Short- and Long-term Results of Glaucoma Valve Implantation for Aniridia-related Glaucoma: A Case Series and Literature Review

被引:9
|
作者
Demirok, Gulizar Soyugelen [1 ]
Eksioglu, Umit [1 ]
Yakin, Mehmet [1 ]
Kaderli, Ahmet [1 ]
Kaderli, Sema Tamer [1 ]
Ornek, Firdevs [1 ]
机构
[1] Ankara Numune Training & Res Hosp, Ophthalmol Clin, Ankara, Turkey
来源
TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY | 2019年 / 49卷 / 04期
关键词
Aniridia-related glaucoma; congenital aniridia; glaucoma; glaucoma drainage devices; MANAGEMENT; SECONDARY;
D O I
10.4274/tjo.galenos.2019.07348
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To report the results obtained from glaucoma drainage device (GDD) implantation in patients with aniridia-related glaucoma and to review the literature. Materials and Methods: We retrospectively reviewed 6 patients who underwent GDD implantation for glaucoma secondary to congenital aniridia between April 2001 and February 2015. Data on age at surgery, gender, laterality, surgeries before GDD implantation, GDD model, concomitant ocular disorders, visual acuity, and intraocular pressure (IOP) values before and at 1 and 12 months after GDD implantation, medications, follow-up period, findings during last visit, complications, and course of disease were collected. Results: Mean age at surgery was 16.00 +/- 12.31 years (range 5-37 years). Mean IOP was 33.00 +/- 12.11 (range 22-50) mm Hg just before the GDD implantation with a mean of 3.5 +/- 1.2 medications. Mean IOP 1 month after implantation was 16.33 +/- 4.22 (range 12-24) mm Hg with a mean of 1.5 +/- 0.8 medications; at 12 months, mean IOP was 19.50 +/- 4.76 (range 15-26) mm Hg with 3.0 +/- 0.8 medications. At the last follow-up visit, IOP was 21.16 +/- 4.07 (range 16-26) mmHg with a mean of 3.33 +/- 0.51 medications. Mean follow-up was 19.16 +/- 8.8 (range 12-36) months. Surgical success rates were 83.3%, 66.6%, and 50.0% at 1 month, 12 months, and the last visit, respectively. Conclusion: GDD implantation was effective in controlling aniridic glaucoma with a success rate of 83.3% at 1-month follow-up and 66.6% at 1-year follow-up. Therefore, it should be considered as an initial surgical treatment for aniridic glaucoma; the clinician should be alert for concomitant ocular disorders.
引用
收藏
页码:183 / 187
页数:5
相关论文
共 50 条
  • [11] The effect of the hypertensive phase on the long-term outcomes of Ahmed glaucoma valve (AGV) implantation
    Naveed Nilforushan
    Kiana Hassanpour
    Fatemeh Vafaei
    Maryam Yadgari
    International Ophthalmology, 2022, 42 : 3739 - 3747
  • [12] Diode laser cycloablation in adult glaucoma: long-term results of a standard protocol and review of current literature
    Vernon, Stephen A.
    Koppens, Joanne M.
    Menon, G. Jayakrishna
    Negi, Anil K.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (05) : 411 - 420
  • [13] Long-term outcomes of uveitic glaucoma treated with Ahmed valve implant in a series of Chinese patients
    Bao, Ning
    Jiang, Zheng-Xuan
    Coh, Paul
    Tao, Li-Ming
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (04) : 629 - 634
  • [14] Long-term results after artificial iris implantation in patients with aniridia
    Rickmann, Annekatrin
    Szurman, Peter
    Januschowski, Kai
    Waizel, Maria
    Spitzer, Martin S.
    Boden, Karl T.
    Szurman, Gesine B.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (07) : 1419 - 1424
  • [15] Ahmed glaucoma valve via pars plana access: Long-term results of implantation for therapy refractive glaucoma; [Ahmed Glaucoma Valve über Pars-plana-Zugang: Langzeitergebnisse von Implantationen bei therapierefraktärem Glaukom]
    Mazinani B.
    Schwarzer H.
    Willkomm A.
    Weinberger A.
    Plange N.
    Walter P.
    Rössler G.
    Der Ophthalmologe, 2013, 110 (6): : 537 - 542
  • [16] Short- and long-term agreement and reproducibility of 48-hours intraocular pressure measurements in glaucoma patients
    Zimmermann, Marion
    Giers, Bert C.
    Beck, Anna
    Bell, Katharina
    Zimmermann, Herwig
    Hechtner, Marlene
    Hoffmann, Esther M.
    Pfeiffer, Norbert
    Lorenz, Katrin
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [17] Short- and long-term agreement and reproducibility of 48-hours intraocular pressure measurements in glaucoma patients
    Marion Zimmermann
    Bert C. Giers
    Anna Beck
    Katharina Bell
    Herwig Zimmermann
    Marlene Hechtner
    Esther M. Hoffmann
    Norbert Pfeiffer
    Katrin Lorenz
    BMC Ophthalmology, 21
  • [18] Bleb Analysis and Short- Term Results of Biodegradable Collagen Matrix-Augmented Ahmed Glaucoma Valve Implantation: 6-Month Follow-up
    Rho, Seungsoo
    Sung, Youngje
    Ma, Kyoung Tak
    Rho, Sae Heun
    Kim, Chan Yun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (10) : 5896 - 5903
  • [19] Long-term Outcome of Ahmed Glaucoma Valve Implantation in Eyes With Intractably Raised Intraocular Pressure Following Pars Plana Vitrectomy
    Pandav, Surinder S.
    Thattaruthody, Faisal
    Singh, Simar R.
    Chandra, Kedarisetti K.
    Seth, Natasha G.
    Kaur, Savleen
    Kaushik, Sushmita
    Raj, Srishti
    JOURNAL OF GLAUCOMA, 2021, 30 (04) : 362 - 367
  • [20] Long-term results of ab externo trabeculotomy for glaucoma secondary to chronic uveitis
    Voykov, Bogomil
    Dimopoulos, Spyridon
    Leitritz, Martin Alexander
    Doycheva, Deshka
    William, Antony
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (02) : 355 - 360