Accuracy of cup orientation and learning curve of the accelerometer-based portable navigation system for total hip arthroplasty in the supine position

被引:33
作者
Kamenaga, Tomoyuki [1 ]
Hayashi, Shinya [1 ]
Hashimoto, Shingo [1 ]
Matsumoto, Tomoyuki [1 ]
Takayama, Koji [1 ]
Fujishiro, Takaaki [2 ]
Hiranaka, Takafumi [2 ]
Niikura, Takahiro [1 ]
Kuroda, Ryosuke [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Orthopaed Surg, Kobe, Hyogo, Japan
[2] Takatsuki Gen Hosp, Dept Orthopaed Surg, Osaka, Japan
关键词
cup orientation; learning curve; navigation; total hip arthroplasty; COMPUTER-ASSISTED NAVIGATION; CONSECUTIVE SERIES; ACETABULAR CUP; IMAGELESS NAVIGATION; SURGICAL APPROACH; ANTERIOR APPROACH; TIBIAL RESECTION; DISLOCATIONS; REPLACEMENT; PLACEMENT;
D O I
10.1177/2309499019848871
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To assess the accuracy of cup orientation and learning curve of the disposable accelerometer-based portable navigation system for total hip arthroplasty (THA) in the supine position. Methods: A total of 75 patients who underwent THA through the anterolateral supine approach (ALS) with an accelerometer-based portable navigation system for the supine position (HipAlignA (R)) between July 2017 and October 2018 were analyzed in this study. We compared the intraoperative cup angles using navigation records with the postoperative angles using postoperative computed tomography (CT) data. All patients were categorized into the following groups according to the course of three discrete, sequential operative time periods: 1-25 (initial group), 26-50 (intermediate group), and 51-75 (recent group). We compared the accuracy of cup inclination and anteversion among the three groups. The time required for navigation and the operative time of all patients were measured. Results: The average absolute error in measurement (postoperative CT-navigation record) was 2.6 degrees +/- 2.7 degrees (inclination) and 2.8 degrees +/- 2.7 degrees (anteversion). There were no significant differences among the three groups. The average time required for navigation and the operative time were 365.1 +/- 90.3 s and 76.1 +/- 1.6 min, respectively. The required time for HipAlignA (R) navigation and operative time were constant in most patients, except for those of the initial five cases. Conclusion: The accelerometer-based portable navigation system provides good accuracy of cup orientation, has a short learning curve, and requires a minimal surgical time for THA in supine position.
引用
收藏
页数:6
相关论文
共 30 条
[1]   Patient Obesity Influences Pelvic Lift During Cup Insertion in Total Hip Arthroplasty Through a Lateral Transgluteal Approach in Supine Position [J].
Brodt, Steffen ;
Nowack, Dimitri ;
Jacob, Benjamin ;
Krakow, Linda ;
Windisch, Christoph ;
Matziolis, Georg .
JOURNAL OF ARTHROPLASTY, 2017, 32 (09) :2762-2767
[2]   Surgical approach and prosthesis fixation in hip arthroplasty world wide [J].
Chechik, Ofir ;
Khashan, Morsi ;
Lador, Ran ;
Salai, Moshe ;
Amar, Eyal .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (11) :1595-1600
[3]   Combined Anteversion Technique for Total Hip Arthroplasty [J].
Dorr, Lawrence D. ;
Malik, Aamer ;
Dastane, Manish ;
Wan, Zhinian .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) :119-127
[4]   Computer navigation in total hip replacement: a meta-analysis [J].
Gandhi, Rajiv ;
Marchie, Anthony ;
Farrokhyar, Forough ;
Mahomed, Nizar .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (03) :593-597
[5]   Comparison of Cup Alignment, Jump Distance, and Complications in Consecutive Series of Anterior Approach and Posterior Approach Total Hip Arthroplasty [J].
Hamilton, William G. ;
Parks, Nancy L. ;
Huynh, Cathy .
JOURNAL OF ARTHROPLASTY, 2015, 30 (11) :1959-1962
[6]   Clinical and radiographic outcomes of an accelerometer-based system for the tibial resection in total knee arthroplasty [J].
Iorio, Raffaele ;
Mazza, Daniele ;
Drogo, Piergiorgio ;
Bolle, Gabriele ;
Conteduca, Fabio ;
Redler, Andrea ;
Valeo, Luigi ;
Conteduca, Jacopo ;
Ferretti, Andrea .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (03) :461-466
[7]   Greater accuracy in positioning of the acetabular cup by using an image-free navigation system [J].
Kalteis, T ;
Handel, M ;
Herold, T ;
Perlick, L ;
Baethis, H ;
Grifka, J .
INTERNATIONAL ORTHOPAEDICS, 2005, 29 (05) :272-276
[8]   Does the surgical approach influence the implant alignment in total hip arthroplasty? Comparative study between the direct anterior and the anterolateral approaches in the supine position [J].
Kawarai, Yuya ;
Iida, Satoshi ;
Nakamura, Junichi ;
Shinada, Yoshiyuki ;
Suzuki, Chiho ;
Ohtori, Seiji .
INTERNATIONAL ORTHOPAEDICS, 2017, 41 (12) :2487-2493
[9]   Is There Faster Recovery With an Anterior or Anterolateral THA? A Pilot Study [J].
Klausmeier, Virginia ;
Lugade, Vipul ;
Jewett, Brian A. ;
Collis, Dennis K. ;
Chou, Li-Shan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) :533-541
[10]   Total Hip Arthroplasty Using Imageless Computer-Assisted Hip Navigation A Prospective Randomized Study [J].
Lass, Richard ;
Kubista, Bernd ;
Olischar, Boris ;
Frantal, Sophie ;
Windhager, Reinhard ;
Giurea, Alexander .
JOURNAL OF ARTHROPLASTY, 2014, 29 (04) :786-791