Highly efficient dynamic modification of plastic microfluidic devices using proteins in microchip capillary electrophoresis

被引:15
|
作者
Naruishi, Nahoko [1 ]
Tanaka, Yoshihide [1 ]
Higashi, Tetsuji [1 ]
Wakida, Shin-ichi [1 ]
机构
[1] Natl Inst AIST, HSS Res Ctr, Ikeda, Osaka 5638577, Japan
关键词
microchip capillary electrophoresis; poly(metheylmethacrylate) chip; dynamic coating; protein; EOF control;
D O I
10.1016/j.chroma.2006.07.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
New dynamic coating agents were investigated for the manipulation of electroosmotic flow (EOF) in poly(methylmethacrylate) (PMMA) microchips. Blocking proteins designed for enzyme-linked immunosorbent assay (ELISA) applications (e.g. Block Ace and UItraBlock), and egg-white lysozyme were proposed in this study. The EOF could be enhanced, suppressed or its direction could be reversed, depending on the buffer pH and the charge on the proteins. The coating procedure is simple, requiring only filling of the microchannels with a coating solution, followed by a rinse with a running buffer solution prior to analysis. One major advantage of this method is that it is not necessary to add the coating agent to the running buffer solution. Block Ace and UltraBlock coatings were stable for at least five runs in a given microchannel without the need to condition the coating between runs other than replenishing the buffer solution after each run, i.e. the RSD values of EOF (n = 5) were less than 4.3%, and there was no significant change in the EOF after 5 runs. The reproducibility of the coating procedures was found from the channel-to-channel RSD values of the EOF, and were less than 5.0% when using HEPES-Na buffer (pH 7.4) as the running buffer. Several examples of electrophoretic separations of amino acids and biogenic amines derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) are demonstrated in this paper. The dynamic coating method has the potential for a broad range of applications in microchip capillary electrophoresis (microchip CE) separations. (c) 2006 Elsevier B.V All rights reserved.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 42 条
  • [41] Highly Sensitive Analysis in Capillary Electrophoresis Using Large-volume Sample Stacking with an Electroosmotic Flow Pump Combined with Field-amplified Sample Injection
    Fumihiko Kitagawa
    Shinichiro Wakagi
    Yuuki Takegawa
    Isoshi Nukatsuka
    Analytical Sciences, 2019, 35 : 889 - 893
  • [42] Highly Sensitive Analysis in Capillary Electrophoresis Using Large-volume Sample Stacking with an Electroosmotic Flow Pump Combined with Field-amplified Sample Injection
    Kitagawa, Fumihiko
    Wakagi, Shinichiro
    Takegawa, Yuuki
    Nukatsuka, Isoshi
    ANALYTICAL SCIENCES, 2019, 35 (08) : 889 - 893