Dual-energy X-ray absorptiometry of the pig: Protocol development and evaluation

被引:10
|
作者
Nielsen, DH
McEvoy, FJ
Poulsen, HL
Madsen, MT
Buelund, LE
Svalastoga, E
机构
[1] Royal Vet & Agr Univ, Dept Clin Studies, Radiol Sect, DK-18770 Frederiksberg C, Denmark
[2] Natl Comm Pig Prod, Dept Nutr & Reprod, DK-1609 Copenhagen, Denmark
关键词
bone mineralisation; pig; precision; accuracy;
D O I
10.1016/j.meatsci.2004.03.002
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
As part of a prospective study in bone mineralisation in adult pigs it was necessary to establish guidelines and to define sites for bone mineral measurements. Particular requirements were that, the protocol should be suitable for a mass screening programme in both postmortem specimens and in live animals, and should deliver results of known reliability. Estimates of bone mineral content (BMC) and bone mineral density (BMD) in areas within the 4th metacarpal bone yielded coefficients of variation (CV) in the order of 7% for both regions and estimates in regions which included the entire metacarpal-phalangeal area yielded CV values in the order of 0.7% and 0.6% for BMC and BMD, respectively. A region of interest taken from the coccygeal vertebrae yielded coefficient of variation values of 3% and 2% for BMC and BMD, respectively. Accuracy of dual-energy X-ray absorptiometry (DXA) was estimated using a standard curve derived from BMC determined by ashing. There was a high correlation between mineral content determined by DXA and by ashing (R-2 = 0.99, p < 0.0001). The results suggest that the regions used in this study are suitable for use in large, mass screening, prospective studies. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:235 / 241
页数:7
相关论文
共 50 条
  • [11] Dual-energy x-ray absorptiometry in osteopetrosis
    Adler, IN
    Stine, KC
    Kurtzburg, J
    Kinder, DL
    Cox, KS
    Lensing, SY
    Seibert, JJ
    SOUTHERN MEDICAL JOURNAL, 2000, 93 (05) : 501 - 503
  • [12] Calibration of dual-energy x-ray absorptiometry estimating pig body composition
    Kipper, M.
    Marcoux, M.
    Andretta, I
    Pomar, C.
    ENERGY AND PROTEIN METABOLISM AND NUTRITION, 2019, 138 : 427 - 429
  • [13] Dual-Energy X-Ray Absorptiometry in the Evaluation of Abdominal Aortic Calcifications
    Bazzocchi, Alberto
    Ciccarese, Federica
    Diano, Danila
    Spinnato, Paolo
    Albisinni, Ugo
    Rossi, Cristina
    Guglielmi, Giuseppe
    JOURNAL OF CLINICAL DENSITOMETRY, 2012, 15 (02) : 198 - 204
  • [14] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18
  • [15] X-Ray Filter Design and Its Evaluation in Dual-Energy X-Ray Absorptiometry (DXA)
    Kim, Kwang Hyun
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) : 2155 - 2158
  • [16] SIMULATION STUDIES OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    SORENSON, JA
    DUKE, PR
    SMITH, SW
    MEDICAL PHYSICS, 1989, 16 (01) : 75 - 80
  • [17] Dual-energy X-ray absorptiometry in early life
    Lapillonne, A
    Braillon, PM
    Delmas, PD
    Salle, BL
    HORMONE RESEARCH, 1997, 48 : 43 - 49
  • [18] Dual-energy X-ray absorptiometry scan: Guidelines
    Haymann, Jean-Philippe
    PROGRES EN UROLOGIE, 2010, 20 (04): : F119 - F122
  • [19] DUAL-ENERGY X-RAY ABSORPTIOMETRY IN NEUROMUSCULAR DISEASES
    KANDA, F
    FUJII, Y
    TAKAHASHI, K
    FUJITA, T
    MUSCLE & NERVE, 1994, 17 (04) : 431 - 435
  • [20] DUAL-ENERGY X-RAY ABSORPTIOMETRY - INTEREST IN ORTHOPEDICS
    MAUGARS, Y
    BERTHELOT, JM
    DELECRIN, J
    TRECANT, M
    PASSUTI, N
    DACULSI, G
    PROST, A
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1995, 81 (04): : 326 - 332