Estimating subcooled liquid vapor pressures and octanol-air partition coefficients of polybrominated diphenyl ethers and their temperature dependence

被引:27
|
作者
Yang, Meng [1 ,3 ]
Li, Yi-Fan [2 ,3 ,4 ,5 ]
Qiao, Li-Na [2 ]
Zhang, Xian-Ming [4 ,5 ]
机构
[1] Dalian Environm Monitoring Ctr, Dalian, Peoples R China
[2] Harbin Inst Technol, Sch Environm, State Key Lab Urban Water Resource & Environm, IJRC AEE,IJRC PTS, Harbin 150090, Heilongjiang, Peoples R China
[3] Dalian Maritime Univ, IJRC PTS, Dalian, Peoples R China
[4] IJRC PTS NA, Toronto, ON M2N 6X9, Canada
[5] IJRC AEE NA, Toronto, ON M2N 6X9, Canada
基金
中国国家自然科学基金;
关键词
PBDEs; Octanol-air partition coefficient (K-OA); Subcooled liquid vapor pressure (P-L); Clausius-Clapeyron coefficients; Gas/particle partitioning; LONG-RANGE TRANSPORT; STRUCTURE-PROPERTY RELATIONSHIPS; SEMIVOLATILE ORGANIC-COMPOUNDS; HENRYS LAW CONSTANTS; PHYSICOCHEMICAL PROPERTIES; POLYCHLORINATED-BIPHENYLS; AQUEOUS SOLUBILITIES; DRY DEPOSITION; GLOBAL AIR; K-OA;
D O I
10.1016/j.scitotenv.2018.02.054
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Both subcooled liquid vapor pressure (P-L) and octanol-air partition coefficient (K-OA ) are widely used as descriptors to predict gas-particle partitioning behavior of semi-volatile organic compounds (SVOCs), such as polybrominated diphenyl ethers (PBDEs). These two descriptors are functions of temperature, which are expressed as the Clausius-Clapeyron equations with the coefficients A(L) and B-L for P-L (log P-L = A(L) + B-L / T) and A(O) and B-O for K-OA (log K-OA A(O) + B-O / T), where T is temperature in K. In this study, a simple equation to relate log K-OA and log P-L (log K-OA = -log P-L + 6.46) was derived, which also links the coefficients of A(L) & B-L and A(O) & B-O. Regression analysis of published data of internal energy Delta U-OA for 22 PBDE congeners with their mole mass was made, leading a regression equation to calculate the internal energy for all 209 PBDE congeners. Three datasets of log K-OA at 25 degrees C for all 209 PBDE congeners were evaluated; the one with the best match with experimentally measurements was selected. Using the datasets and equations described above, we calculated the values of Clausius-Clapeyron coefficients A(O) & B-O and A(L) & B-L for all 209 PBDE congeners at the following steps. First, B-O was computed using the values of Delta U-OA. Next, we calculated the values of A(O) using the values of B-O and the values of log K-OA at 25 degrees C. Finally, the values of the parameter A(L) and B-L were determined for all 209 PBDE congeners. Results are in consistent with data available in the literature and the accuracy of the data were also evaluated. With these Clausius-Clapeyron coefficients, the values of P-L and K-OA at any environmentally relevant temperature can be calculated for all 209 PBDE congeners, and thus provides a quick reference for environmental monitoring and modeling of PBDEs. (C) 2018 Published by Elsevier B.V.
引用
收藏
页码:329 / 337
页数:9
相关论文
共 37 条