A simple and effective method for addition silicone impression disinfection

被引:26
作者
Azevedo, Maria Joao [1 ]
Correia, Ines [1 ]
Portela, Ana [1 ]
Sampaio-Maia, Benedita [1 ,2 ,3 ]
机构
[1] Univ Porto, Fac Dent Med, Rua Dr Manuel Pereira da Silva, P-4200393 Porto, Portugal
[2] Univ Porto, Natl Inst Biomed Engn, Porto, Portugal
[3] Univ Porto, Inst Res & Innovat Hlth, Porto, Portugal
关键词
Silicone elastomers; Disinfection; Sodium hypochlorite; Hydrogen peroxide; DENTAL IMPRESSIONS; MICROWAVE IRRADIATION; DIMENSIONAL STABILITY; IMMERSION; SURFACE; ACCURACY;
D O I
10.4047/jap.2019.11.3.155
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. Although dental impression disinfection is determinant to reduce the cross-infection risk, some studies have shown that, in real practice, the disinfection procedures vary considerably. Thus, the aim of this study was to evaluate the antimicrobial effectiveness and the impact on the dimensional stability of addition silicone' impressions of water wash and the most clinically used disinfection solutions: 3% hydrogen peroxide, commercial disinfectant MD520 (Durr) and 1% and 5.25% sodium hypochlorite. MATERIALS AND METHODS. For this investigation, dental impressions were taken on 16 volunteer dental students. The antimicrobial effectiveness of each procedure was evaluated by pour plate method. The dimensional stability was evaluated using a standardized stainless-steel model, according to ANSI/ADA n degrees 19 specification. RESULTS. The study results showed that water wash does not alter the dimensional stability of addition silicone impressions but doesn't reduce the microbial load of the material (P>.05). On the other hand, addition silicone disinfection by immersion with 3% hydrogen peroxide, MD520 (Durr), or sodium hypochlorite at 1% and 5.25% does not alter the dimensional stability significantly but reduces > 99.9% of the microbial load of the impressions (P<.001). CONCLUSION. Addition silicone impressions should always be disinfected after water wash in order to reduce effectively the cross-infection risk. All disinfectants tested showed high antimicrobial efficiency without significant changes in three-dimensional shape of impressions. Hydrogen peroxide and sodium hypochlorite are of particular importance because are easily accessible in dental setting. The less explored hydrogen peroxide could be a valuable alternative for silicone impressions disinfection.
引用
收藏
页码:155 / 161
页数:7
相关论文
共 50 条
  • [31] Disinfection of contact lenses without tap water rinsing: Is it effective?
    David V Seal
    Alan Dalton
    Derek Doris
    Eye, 1999, 13 : 226 - 230
  • [32] Disinfection of contact lenses without tap water rinsing: is it effective?
    Seal, DV
    Dalton, A
    Doris, D
    EYE, 1999, 13 (2) : 226 - 230
  • [33] Efficacy evaluation of an air-assisted electrostatic disinfection device for the effective disinfection and sanitization against the spread of pathogenic infections
    Chauhan, Aarti
    Patel, Manoj Kumar
    Chaudhary, Shilpa
    Nayak, Manoj Kumar
    Saini, Surender Singh
    Pullammanappallil, Pratap
    Manivannan, Nadarajah
    Mitchell, Geoffrey Robert
    Balachandran, Wamadeva
    JOURNAL OF ELECTROSTATICS, 2023, 123
  • [34] Developing a Simple Strategy for Roadside Spring Water Disinfection in Central Appalachia
    Patton, Hannah
    Krometis, Leigh-Anne
    Faulkner, Ben B.
    Cohen, Alasdair
    Ling, Erin
    Sarver, Emily
    JOURNAL OF CONTEMPORARY WATER RESEARCH & EDUCATION, 2023, 178 (01) : 1 - 16
  • [35] The Hydraulic Squeegee: A Novel and Simple Method for Removing Silicone Oil From an Intraocular Lens
    Mehta, Mitul C.
    Foster, Robert E.
    Peterson, Michael R.
    Miller, Daniel M.
    Riemann, Christopher D.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (10): : 1536 - 1537
  • [36] EFFECT OF DISINFECTION ON IRREVERSIBLE HYDROCOLLOID AND ALTERNATIVE IMPRESSION MATERIALS AND THE RESULTANT GYPSUM CASTS
    Suprono, Montry S.
    Kattadiyil, Mathew T.
    Goodacre, Charles J.
    Winer, Myron S.
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 108 (04) : 250 - 258
  • [37] Effective of different industrial disinfection in subzero cold-chain environment
    Ren, Zhe
    Han, Jie
    Zhang, Xue
    Yan, Zheng
    Wei, Qiuhua
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [38] Disinfection Procedures and Their Effect on the Microorganism Colonization of Dental Impression Materials: A Systematic Review and Meta-Analysis of In Vitro Studies
    Hardan, Louis
    Bourgi, Rim
    Cuevas-Suarez, Carlos Enrique
    Lukomska-Szymanska, Monika
    Cornejo-Rios, Elizabeth
    Tosco, Vincenzo
    Monterubbianesi, Riccardo
    Mancino, Sara
    Eid, Ammar
    Mancino, Davide
    Kharouf, Naji
    Haikel, Youssef
    BIOENGINEERING-BASEL, 2022, 9 (03):
  • [39] Influence of temperature on the dimensional stability of an addition silicone
    Almeida, Carlos F.
    Dantas, Filipe
    Portela, Ana
    Vasconcelos, Mario
    Campos, J. C. Reis
    BIODENTAL ENGINEERING V, 2019, : 11 - 13
  • [40] Influence of temperature on the accuracy of an autoclaved addition silicone
    Pimentel, Luis
    Portugal, Jaime
    Vasconcelos, Mario
    Rocha, Paulo Almeida
    Sampaio-Fernandes, Joao Carlos
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2014, 55 (01): : 43 - 48