Highly efficient dynamic modification of plastic microfluidic devices using proteins in microchip capillary electrophoresis

被引:15
|
作者
Naruishi, Nahoko [1 ]
Tanaka, Yoshihide [1 ]
Higashi, Tetsuji [1 ]
Wakida, Shin-ichi [1 ]
机构
[1] Natl Inst AIST, HSS Res Ctr, Ikeda, Osaka 5638577, Japan
关键词
microchip capillary electrophoresis; poly(metheylmethacrylate) chip; dynamic coating; protein; EOF control;
D O I
10.1016/j.chroma.2006.07.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
New dynamic coating agents were investigated for the manipulation of electroosmotic flow (EOF) in poly(methylmethacrylate) (PMMA) microchips. Blocking proteins designed for enzyme-linked immunosorbent assay (ELISA) applications (e.g. Block Ace and UItraBlock), and egg-white lysozyme were proposed in this study. The EOF could be enhanced, suppressed or its direction could be reversed, depending on the buffer pH and the charge on the proteins. The coating procedure is simple, requiring only filling of the microchannels with a coating solution, followed by a rinse with a running buffer solution prior to analysis. One major advantage of this method is that it is not necessary to add the coating agent to the running buffer solution. Block Ace and UltraBlock coatings were stable for at least five runs in a given microchannel without the need to condition the coating between runs other than replenishing the buffer solution after each run, i.e. the RSD values of EOF (n = 5) were less than 4.3%, and there was no significant change in the EOF after 5 runs. The reproducibility of the coating procedures was found from the channel-to-channel RSD values of the EOF, and were less than 5.0% when using HEPES-Na buffer (pH 7.4) as the running buffer. Several examples of electrophoretic separations of amino acids and biogenic amines derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) are demonstrated in this paper. The dynamic coating method has the potential for a broad range of applications in microchip capillary electrophoresis (microchip CE) separations. (c) 2006 Elsevier B.V All rights reserved.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 42 条
  • [31] Microchip electrophoretic protein separation using electroosmotic flow induced by dynamic sodium dodecyl sulfate-coating of uncoated plastic chips
    Nagata, H
    Tabuchi, M
    Hirano, K
    Baba, Y
    ELECTROPHORESIS, 2005, 26 (11) : 2247 - 2253
  • [32] Sensitive and rapid determination of nitric oxide in human serum using microchip capillary electrophoresis with laser-induced fluorescence detection
    Yan Wang
    Ming Yin
    Microchimica Acta, 2009, 166 : 243 - 249
  • [33] Separation of peptides and proteins by capillary electrophoresis using acidic buffers containing tetraalkylammonium cations and cyclodextrins
    Quang, CY
    Malek, A
    Khaledi, MG
    ELECTROPHORESIS, 2003, 24 (05) : 824 - 828
  • [34] N-methyl-2-pyrrolidonium methyl sulfonate acidic ionic liquid as a new dynamic coating for separation of basic proteins by capillary electrophoresis
    Guo, Xiao-Feng
    Chen, Hui-Ying
    Zhou, Xiao-Hai
    Wang, Hong
    Zhang, Hua-Shan
    ELECTROPHORESIS, 2013, 34 (24) : 3287 - 3292
  • [35] CHARACTERIZATION OF SEVERAL MILK PROTEINS IN DOMESTIC BALKAN DONKEY BREED DURING LACTATION, USING LAB-ON-A-CHIP CAPILLARY ELECTROPHORESIS
    Gubic, Jasmina
    Tomic, Jelena
    Torbica, Aleksandra
    Ilicic, Mirela
    Tasic, Tatjana
    Saric, Ljubisa
    Popovic, Sanja
    CHEMICAL INDUSTRY & CHEMICAL ENGINEERING QUARTERLY, 2016, 22 (01) : 9 - 15
  • [36] High-sensitive analysis of heme proteins separated by capillary electrophoresis with on-line chemiluminescence detection using a luminol and hydrogen peroxide system
    Tsukagoshi, K
    Fujimura, S
    Nakajima, R
    ANALYTICAL SCIENCES, 1997, 13 (02) : 279 - 281
  • [37] High-Sensitive Analysis of Heme Proteins Separated by Capillary Electrophoresis with On-Line Chemiluminescence Detection Using a Luminol and Hydrogen Peroxide System
    Kazuhiko Tsukagoshi
    Shigehiro Fujimura
    Riichiro Nakajima
    Analytical Sciences, 1997, 13 : 279 - 281
  • [38] Highly reproducible capillary gel electrophoresis (CGE) of DNA fragments using uncoated columns.: Detection of genetically modified maize by PCR-CGE
    García-Cañas, V
    González, R
    Cifuentes, A
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (09): : 577 - 583
  • [39] Dynamic Coating Capillary Electrophoresis for Separation of Humic Acid Using Mixture Solution of Non-ionic Polymers both as Coating Agent and Separation Medium
    Toru Takahashi
    Jun Kawana
    Yuuki Tamura
    Hitoshi Hoshino
    Analytical Sciences, 2013, 29 : 1099 - 1102
  • [40] Dynamic Coating Capillary Electrophoresis for Separation of Humic Acid Using Mixture Solution of Non-ionic Polymers both as Coating Agent and Separation Medium
    Takahashi, Toru
    Kawana, Jun
    Tamura, Yuuki
    Hoshino, Hitoshi
    ANALYTICAL SCIENCES, 2013, 29 (11) : 1099 - 1102