HPLC-Diode Array Detector Fingerprints of Various Mentha Species

被引:8
|
作者
Hawryl, Miroslaw A. [1 ]
机构
[1] Med Univ Lublin, Dept Inorgan Chem, PL-20093 Lublin, Poland
关键词
WATER EXTRACTS; LONGIFOLIA;
D O I
10.5740/jaoacint.SGEHawryl
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gradient elution HPLC was applied to develop fingerprints of 12 extracts obtained from selected mint species. The gradient was optimized by use of Merck ChromSword computer software on the basis of retention data of some standard compounds occurring in the investigated plant material. Two column types (RP18 and pentafluorophenyl) and two mobile phases (methanol water and acetonitrile water) were used during the experiments. Fingerprints of all extracts were generated, and on the basis of the fingerprints identification of the mints was possible.
引用
收藏
页码:1268 / 1273
页数:6
相关论文
共 50 条
  • [21] Simultaneous determination of flavonoids, phenolic acids, and coumarins in seven medicinal species by HPLC/diode-array detector
    Andrade, PB
    Seabra, RM
    Valentao, P
    Areias, F
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (18) : 2813 - 2820
  • [22] Separation and identification of phenolic acids from some species of the Asteraceae family using HPLC with a diode array detector
    Markowski, W
    Czapinska, LK
    Jozefczyk, AJ
    Glowniak, K
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (16) : 2497 - 2507
  • [23] Application of dispersive liquid-liquid microextraction for the determination of phenylurea herbicides in water samples by HPLC-diode array detection
    Saraji, Mohammad
    Tansazan, Neda
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (23-24) : 4186 - 4192
  • [24] Analysis of antioxidant compounds in sweet orange peel by HPLC-diode array detection-electrospray ionization mass spectrometry
    Anagnostopoulou, MA
    Kefalas, P
    Kokkalou, E
    Assimopoulou, AN
    Papageorgiou, VP
    BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (02) : 138 - 148
  • [25] Simultaneous determination of hydroxysafflor yellow A and ferulic acid in rat plasma after oral administration of the co-extractum of Rhizoma chuanxiong and Flos Carthami by HPLC-diode array detector
    Qi, Jianping
    Jin, Xuefeng
    Huang, Luosheng
    Ping, Qineng
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (08) : 816 - 822
  • [26] Analysis of commercial multi-vitamin preparation by hplc with diode array detector
    Chu, KO
    Tin, KC
    ANALYTICAL LETTERS, 1998, 31 (15) : 2707 - 2715
  • [27] Determination of PAHs in the marine sediments using HPLC with diode-array detector
    Kowalewska, G
    Toma, B
    CHEMIA ANALITYCZNA, 1996, 41 (05): : 771 - 779
  • [28] CHARACTERIZATION OF RADIATION CURABLE PRODUCTS BY HPLC USING A DIODE ARRAY DETECTOR.
    Doshi, Ravi P.
    Vaickus, Michael J.
    1600, (12):
  • [29] MULTIRESIDUE ANALYSIS OF PHENYLUREA HERBICIDES IN CROPS BY HPLC WITH DIODE-ARRAY DETECTOR
    LAGANA, A
    MARINO, A
    FAGO, G
    MARTINEZ, BP
    ANALUSIS, 1994, 22 (02) : 63 - 69
  • [30] A Validated HPLC-Diode Array Detection Method for Therapeutic Drug Monitoring of Thiopurines in Pediatric Patients: From Bench to Bedside
    Franzin, Martina
    Curci, Debora
    Lucafo, Marianna
    Bramuzzo, Matteo
    Rabusin, Marco
    Fabretto, Antonella
    Addobbati, Riccardo
    Stocco, Gabriele
    Decorti, Giuliana
    METABOLITES, 2022, 12 (12)