Integrated Circuits for Volumetric Ultrasound Imaging With 2-D CMUT Arrays

被引:83
|
作者
Bhuyan, Anshuman [1 ]
Choe, Jung Woo [1 ]
Lee, Byung Chul [1 ]
Wygant, Ira O. [2 ]
Nikoozadeh, Amin [1 ]
Oralkan, Omer [3 ]
Khuri-Yakub, Butrus T. [1 ]
机构
[1] Stanford Univ, Edward L Ginzton Lab, Stanford, CA 94305 USA
[2] Texas Instruments Inc, Sunnyvale, CA 94089 USA
[3] N Carolina State Univ, Dept Elect Engn, Raleigh, NC 27606 USA
关键词
2D array; capacitive micromachined ultrasonic transducer (CMUT); flip-chip bonding; integrated circuits; phased array imaging; ultrasound; volumetric imaging; TRANSDUCERS; VOLTAGE; FETUS;
D O I
10.1109/TBCAS.2014.2298197
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Real-time volumetric ultrasound imaging systems require transmit and receive circuitry to generate ultrasound beams and process received echo signals. The complexity of building such a system is high due to requirement of the front-end electronics needing to be very close to the transducer. A large number of elements also need to be interfaced to the back-end system and image processing of a large dataset could affect the imaging volume rate. In this work, we present a 3-D imaging system using capacitive micromachined ultrasonic transducer (CMUT) technology that addresses many of the challenges in building such a system. We demonstrate two approaches in integrating the transducer and the front-end electronics. The transducer is a 5-MHz CMUT array with an 8 mm x 8 mm aperture size. The aperture consists of 1024 elements (32 x 32) with an element pitch of 250 mu m. An integrated circuit (IC) consists of a transmit beamformer and receive circuitry to improve the noise performance of the overall system. The assembly was interfaced with an FPGA and a back-end system (comprising of a data acquisition system and PC). The FPGA provided the digital I/O signals for the IC and the back-end system was used to process the received RF echo data (from the IC) and reconstruct the volume image using a phased array imaging approach. Imaging experiments were performed using wire and spring targets, a ventricle model and a human prostrate. Real-time volumetric images were captured at 5 volumes per second and are presented in this paper.
引用
收藏
页码:796 / 804
页数:9
相关论文
共 50 条
  • [41] 2-D Ultrasound Sparse Arrays Multidepth Radiation Optimization Using Simulated Annealing and Spiral-Array Inspired Energy Functions
    Roux, Emmanuel
    Ramalli, Alessandro
    Tortoli, Piero
    Cachard, Christian
    Robini, Marc C.
    Liebgott, Herve
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (12) : 2138 - 2149
  • [42] 2-D AND 3-D ULTRASOUND FOR TUMOR VOLUME ANALYSIS: A PROSPECTIVE STUDY
    Gonzalez, Segundo J.
    Mooney, Blaise
    Lin, Hui-Yi
    Zhao, Xiuhua
    Kiluk, John V.
    Khakpour, Nazanin
    Laronga, Christine
    Lee, M. Catherine
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (04) : 775 - 781
  • [43] Strain estimation in abdominal aortic aneurysms from 2-D ultrasound
    Brekken, R
    Bang, J
    Odegard, A
    Aasland, J
    Hernes, TAN
    Myhre, HO
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (01) : 33 - 42
  • [44] A novel approach to the 2-D blind deconvolution problem in medical ultrasound
    Michailovich, OV
    Adam, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (01) : 86 - 104
  • [45] New technology: 2-D cyclic variation of integrated backscatter image
    Li, X
    Bai, J
    Ding, CX
    Hu, GS
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2529 - 2531
  • [46] A New Parameter to Evaluate Fetal Sylvian Fissure by Transabdominal 2-D Ultrasound
    Zeng, Qing
    Wen, Huaxuan
    Liao, Yimei
    Luo, Dandan
    Qin, Yue
    Liang, Meiling
    Li, Shengli
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (09) : 2054 - 2059
  • [47] EVALUATION OF INDIRECT METHODS FOR MOTION COMPENSATION IN 2-D FOCAL LIVER LESION CONTRAST-ENHANCED ULTRASOUND (CEUS) IMAGING
    Bakas, Spyridon
    Doulgerakis-Kontoudis, Matthaios
    Hunter, Gordon J. A.
    Sidhu, Paul S.
    Makris, Dimitrios
    Chatzimichail, Katerina
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (06) : 1380 - 1396
  • [48] Volumetric imaging through a doubly-curved surface using a 2D phased array
    McKee, Jessica G.
    Bevan, Rhodri L. T.
    Wilcox, Paul D.
    Malkin, Robert E.
    NDT & E INTERNATIONAL, 2020, 113
  • [49] Coherent Bistatic 3-D Ultrasound Imaging Using Two Sparse Matrix Arrays
    De Hoop, Hein
    Vermeulen, Marieke
    Schwab, Hans-Martin
    Lopata, Richard G. P.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (03) : 182 - 196
  • [50] Bladder volume determination: Portable 3-D versus stationary 2-D ultrasound device
    Schnider, P
    Birner, P
    Gendo, A
    Ratheiser, K
    Auff, E
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2000, 81 (01): : 18 - 21