Self-Expanding Nitinol Stent Implantation for Treatment of Aortic Coarctation

被引:19
作者
Haji-Zeinali, Ali-Mohammad [1 ]
Ghazi, Payam [2 ]
Alidoosti, Mohammad [1 ]
机构
[1] Univ Tehran Med Sci, Dept Intervent Cardiol, Tehran Heart Ctr, Tehran, Iran
[2] Univ Tehran Med Sci, Res Unit, Tehran Heart Ctr, Tehran, Iran
关键词
aorta; coarctation; coarctoplasty; nitinol stent; self-expanding stent; Sinus-Aorta stent; TERM FOLLOW-UP; NATIVE COARCTATION; BALLOON ANGIOPLASTY; ENDOVASCULAR STENTS; RECURRENT COARCTATION; COVERED STENTS; LONG-TERM; MANAGEMENT; ADOLESCENTS; ADULT;
D O I
10.1583/08-2589.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To prospectively assess the efficacy of self-expanding nitinol aortic stents in the treatment of coarctation of the aorta (CoA). Methods: Between July 2005 and July 2008, 21 patients (14 men; mean age 19.2 +/- 5.5 years, range 11-34) with CoA were treated with self-expanding Sinus-Aorta stents. The predilation balloon was selected to be <5 times the stenosis diameter. The stent diameter was selected to be 20% to 30% greater than the diameter of the undiseased aorta at the level of the diaphragm. Results:All procedures were successfully performed without any major complications. Predilation (mean balloon diameter 12.3 mm) and postdilation (mean balloon diameter 15.4 mm) were performed in 12 and 14 procedures, respectively. The mean diameter of the stents was 21.6 +/- 2.3 mm (range 18-26). The mean peak transcoarctation pressure gradient decreased from 57.4 +/- 19.5 mmHg (range 30-100) before the procedure to 1.2 +/- 2.2 mmHg (range 0-7; p<0.001). Cephalad stent dislodgement with the first-generation device occurred in 3 of 12 patients; 2 were treated with a second stent overlapping the first, and the third received 3 overlapped stents after the second stent migrated distally. No stent dislodgement occurred in the subsequent 9 patients treated with longer second-generation stents with anti-jump markers. None of the patients had dissection, arterial rupture, or other complications. On follow-up, 1 (5%) patient had recoarctation and minor stent migration after 18 months; another stent was deployed successfully. No evidence of aneurysm formation was seen in 7 patients undergoing arch imaging. Conclusion: CoA can be successfully and safely managed with self-expanding nitinol aortic stents without aortic wall complications. Stent malpositioning can be overcome using oversized stents with anti-jump markers. J Endovasc Ther. 2009;16:224-232
引用
收藏
页码:224 / 232
页数:9
相关论文
共 33 条
  • [1] Stress stent fracture:: Is stent angioplasty really a safe therapeutic option in native aortic coarctation?
    Carrozza, Marianna
    Santoro, Giuseppe
    Giovanna Russo, Maria
    Caianiello, Giuseppe
    Calabro, Raffaele
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 113 (01) : 127 - 128
  • [2] Stenting of coarctation of the aorta
    Cheatham, JP
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (01) : 112 - 125
  • [3] Results and mid-long-term follow-up of stent implantation for native and recurrent coarctation of the aorta
    Chessa, M
    Carrozza, M
    Butera, G
    Piazza, L
    Negura, DG
    Bussadori, C
    Bossone, E
    Giamberti, A
    Carminati, M
    [J]. EUROPEAN HEART JOURNAL, 2005, 26 (24) : 2728 - 2732
  • [4] Long-term, randomized comparison of balloon angioplasty and surgery for native coarctation of the aorta in childhood
    Cowley, CG
    Orsmond, GS
    Feola, P
    McQuillan, L
    Shaddy, RE
    [J]. CIRCULATION, 2005, 111 (25) : 3453 - 3456
  • [5] de Lezo JS, 1999, AM J CARDIOL, V83, P400
  • [6] One- to ten-year follow-up results of balloon angioplasty of native coarctation of the aorta in adolescents and adults
    Fawzy, ME
    Sivanandam, V
    Galal, O
    Dunn, B
    Patel, A
    Rifai, A
    vonSinner, W
    AlHalees, Z
    Khan, B
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (06) : 1542 - 1546
  • [7] Fatal dissection of the descending aorta after implantation of a stent in a 19-year-old female with Turner's syndrome
    Fejzic, Z
    van Oort, A
    [J]. CARDIOLOGY IN THE YOUNG, 2005, 15 (05) : 529 - 531
  • [8] BALLOON ANGIOPLASTY OF NATIVE COARCTATION OF THE AORTA - MIDTERM FOLLOW-UP AND PROGNOSTIC FACTORS
    FLETCHER, SE
    NIHILL, MR
    GRIFKA, RG
    OLAUGHLIN, MP
    MULLINS, CE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (03) : 730 - 734
  • [9] Intermediate follow-up following intravascular stenting for treatment of coarctation of the aorta
    Forbes, Thomas J.
    Moore, Phillip
    Pedra, Carlos A. C.
    Zahn, Evan M.
    Nykanen, David
    Amin, Zahid
    Garekar, Swati
    Teitel, David
    Qureshi, Shakeel A.
    Cheatham, John P.
    Ebeid, Makram R.
    Hijazi, Ziyad M.
    Sandhu, Satinder
    Hagler, Donald J.
    Sievert, Horst
    Fagan, Thomas E.
    Ringwald, Jeremy
    Du, Wei
    Tang, Liwen
    Wax, David F.
    Rhodes, John
    Johnston, Troy A.
    Jones, Thomas K.
    Turner, Daniel R.
    Pass, Robert
    Torres, Alejandro
    Hellenbrand, William E.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (04) : 569 - 577
  • [10] Procedural results and acute complications in stenting native and recurrent coarctation of the aorta in patients over 4 years of age: A multi-institutional study
    Forbes, Thomas J.
    Garekar, Swati
    Amin, Zahid
    Zahn, Evan M.
    Nykanen, David
    Moore, Phillip
    Qureshi, Shakeel A.
    Cheatham, John P.
    Ebeid, Makram R.
    Hijazi, Ziyad M.
    Sandhu, Satinder
    Hagler, Donald J.
    Sievert, Horst
    Fagan, Thomas E.
    Ringewald, Jeremy
    Du, Wei
    Tang, Liwen
    Wax, David F.
    Rhodes, John
    Johnston, Troy A.
    Jones, Thomas K.
    Turner, Daniel R.
    Pedra, Carlos A. C.
    Hellenbrand, William E.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (02) : 276 - 285