A system for quality assurance in radiosurgery

被引:3
作者
Mack, A [1 ]
Scheib, SG [1 ]
Rieker, M [1 ]
Weltz, D [1 ]
Mack, G [1 ]
Czempiel, H [1 ]
Kreiner, HJ [1 ]
Boettcher, HD [1 ]
Seifert, V [1 ]
机构
[1] Gamma Knife Zentrum, DE-60528 Frankfurt, Germany
来源
RADIOSUGERY, VOL 5 | 2004年 / 5卷
关键词
D O I
10.1159/000078123
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A quality assurance system has been developed for stereotactic radiosurgery and radiotherapy, to fulfill three goals: first to evaluate the geometrical error within imaging, second to simulate the complete chain of a treatment beginning with the imaging and ending with the application of dose, and third to verify calculated dose distributions in three dimensions with high spatial resolution and accuracy. A water-filled cylindrical imaging phantom has been manufactured in which equally spaced rods are placed. It can be mounted to a stereotactic frame in different orientations to be imaged using CT and MRI. The distances of the rod positions are analyzed and a reference grid can be positioned to calculate displacement vectors according to which e.g. the head coil can be adjusted. The spectral emission of the light and the filters together with the efficiency of the red CCD channel were matched and balanced with the absorption spectra of the radiochromic film used with the adapted drum scanner. Standardized software has been designed for evaluating the film data, for calibration, for correction of temperature and darkening and for test routines. A spherical phantom with shells and inserts of different tissue equivalent materials has been developed to simulate complex treatment situations within the human skull. Copyright (C) 2004 S. Karger AG, Basel.
引用
收藏
页码:236 / 246
页数:11
相关论文
共 50 条
  • [21] Quality assurance in stereotactic radiosurgery and fractionated stereotactic radiotherapy
    Solberg, T.
    Shepard, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2513 - 2514
  • [22] Evaluation of Delivery Quality Assurance of Cyberknife Stereotactic Radiosurgery
    Li, J.
    Zhang, X.
    Zhuang, H.
    Yang, R.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [23] Development and evaluation of quality assurance phantom for stereotactic radiosurgery
    Park, Soah
    Yoon, Jai-Woong
    Kim, Me young
    Cheong, Kwang-Ho
    Kang, Sei-Kwon
    Kim, Kyoung Ju
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 84 (06) : 488 - 495
  • [24] QUALITY ASSURANCE FOR GAMMA-KNIFE STEREOTAXIC RADIOSURGERY
    MAITZ, AH
    WU, A
    LUNSFORD, LD
    FLICKINGER, JC
    KONDZIOLKA, D
    BLOOMER, WD
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (05): : 1465 - 1471
  • [25] Application of routine quality assurance measures in stereotactic radiosurgery
    Hsu, F
    Mulroy, L
    Robar, J
    Rheaume, D
    Fleetwood, I
    Yewondwossen, M
    Wilke, D
    Schella, J
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S62 - S62
  • [26] Quality assurance of an image guided intracranial stereotactic positioning system for radiosurgery treatment with helical tomotherapy
    Emilie T. Soisson
    Nick Hardcastle
    Wolfgang A. Tomé
    Journal of Neuro-Oncology, 2010, 98 : 277 - 285
  • [27] Quality assurance of an image guided intracranial stereotactic positioning system for radiosurgery treatment with helical tomotherapy
    Soisson, Emilie T.
    Hardcastle, Nick
    Tome, Wolfgang A.
    JOURNAL OF NEURO-ONCOLOGY, 2010, 98 (02) : 277 - 285
  • [28] Image guidance quality assurance of a G4 CyberKnife robotic stereotactic radiosurgery system
    Pantelis, E.
    Petrokokkinos, L.
    Antypas, C.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [29] Automated stereotactic radiosurgery quality assurance using a portal imager
    Mamalui-Hunter, M.
    Drzymala, R.
    Willcut, V.
    Santanam, L.
    Low, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2642 - 2642
  • [30] Challenges in Quality Assurance for Volumetric Radiosurgery of Multiple Brain Metastases
    Karan, T.
    Duzenli, C. R.
    Bergman, A.
    Vollans, E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E697 - E697