共 50 条
High pressure processing pretreatment enhanced the thermosonication inactivation of Alicyclobacillus acidoterrestris spores in orange juice
被引:63
|作者:
Evelyn
[1
,2
]
Silva, Filipa V. M.
[1
]
机构:
[1] Univ Auckland, Dept Chem & Mat Engn, Auckland 1142, New Zealand
[2] Univ Riau, Dept Chem Engn, Pekanbaru 28293, Indonesia
来源:
关键词:
Ultrasound;
Heat;
Thermal;
Pasteurization;
Modelling;
Predictive microbiology;
HEAT-RESISTANCE;
ULTRASONIC-WAVES;
APPLE JUICE;
FRUIT JUICES;
PASTEURIZATION PROCESSES;
HYDROSTATIC PRESSURE;
BACILLUS-SUBTILIS;
BACTERIAL-SPORES;
GERMINATION;
SPOILAGE;
D O I:
10.1016/j.foodcont.2015.11.007
中图分类号:
TS2 [食品工业];
学科分类号:
0832 ;
摘要:
The spoilage of high acid fruit juices and nectars by Alicyclobacillus acidoterrestris is a major concern to juice manufacturers around the world since it is difficult to detect. In this study, thermosonication (ultrasound and heat, TS) and thermal inactivation of A. acidoterrestris spores in pretreated orange juice were carried out and resistance parameters were estimated. First, the effect of TS acoustic energy density (AED, 0.3-20.2 W/mL) on the inactivation at 75 degrees C was investigated. Then, the influence of TS temperature (70-78 degrees C) on the spore inactivation (AED = 20.2 W/mL) was studied. Next, we explored the effect of high pressure processing (HPP) pretreatment of juice on the 20.2 W/mL TS inactivation at the best temperature (78 degrees C). Lastly, the thermal inactivation of spores in juice heat shocked + 1 mm sonicated vs. untreated juice was also investigated. Results of TS showed higher spore inactivation for higher AED (D-75 degrees C-value of 49 min for 20.2 W/mL vs. 217 min for 0.33 W/mL). Lower D-values were obtained at higher temperatures (D-78 degrees C-value of 28 min vs. Dmoc-value of 139 min at 20.2 W/mL). The TS D78.c-value (at 20.2 W/mL) decreased further from 28 min to 14 mm when the orange juice was previously submitted to 600 MPa for 15 min. Thermal treatment alone at 78 degrees C resulted in almost no spore inactivation, whereas the heat shock + ultrasound pretreatment of juice enhanced the thermal inactivation of spores (D-85 degrees C-value decreased from 69 to 29 mm). To conclude, HPP-assisted TS provided the best method for spore inactivation, indicating the benefit of high pressure and power ultrasound technology in addition to heat. TS required at least 8 degrees C lower temperatures than thermal treatments to achieve the same spore inactivation, which could enhance juice quality and energy savings. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:365 / 372
页数:8
相关论文