Prosthesis-patient mismatch after transcatheter aortic valve implantation

被引:4
作者
Leone, Pier Pasquale [1 ]
Pagnesi, Matteo [2 ]
Regazzoli, Damiano [1 ]
Latib, Azeem [3 ]
机构
[1] Humanitas Clin & Res Ctr IRCCS, Cardio Ctr, UO Cardiol, Rozzano, MI, Italy
[2] IRCCS Osped San Raffaele, UO Cardiol Interventist, Milan, Italy
[3] Montefiore Med Ctr, Cardiol Dept, New York, NY USA
关键词
Aortic stenosis; Prosthesis-patient mismatch; Small annuli; Transcatheter aortic valve implantation; Valve-in-valve; LONG-TERM SURVIVAL; HIGH-RISK PATIENTS; CLINICAL IMPACT; BIOPROSTHETIC VALVE; EVOLUT PRO; REPLACEMENT; OUTCOMES; MORTALITY; STENOSIS; PREDICTORS;
D O I
10.1714/3487.34670
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Prosthesis-patient mismatch (PPM) is present when the actual area of an implanted prosthetic valve is too small compared to the size of the patient's body. Its main hemodynamic consequence is that of generating higher than expected gradients through prosthetic valves which are normally functioning. This review aims to update on the incidence of PPM after transcatheter aortic valve implantation (TAVI) and its long-term clinical impact through a review of the clinical studies available to date. Furthermore, this review will focus on some particular settings, such as TAVI procedures in small annuli or valve-in-valve, which have a higher risk of encountering this complication. Finally, we will focus on the strategies available to reduce the risk of PPM when planning a TAVI procedure.
引用
收藏
页码:26S / 34S
页数:9
相关论文
共 50 条
[41]   Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement It Is Neither Rare Nor Benign [J].
Pibarot, Philippe ;
Clavel, Marie-Annick .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) :2712-2716
[42]   Prosthesis-Patient Mismatch After Aortic Valve Replacement in the PARTNER 2 Trial and Registry [J].
Ternacle, Julien ;
Pibarot, Philippe ;
Herrmann, Howard C. ;
Kodali, Susheel ;
Leipsic, Jonathon ;
Blanke, Philipp ;
Jaber, Wael ;
Mack, Michael J. ;
Clavel, Marie-Annick ;
Salaun, Erwan ;
Guzzetti, Ezequiel ;
Annabi, Mohamed-Salah ;
Bernier, Mathieu ;
Beaudoin, Jonathan ;
Khalique, Omar K. ;
Weissman, Neil J. ;
Douglas, Pamela ;
Bax, Jeroen ;
Dahou, Abdellaziz ;
Xu, Ke ;
Alu, Maria ;
Rogers, Erin ;
Leon, Martin ;
Thourani, Vinod H. ;
Abbas, Amr E. ;
Hahn, Rebecca T. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (13) :1466-1477
[43]   Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement Of Asians and Non-Asians [J].
Wang, Jian'an ;
He, Yuxin .
JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (24) :2682-2684
[44]   Long-term outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement [J].
Compagnone, Miriam ;
Marchetti, Giulia ;
Taglieri, Nevio ;
Ghetti, Gabriele ;
Bruno, Antonio Giulio ;
Orzalkiewicz, Mateusz ;
Marrozzini, Cinzia ;
Reggiani, Maria-Letizia Bacchi ;
Palmerini, Tullio ;
Galie, Nazzareno ;
Saia, Francesco .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 318 :27-31
[45]   Impact of prosthesis-patient mismatch on early and late mortality after aortic valve replacement [J].
Koene, Bart M. ;
Hamad, Mohamed A. Soliman ;
Bouma, Wobbe ;
Mariani, Massimo A. ;
Peels, Kathinka C. ;
van Dantzig, Jan-Melle ;
van Straten, Albert H. .
JOURNAL OF CARDIOTHORACIC SURGERY, 2013, 8
[46]   Prosthesis-patient mismatch defined by cardiac computed tomography versus echocardiography after transcatheter aortic valve replacement [J].
Fukui, Miho ;
Garcia, Santiago ;
Lesser, John R. ;
Gossl, Mario ;
Tang, Liang ;
Caye, David ;
Newell, Marc ;
Hashimoto, Go ;
Lopes, Bernardo B. C. ;
Stanberry, Larissa, I ;
Enriquez-Sarano, Maurice ;
Pibarot, Philippe ;
Hahn, RebeccaT ;
Sorajja, Paul ;
Cavalcante, Joao L. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (05) :403-411
[47]   Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement in Asian Patients [J].
Chen, Ying-Hwa ;
Chang, Hsiao-Huang ;
Kuo, Chia-Cheng ;
Leu, Hsin-Bang ;
Lin, Su-Man .
ANNALS OF THORACIC SURGERY, 2022, 114 (05) :1612-1619
[48]   Prosthesis-patient mismatch after transcatheter aortic valve implantation: impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography [J].
da Silva, Cristina ;
Sahlen, Anders ;
Winter, Reidar ;
Back, Magnus ;
Ruck, Andreas ;
Settergren, Magnus ;
Manouras, Aristomenis ;
Shahgaldi, Kambiz .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (08) :1549-1557
[49]   Five-Year Outcomes of Measured and Predicted Prosthesis-Patient Mismatch following Transcatheter Aortic Valve Implantation [J].
Al-Azizi, Karim ;
Moubarak, Ghadi ;
Mohiuddin, Asim ;
Szerlip, Molly ;
Potluri, Srinivasa ;
Harrington, Katherine ;
Schaffer, Justin ;
Brinkman, William ;
Alsaid, Amro ;
Wang, Zuyue ;
Ladner, Jonathan ;
Gunukula, Rahul ;
Parro, Colleen ;
Ma, Tsung-Wei ;
Stoler, Robert ;
Chugh, Yashasvi ;
Banerjee, Subhash ;
Mixon, Timothy ;
Widmer, Robert J. ;
Caldera, Angel ;
Contreras, Jose Condado ;
Krueger, Anita ;
Gray, William ;
DiMaio, J. Michael ;
Mack, Michael J. .
AMERICAN JOURNAL OF CARDIOLOGY, 2024, 231 :11-19
[50]   Prosthesis-patient mismatch is an independent predictor of congestive heart failure after transcatheter aortic valve replacement [J].
Theron, Alexis ;
Lavagna, Flora ;
Gaubert, Guillaume ;
Resseguier, Noemie ;
Porto, Alizee ;
Ferrara, Jerome ;
Jaussaud, Nicolas ;
Morera, Pierre ;
Cuisset, Thomas ;
Deharo, Pierre ;
Collart, Frederic .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2021, 114 (6-7) :504-514