Assessment of a new distance randot stereoacuity test

被引:39
作者
Fu, Valeria L. N.
Birch, Eileen E.
Holmes, Jonathan M.
机构
[1] Retina Fdn SW, Dallas, TX 75231 USA
[2] Univ Texas, Med Ctr, Dept Ophthalmol, Dallas, TX 75230 USA
[3] Mayo Clin Rochester, Coll Med, Dept Ophthalmol, Rochester, MN USA
来源
JOURNAL OF AAPOS | 2006年 / 10卷 / 05期
关键词
D O I
10.1016/j.jaapos.2006.06.013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE We sought to develop a new "Distance Randot" test, establish a normative data set for children and adults, and compare with established measures of stereoacuity. METHODS Distance Randot, distance Frisby-Davis 2 (FD2), and near Preschool Randot stereoacuity (Stereo Optical Co., Inc., Chicago, IL) were assessed in 23 normal children (ages 4-14 years), 21 normal adults (ages 20-36 years), and 131 patients with a variety of strabismic conditions (ages 4-85 years). For each test, stereoacuity was defined as the smallest disparity in which 2 targets were correctly identified. The simultaneous prism and cover test (SPCT) and the alternate prism and cover test (APCT) were used to assess misalignment. RESULTS For the new Distance Randot test, normative results were similar to published data obtained with established near and distance stereoacuity tests. In the patient cohort, comparing stereoacuity data obtained from Distance Randot stereoacuity test and the Near Preschool Randot stereoacuity test, most of the patients with discordant scores had poorer distance than near stereoacuity. Comparing the Distance Randot stereoacuity test and the Distance FD2, all of the patients with discordant scores had poorer Distance Randot than FD2 scores. CONCLUSIONS Distance Randot test is more likely to detect abnormalities in distance stereopsis and may provide a useful tool in measuring distance stereoacuity in patients with and without strabismus. However, further studies are needed to define the efficacy of the Distance Randot test in monitoring progression specific conditions such as intermittent exotropia, where it may prove useful as a guide to the timing of intervention.
引用
收藏
页码:419 / 423
页数:5
相关论文
共 14 条
[1]   PRESCHOOL VISION STUDY [J].
AMIGO, G .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1973, 57 (02) :125-132
[2]   A computerized method of visual acuity testing: Adaptation of the early treatment of diabetic retinopathy study testing protocol [J].
Beck, RW ;
Moke, PS ;
Turpin, AH ;
Ferris, FL ;
Sangiovanni, JP ;
Johnson, CA ;
Birch, EE ;
Chandler, DL ;
Cox, TA ;
Blair, RC ;
Kraker, RT .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (02) :194-205
[3]  
Birch E, 1997, J PEDIAT OPHTH STRAB, V34, P217
[4]   Interobserver test-retest reliability of the randot preschool stereoacuity test [J].
Fawcett, SL ;
Birch, EE .
JOURNAL OF AAPOS, 2000, 4 (06) :354-358
[5]  
HERON G, 1985, AM J OPTOM PHYS OPT, V62, P505
[6]   Testing distance stereoacuity with the Frisby-Davis 2 (FD2) test [J].
Holmes, JM ;
Fawcett, SL .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (01) :193-195
[7]  
Holmes JM, 2001, ARCH OPHTHALMOL-CHIC, V119, P1345
[8]  
MARSH WR, 1980, OPHTHALMOLOGY, V87, P1265
[9]   Computerized method of visual acuity testing: Adaptation of the amblyopia treatment study visual acuity testing protocol [J].
Moke, PS ;
Turpin, AH ;
Beck, RW ;
Holmes, JM ;
Repka, MX ;
Birch, EE ;
Hertle, RW ;
Kraker, RT ;
Miller, JM ;
Johnson, CA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2001, 132 (06) :903-909
[10]   NEW STEREOSCOPIC TEST FOR AMBLYOPIA SCREENING [J].
REINECKE, RD ;
SIMONS, K .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1974, 78 (04) :714-721