A system for quality assurance in radiosurgery

被引:3
作者
Mack, A [1 ]
Scheib, SG [1 ]
Rieker, M [1 ]
Weltz, D [1 ]
Mack, G [1 ]
Czempiel, H [1 ]
Kreiner, HJ [1 ]
Boettcher, HD [1 ]
Seifert, V [1 ]
机构
[1] Gamma Knife Zentrum, DE-60528 Frankfurt, Germany
来源
RADIOSUGERY, VOL 5 | 2004年 / 5卷
关键词
D O I
10.1159/000078123
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A quality assurance system has been developed for stereotactic radiosurgery and radiotherapy, to fulfill three goals: first to evaluate the geometrical error within imaging, second to simulate the complete chain of a treatment beginning with the imaging and ending with the application of dose, and third to verify calculated dose distributions in three dimensions with high spatial resolution and accuracy. A water-filled cylindrical imaging phantom has been manufactured in which equally spaced rods are placed. It can be mounted to a stereotactic frame in different orientations to be imaged using CT and MRI. The distances of the rod positions are analyzed and a reference grid can be positioned to calculate displacement vectors according to which e.g. the head coil can be adjusted. The spectral emission of the light and the filters together with the efficiency of the red CCD channel were matched and balanced with the absorption spectra of the radiochromic film used with the adapted drum scanner. Standardized software has been designed for evaluating the film data, for calibration, for correction of temperature and darkening and for test routines. A spherical phantom with shells and inserts of different tissue equivalent materials has been developed to simulate complex treatment situations within the human skull. Copyright (C) 2004 S. Karger AG, Basel.
引用
收藏
页码:236 / 246
页数:11
相关论文
共 50 条
  • [1] Quality Assurance Results for a Commercial Radiosurgery System: A Communication
    Ruschin, Mark
    Lightstone, Alexander
    Beachey, David
    Wronski, Matt
    Babic, Steven
    Yeboah, Collins
    Lee, Young
    Soliman, Hany
    Sahgal, Arjun
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (05) : 601 - 605
  • [2] A Novel Iris Quality Assurance Phantom for the CyberKnife Radiosurgery System
    Descovich, M.
    Pinnaduwage, D.
    Sudhyadhom, A.
    Nelson, B.
    MEDICAL PHYSICS, 2015, 42 (06) : 3640 - 3640
  • [3] Quality assurance in stereotactic radiosurgery (QUASIR)
    Mack, A
    Scheib, S
    Weltz, D
    Czempiel, H
    Kreiner, HJ
    Mack, G
    MEDICAL PHYSICS, 2003, 30 (06) : 1522 - 1522
  • [4] RADIOSURGERY QUALITY ASSURANCE WITH EPID IMAGES
    Cardoso, I.
    Cardoso, I.
    Marcelino, C.
    Pontes, M.
    Coutinho, A.
    Lopes, S.
    Barreiros, M.
    Santos, V.
    Moreno, L.
    Carvoeiras, P.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S486 - S486
  • [5] Quality Assurance in Stereotactic Radiosurgery (QUASIR)
    Mack, A
    Scheib, S
    Weltz, D
    Czempiel, H
    Kreiner, HJ
    Mack, G
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S50 - S50
  • [6] Point dose verification in delivery quality assurance for gyroscopic radiosurgery system
    Yedekci, Yagiz
    Kivanc, Huseyin
    Biltekin, Fatih
    Yildiz, Demet
    Yazici, Gozde
    Ozyigit, Gokhan
    RADIATION PHYSICS AND CHEMISTRY, 2025, 234
  • [7] Quality Assurance for Imaging Guided Stereotactic RadioSurgery with Novalis Tx™ System
    Chang, Z.
    Wang, Z.
    Wu, Q.
    Bowsher, J.
    Yoo, S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [8] Patient-specific quality assurance for intracranial cases in robotic radiosurgery system
    Koksal, Canan
    Akbas, Ugur
    Kesen, Nazmiye Donmez
    Okutan, Murat
    Bilge, Hatice
    Kemikler, Gonul
    JOURNAL OF BUON, 2018, 23 (01): : 179 - 184
  • [9] Comprehensive quality assurance for stereotactic radiosurgery treatments
    Ramaseshan, R
    Heydarian, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (14) : N199 - N205
  • [10] Patient Specific Quality Assurance for Robotic Radiosurgery
    Blanck, O.
    Breyer, H-W
    Dieterich, S.
    Hildebrandt, G.
    MEDICAL PHYSICS, 2011, 38 (06)