Microextraction by packed sorbent followed by ultra high performance liquid chromatography for the fast extraction and determination of six antidepressants in urine

被引:16
作者
Ares Fuentes, Ana Maria [1 ,2 ]
Fernandez, Purificacion [3 ]
Maria Fernandez, Ana [4 ]
Carro, Antonia M. [1 ,2 ]
Antonia Lorenzo, Rosa [1 ,2 ]
机构
[1] Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem, La Coruna, Spain
[2] Univ Santiago de Compostela, Hlth Res Inst Santiago de Compostela IDIS, La Coruna, Spain
[3] Univ Santiago de Compostela, Forens Toxicol Serv, Inst Legal Med, La Coruna, Spain
[4] Drug Addict Assistance Unit, Lugo, Spain
关键词
antidepressants; experimental design; microextraction; packed sorbents; urine; MASS-SPECTROMETRIC METHOD; HYBRID SILICA MONOLITH; HUMAN PLASMA; SIMULTANEOUS QUANTIFICATION; TRICYCLIC ANTIDEPRESSANTS; PHASE MICROEXTRACTION; WHOLE-BLOOD; DRUGS; VALIDATION; FLUOXETINE;
D O I
10.1002/jssc.201900060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The growing use of antidepressants in recent years has led to their increasing presence in forensic analyses. In this work, microextraction by packed sorbent followed by ultra-performance liquid chromatography with photodiode array detection provided a fast method for determining the antidepressants mirtazapine, venlafaxine, escitalopram, fluoxetine, fluvoxamine, and sertraline in human urine. The microextraction conditions (viz., type of sorbent, number of draw-eject extraction cycles or strokes, sample volume and pH, and type and volume of washing solution and eluent) were optimized by using an experimental design. The ensuing analytical method was validated in terms of linearity (25-1000 ng/mL urine), limit of detection (lower than 7.1 ng/mL), limit of quantification (25 ng/mL), precision (4.715.1% as relative standard deviation), and accuracy (80.4-126.1% as mean recovery for four replicate determinations). The proposed method allowed the six target antidepressants to be determined at concentrations from therapeutic to toxic levels. The application to small volumes (300 mu L) of urine afforded fast extraction of the analytes and provided results on a par with those of existing clinical and forensic alternatives.
引用
收藏
页码:2053 / 2061
页数:9
相关论文
共 46 条
[1]   Microextraction by packed sorbent (MEPS): A tutorial [J].
Abdel-Rehim, Mohamed .
ANALYTICA CHIMICA ACTA, 2011, 701 (02) :119-128
[2]  
Agencia Espanola de Medicamentos y Productos Sanitarios, 2015, UT MED ANT ESP DUR P
[3]  
Alves G, 2013, BIOANALYSIS, V5, P1409, DOI [10.4155/BIO.13.92, 10.4155/bio.13.92]
[4]   An improved analytical strategy combining microextraction by packed sorbent combined with ultra high pressure liquid chromatography for the determination of fluoxetine, clomipramine and their active metabolites in human urine [J].
Alves, Vera ;
Goncalves, Joao ;
Conceicao, Carlota ;
Teixeira, Helena M. ;
Camara, Jose S. .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1408 :30-40
[5]  
[Anonymous], 2000, SOLID PHASE EXTRACTI
[6]  
[Anonymous], 2005, INT C HARM TECHN REQ
[7]  
[Anonymous], 2015, MENT HLTH ATL 2014
[8]   Polypyrrole/magnetic nanoparticles composite as an efficient sorbent for dispersive micro-solid-phase extraction of antidepressant drugs from biological fluids [J].
Asgharinezhad, Ali Akbar ;
Karami, Sara ;
Ebrahimzadeh, Homeira ;
Shekari, Nafiseh ;
Jalilian, Niloofar .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2015, 494 (01) :102-112
[9]   Microextraction of antidepressant drugs into syringes packed with a nanocomposite consisting of polydopamine, silver nanoparticles and polypyrrole [J].
Bagheri, Habib ;
Banihashemi, Solmaz ;
Zandian, Faezeh Karimi .
MICROCHIMICA ACTA, 2016, 183 (01) :195-202
[10]   Systematic development of an UPLC-MS/MS method for the determination of tricyclic antidepressants in human urine [J].
Chambers, Erin E. ;
Woodcock, Matthew J. ;
Wheaton, Jessalynn P. ;
Pekol, Teresa M. ;
Diehl, Diane M. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 88 :660-665