Feasibility study of a LED light irradiation device for the treatment of chronic neck with shoulder muscle pain/stiffness

被引:3
|
作者
Odagiri, Keiichi [1 ]
Yamauchi, Katsuya [2 ]
Toda, Masahiro [2 ]
Uchida, Ayako [1 ]
Tsubota, Hiromi [1 ,4 ]
Zenba, Kazuyoshi [3 ]
Okawai, Hiroaki
Eda, Hideo [5 ]
Mizuno, Seiichiro [5 ]
Yokota, Hiroaki [5 ]
机构
[1] Hamamatsu Univ Hosp, Clin Res Ctr, Hamamatsu, Japan
[2] Hamamatsu Univ Sch Med, Dept Rehabil Med, Hamamatsu, Japan
[3] Isehara Clin Trial Ctr, Zenba Acupuncture & Moxibust Clin, Isehara, Japan
[4] Kenkou Data House Inc, Sendai, Japan
[5] Grad Sch Creat New Photon Ind, Hamamatsu, Japan
来源
PLOS ONE | 2022年 / 17卷 / 10期
关键词
LEVEL LASER THERAPY; GENERAL-POPULATION; PAIN; MANAGEMENT; EXERCISE;
D O I
10.1371/journal.pone.0276320
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Neck with shoulder muscle stiffness/pain is a common disorder. Commonly used physical therapy, pharmacotherapy, acupuncture, and moxibustion only temporarily alleviate the disorder in most cases, thus the disorder often recurs. Low power laser therapy is often used for neck and shoulder stiffness/pain and has been effective in clinical trials. In this study, we evaluated the safety and effectiveness of a newly developed self-care device for disorders including neck with shoulder muscle stiffness/pain. The device incorporates light-emitting diodes (LEDs), which are safer than lasers, as its light source. Ten adults with neck with shoulder muscle stiffness/pain were subject to LED irradiation (wavelength 780 nm +/- 15 nm, output 750 mW, power density 3.8 W/cm(2), energy density 5.7x10(2) J/cm(2)) for 3 minutes on the affected shoulder at a standard acupuncture point (GB21, Jianjing). Immediately after irradiation, the subjective symptoms of the neck with shoulder muscle stiffness and pain evaluated by a visual analog scale were improved from 58.3 mm +/- 18.7 mm to 45.5 mm +/- 21.5 mm and from 45.8 mm +/- 23.3 mm to 39.4 mm +/- 21.8 mm, respectively. The symptoms further improved after 15 minutes of irradiation. The skin temperature at the irradiated point increased from 34.3 degrees C +/- 1.1 degrees C to 41.0 degrees C +/- 0.7 degrees C. The increase in skin temperature was observed within approximately 5 cm of the irradiated area. There was no effect on the heart rate variability, a measure of the autonomic nervous system; however, the baroreflex sensitivity was slightly increased. No irradiation-related adverse skin events were observed. Our LED irradiation device was found to be safe, and it improved the subjective symptoms of muscle stiff neck with shoulders.
引用
收藏
页数:11
相关论文
共 43 条
  • [41] Effect of Godelieve Denys-Struyf (GDS) muscle and articulation chain treatment on clinical variables of patients with chronic low back pain and lumbar disc degeneration: a pilot feasibility randomized controlled trial
    Lombardo, Sidsel
    Hilde, Gunvor
    Smastuen, Milada Cvancarova
    Grotle, Margreth
    PILOT AND FEASIBILITY STUDIES, 2023, 9 (01)
  • [42] Acupuncture with non-steroidal anti-inflammatory drugs (NSAIDs) versus acupuncture or NSAIDs alone for the treatment of chronic neck pain: an assessor-blinded randomised controlled pilot study
    Cho, Jae-Heung
    Nam, Dong-Hyun
    Kim, Ki-Tack
    Lee, Jun-Hwan
    ACUPUNCTURE IN MEDICINE, 2014, 32 (01) : 17 - 23
  • [43] Effectiveness and safety of polydioxanone thread embedding acupuncture compared to physical therapy in the treatment of patients with non-specific chronic neck pain Study protocol for an assessor-blinded, randomized, controlled, clinical trial
    Kim, Jae Ik
    Kim, Young Il
    Kim, Eunseok
    Jeon, Ju Hyun
    Kim, Jin Youp
    Kwon, Ojin
    Jung, So-Young
    Han, Chang-Hyun
    MEDICINE, 2019, 98 (32)