Novel Ionophore for the Potentiometric Determination of Cetirizine Hydrochloride in Pharmaceutical Formulations and Human Urine

被引:0
作者
Rizk, Nashwa M. H. [1 ]
Abbas, Samah S. [2 ]
El-Sayed, Fathy A. [3 ]
Abo-Bakr, Ahmed [3 ]
机构
[1] Menoufia Univ, Environm Biotechnol Dept, GEBRI, Sadat City, Egypt
[2] Cairo Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Cairo, Egypt
[3] Menoufia Univ, Dept Chem, Fac Sci, Sadat City, Egypt
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2009年 / 4卷 / 03期
关键词
Cetirizine; sensors; potentiometry; -cyclodextrin; carbon paste electrodes; human urine; pharmaceutical formulation; ION-SELECTIVE ELECTRODES; CARBON-PASTE ELECTRODE; DOSAGE FORMS; SPECTROPHOTOMETRIC DETERMINATION; MEMBRANE ELECTRODES; PLASTIC MEMBRANE; TECHNICAL REPORT; SENSORS; DIHYDROCHLORIDE; CYCLODEXTRIN;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Cetirizine (CT) membrane sensors of conventional (CE) and carbon paste (CPE) have been prepared, based on -cyclodextrin ( CD) as ionophore and potassium tetrakis[3,5-bis(trifluoro-methyl) phenyl] borate (KTFPB) as anionic membrane additive. The sensors exhibit a linear response with a mean calibration graph slopes of 60.2 and 57.4 mV per decade at 25 C for conventional and carbon paste electrodes, respectively, with the concentration ranges 1x10(-1)-5x10(-6) M for conventional and 1x10(-1)-7x10(-6) M for carbon paste. The electrodes fully characterized in terms of composition, usable pH range, life span and response time. The electrodes showed a very good selectivity for CT with respect to some inorganic and organic cations and other related compounds. Use of the sensors for the assay of formulation of CT drug and in spiked human urine, show a mean average recovery of 100.04 % and a mean precision of +/- 0.4. Significantly improved response time, stability, selectivity, accuracy, simple, and low cost are offered by potentiometric sensors compared with other standard methods.
引用
收藏
页码:396 / 406
页数:11
相关论文
共 33 条
  • [1] ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY
    BAKKER, E
    MALINOWSKA, E
    SCHILLER, RD
    MEYERHOFF, ME
    [J]. TALANTA, 1994, 41 (06) : 881 - 890
  • [2] GAS-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF CETIRIZINE IN PLASMA
    BALTES, E
    COUPEZ, R
    BROUWERS, L
    GOBERT, J
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 430 (01): : 149 - 155
  • [3] Spectrophotometric determination of ceterizine hydrochloride with Alizarin Red S
    Basavaiah, K
    SriLatha
    Swamy, JM
    [J]. TALANTA, 1999, 50 (04) : 887 - 892
  • [4] FUNCTIONALIZED CYCLODEXTRINS AS POTENTIOMETRIC SENSORS FOR ONIUM IONS
    BATES, PS
    KATAKY, R
    PARKER, D
    [J]. ANALYST, 1994, 119 (02) : 181 - 186
  • [5] Spectrophotometric and high performance liquid chromatographic determination of cetirizine dihydrochloride in pharmaceutical tablets
    El Walily, AFM
    Korany, MA
    El Gindy, A
    Bedair, MF
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (03) : 435 - 442
  • [6] Determination of cetirizine in human plasma by liquid chromatography-tandem mass spectrometry
    Eriksen, H
    Houghton, R
    Green, R
    Scarth, J
    [J]. CHROMATOGRAPHIA, 2002, 55 (Suppl 1) : S145 - S149
  • [7] THE PRODUCTION OF ALPHA-CYCLODEXTRIN BY ENZYMATIC DEGRADATION OF STARCH
    FLASCHEL, E
    LANDERT, JP
    SPIESSER, D
    RENKEN, A
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1984, 434 (DEC) : 70 - 77
  • [8] Determination of SCN- in urine and saliva of smokers and non-smokers by SCN--selective polymeric membrane containing a nickel(II)-azamacrocycle complex coated on a graphite electrode
    Ganjali, MR
    Yousefi, M
    Javanbakht, M
    Poursaberi, T
    Salavati-Niasari, M
    Hajiagha-Babaei, L
    Latifi, E
    Shamsipur, M
    [J]. ANALYTICAL SCIENCES, 2002, 18 (08) : 887 - 892
  • [9] Highly selective iodide membrane electrode based on a cerium salen
    Ganjali, MR
    Poursaberi, T
    Hosseini, M
    Salavati-Niasari, M
    Yousefi, M
    Shamsipur, M
    [J]. ANALYTICAL SCIENCES, 2002, 18 (03) : 289 - 292
  • [10] Determination of some histamine H1-receptor antagonists in dosage forms
    Gazy, AA
    Mahgoub, H
    El-Yazbi, FA
    El-Sayed, MA
    Youssef, RM
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) : 859 - 867