;
Richter, Gregor ;
Grunwald, Iris Quasar ;
Reith, Wolfgang ;
Berkefeld, Joachim ;
Madison, Michael ;
Myers, Mark ;
Goddard, James ;
Lassig, Jeffrey ;
Lopes, Demetrius ;
Shownkeen, Harish ;
Echiverri, Henry ;
Nour, Fred ;
Mazumdar, Avi ;
Budzik, Ronald ;
Pema, Peter ;
Frei, Don ;
Huddle, Daniel ;
Bellon, Richard ;
Heck, Donald ;
Ferguson, Robert ;
McDougall, Cameron ;
Flaster, Murray ;
Frey, James ;
Albuquerque, Felipe ;
Malkoff, Marc ;
Zaidat, Osama .
STROKE, 2009, 40 (08) :2761-2768
[6]   Trevo versus Merci retrievers for thrombectomy revascularisation of large vessel occlusions in acute ischaemic stroke (TREVO 2): a randomised trial [J].
Nogueira, Raul G. ;
Lutsep, Helmi L. ;
Gupta, Rishi ;
Jovin, Tudor G. ;
Albers, Gregory W. ;
Walker, Gary A. ;
Liebeskind, David S. ;
Smith, Wade S. .
LANCET, 2012, 380 (9849) :1231-1240
[7]   Solitaire flow restoration device versus the Merci Retriever in patients with acute ischaemic stroke (SWIFT): a randomised, parallel-group, non-inferiority trial [J].
Saver, Jeffrey L. ;
Jahan, Reza ;
Levy, Elad I. ;
Jovin, Tudor G. ;
Baxter, Blaise ;
Nogueira, Raul G. ;
Clark, Wayne ;
Budzik, Ronald ;
Zaidat, Osama O. .
LANCET, 2012, 380 (9849) :1241-1249
[8]   Clinical Outcomes in Middle Cerebral Artery Trunk Occlusions Versus Secondary Division Occlusions After Mechanical Thrombectomy Pooled Analysis of the Mechanical Embolus Removal in Cerebral Ischemia (MERCI) and Multi MERCI Trials [J].
Shi, Zhong-Song ;
Loh, Yince ;
Walker, Gary ;
Duckwiler, Gary R. .
STROKE, 2010, 41 (05) :953-960
[9]   Mechanical Clot Retrieval in the Treatment of Acute Ischemic Stroke [J].
Starke, Robert M. ;
Komotar, Ricardo J. ;
Connolly, E. Sander .
NEUROSURGERY, 2013, 72 (02) :N19-N21