摘要
Prosthesis-patient mismatch (PPM) is present when the actual area of an implanted prosthetic valve is too small compared to the size of the patient's body. Its main hemodynamic consequence is that of generating higher than expected gradients through prosthetic valves which are normally functioning. This review aims to update on the incidence of PPM after transcatheter aortic valve implantation (TAVI) and its long-term clinical impact through a review of the clinical studies available to date. Furthermore, this review will focus on some particular settings, such as TAVI procedures in small annuli or valve-in-valve, which have a higher risk of encountering this complication. Finally, we will focus on the strategies available to reduce the risk of PPM when planning a TAVI procedure.
引用
收藏
页码:26S / 34S
页数:9
相关论文
共 50 条
[21]   Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement [J].
Freeman, Melanie ;
Webb, John G. ;
Willson, Alexander B. ;
Wheeler, Miriam ;
Blanke, Philipp ;
Moss, Robert R. ;
Thompson, Christopher R. ;
Munt, Brad ;
Norgaard, Bjarne L. ;
Yang, Tae-Hyun ;
Min, James K. ;
Poulsen, Steen ;
Hansson, Nicolaj C. ;
Binder, Ronald K. ;
Toggweiler, Stefan ;
Hague, Cameron ;
Wood, David A. ;
Pibarot, Philippe ;
Leipsic, Jonathon .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (04) :248-255
[22]   Impact of prosthesis-iteration evolution and sizing practice on the incidence of prosthesis-patient mismatch after transcatheter aortic valve replacement [J].
Abdelghani, Mohammad ;
Allali, Abdelhakim ;
Kaur, Jatinderjit ;
Hemetsberger, Rayyan ;
Mehilli, Julinda ;
Neumann, Franz-Josef ;
Frerker, Christian ;
Kurz, Thomas ;
El-Mawardy, Mohamed ;
Richardt, Gert ;
Abdel-Wahab, Mohamed .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (05) :971-979
[23]   Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement Has It Become Obsolete? [J].
Ternacle, Julien ;
Abbas, Amr E. ;
Pibarot, Philippe .
JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (09) :977-980
[24]   Prosthesis-Patient Mismatch After "High-Risk" Aortic Valve Replacement [J].
Popma, Jeffrey J. ;
Khabbaz, Kamal .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (13) :1335-1338
[25]   Impact of Measured and Predicted Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement [J].
Guthoff, Henning ;
Abdel-Wahab, Mohamed ;
Kim, Won-Keun ;
Witberg, Guy ;
Wienemann, Hendrik ;
Thurow, Maria ;
Shamekhi, Jasmin ;
Eckel, Clemens ;
von der Heide, Ina ;
Veulemans, Verena ;
Landt, Martin ;
Barbanti, Marco ;
Finkelstein, Ariel ;
Schewel, Jury ;
Van Mieghem, Nicolas ;
Adrichem, Rik ;
Toggweiler, Stefan ;
Rheude, Tobias ;
Nombela-Franco, Luis ;
Amat-Santos, Ignacio J. ;
Ruile, Philipp ;
Estevez-Loureiro, Rodrigo ;
Bunc, Matjaz ;
Branca, Luca ;
De Backer, Ole ;
Tarantini, Giuseppe ;
Mylotte, Darren ;
Arzamendi, Dabit ;
Pauly, Markus ;
Bleiziffer, Sabine ;
Renker, Matthias ;
Al-Kassou, Baravan ;
Mollmann, Helge ;
Ludwig, Sebastian ;
Zeus, Tobias ;
Tamburino, Corrado ;
Schmidt, Tobias ;
Rueck, Andreas ;
von Stein, Philipp ;
Thiele, Holger ;
Abdelhafez, Ahmed ;
Adam, Matti ;
Baldus, Stephan ;
Rudolph, Tanja ;
Mauri, Victor .
JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (22) :2626-2635
[26]   Impact of Prosthesis-Patient Mismatch on 1-Year Outcomes after Transcatheter Aortic Valve Implantation: Meta-analysis of 71,106 Patients [J].
Barros Oliveira Sa, Michel Pompeu ;
Pereira Cavalcanti, Luiz Rafael ;
Santos Sarargiotto, Felipe Augusto ;
Perazzo, Alvaro Monteiro ;
Rayon, Sergio da Costa ;
Silva Diniz, Roberto Gouveia ;
Correia Araujo Sa, Frederico Browne ;
Menezes, Alexandre Motta ;
Lima, Ricardo Carvalho .
BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2019, 34 (03) :318-326
[27]   Prosthesis-Patient Mismatch in the Transcatheter Aortic Valve Replacement Era [J].
Tuzcu, E. Murat ;
Oezkan, Alper ;
Kapadia, Samir R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) :1919-1922
[28]   Prosthesis-Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve Replacement From the STS/ACC TVT Registry [J].
Herrmann, Howard C. ;
Daneshvar, Samuel A. ;
Fonarow, Gregg C. ;
Stebbins, Amanda ;
Vemulapalli, Sreekanth ;
Desai, Nimesh D. ;
Malenka, David J. ;
Thourani, Vinod H. ;
Rymer, Jennifer ;
Kosinski, Andrzej S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) :2701-2711
[29]   Prosthesis-Patient Mismatch in Patients With Bicuspid Aortic Valve [J].
Messika-Zeitoun, David ;
Burwash, Ian G. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2025, 18 (04) :503-505
[30]   Valve-in-Valve Transcatheter Aortic Valve Implantation: The New Playground for Prosthesis-Patient Mismatch [J].
Faerber, Gloria ;
Schleger, Simone ;
Diab, Mahmoud ;
Breuer, Martin ;
Figulla, Hans R. ;
Eichinger, Walter B. ;
Doenst, Torsten .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2014, 27 (03) :287-292