Coupling and decoupling theory and its application to the MRI phased array

被引:161
作者
Lee, RF [1 ]
Giaquinto, RO [1 ]
Hardy, CJ [1 ]
机构
[1] GE Co, Ctr Corp Res & Dev, Schenectady, NY 12309 USA
关键词
parallel spatial encoding; MRI phased array; coupling; decoupling; decoupling interface;
D O I
10.1002/mrm.10186
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In classical MRI phased-array design, optimal coil overlapping is used to minimize coupling between nearest-neighbor coils, and low input impedance preamplifiers are used to isolate the relatively weak coupling between non-nearest neighbors. However, to make the complex sensitivities of phased-array coils sufficiently distinct in parallel spatially-en coded MRI, it is desirable to have no overlapping between coils. Also, if phased arrays are used as transmit coils in MRI, one can no longer rely on the low input impedance of the preamplifiers for decoupling. Here a coupling and decoupling theory is introduced to provide a better understanding of the relations between coupled and uncoupled signals in the MRI phased array, and to offer a new method for decoupling phased-array coils without overlapping the nearest coil pairs. The new decoupling method is based on the assumption that any n-element phased array can be decoupled by a 2n-port interface system between phased array and preamplifiers. The detailed analysis and the experimental results show that a four-port interface can be used to decouple a two-element phased array. Furthermore, the four-port interfaces can serve as building blocks to construct a 2n-port decoupling interface. This new method allows one to place the coil elements anywhere that could optimize parallel spatial encoding without concern for coupling between the coils. The method can also be used for phased-array transmit coils. (C) Wiley-Liss, Inc.
引用
收藏
页码:203 / 213
页数:11
相关论文
共 29 条
[1]  
Chen CN, 1989, BIOMEDICAL MAGNETIC
[2]   Maximizing signal-to-noise ratio in the presence of coil coupling [J].
Duensing, GR ;
Brooker, HR ;
Fitzsimmons, JR .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1996, 111 (03) :230-235
[3]  
GRISWOOD MA, 2001, ISMRM WORKSH MRI HAR, P13
[4]   PARALLEL IMAGE ACQUISITION FROM NONINTERACTING LOCAL COILS [J].
HYDE, JS ;
JESMANOWICZ, A ;
FRONCISZ, W ;
KNEELAND, JB ;
GRIST, TM ;
CAMPAGNA, NF .
JOURNAL OF MAGNETIC RESONANCE, 1986, 70 (03) :512-517
[5]  
Jevtic J., 2001, P 9 ANN M ISMRM GLAS, P17
[6]  
Lee RF, 2000, MAGNET RESON MED, V43, P269, DOI 10.1002/(SICI)1522-2594(200002)43:2<269::AID-MRM14>3.0.CO
[7]  
2-J
[8]   Planar strip array (PSA) for MRI [J].
Lee, RF ;
Westgate, CR ;
Weiss, RG ;
Newman, DC ;
Bottomley, PA .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :673-683
[9]  
Lee RF, 2000, MAGNET RESON MED, V43, P716, DOI 10.1002/(SICI)1522-2594(200005)43:5<716::AID-MRM14>3.0.CO
[10]  
2-K