High-sensitivity microchip electrophoresis determination of inorganic anions and oxalate in atmospheric aerosols with adjustable selectivity and conductivity detection

被引:40
|
作者
Noblitt, Scott D. [1 ]
Schwandner, Florian M. [2 ]
Hering, Susanne V. [3 ]
Collett, Jeffrey L., Jr. [2 ]
Henry, Charles S. [1 ]
机构
[1] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
[2] Colorado State Univ, Dept Atmospher Sci, Ft Collins, CO 80523 USA
[3] Aerosol Dynam Inc, Berkeley, CA USA
基金
美国国家科学基金会;
关键词
Microchip electrophoresis; Atmospheric aerosol; Inorganic anion; Conductivity detection; CAPILLARY-ZONE-ELECTROPHORESIS; AIRBORNE PARTICULATE MATTER; BCR SEQUENTIAL EXTRACTION; ENVIRONMENTAL-SAMPLES; ION CHROMATOGRAPHY; DICARBOXYLIC-ACIDS; ORGANIC-ANIONS; AUTOMATED MEASUREMENT; CARBOXYLIC-ACIDS; AIR-POLLUTION;
D O I
10.1016/j.chroma.2008.12.084
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and selective separation of common anionic constituents of atmospheric aerosols, sulfate, nitrate, chloride, and oxalate, is presented using microchip electrophoresis. The optimized separation is achieved in under 1 min and at low background electrolyte ionic strength (2.9 mM) by combining a metal-binding electrolyte anion (17 mM picolinic acid), a sulfate-binding electrolyte cation (19 mM HEPBS), a zwitterionic surfactant with affinity towards weakly solvated anions (19 mM N-tetradecyl,N,N-dimethyl-3-ammonio-1-propansulfonate), and operation in counter-electroosmotic flow (EOF) mode. The separation is performed at pH 4.7, permitting pH manipulation of oxalate's mobility. The majority of low-concentration organic acids are not observed at these conditions, allowing for rapid subsequent injections without the presence of interfering peaks. Because the mobilities of sulfate, nitrate, and oxalate are independently controlled, other minor constituents of aerosols can be analyzed, including nitrite, fluoride, and formate if desired using similar separation conditions. Contact conductivity detection is utilized, and the limit of detection for oxalate (S/N=3) is 180 nM without stacking. Sensitivity can be increased with field-amplified sample stacking by injecting from dilute electrolyte with a detection limit of 19 nM achieved. The high-sensitivity, counter-EOF operation, and short analysis time make this separation well-suited to continuous online monitoring of aerosol composition. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1503 / 1510
页数:8
相关论文
共 4 条
  • [1] Simultaneous Determination of Inorganic Cations and Anions in Microchip Electrophoresis Using High-voltage Relays
    Zhe Huang
    Mingpeng Yang
    Hui You
    Yang Xie
    Analytical Sciences, 2018, 34 : 801 - 805
  • [2] Simultaneous Determination of Inorganic Cations and Anions in Microchip Electrophoresis Using High-voltage Relays
    Huang, Zhe
    Yang, Mingpeng
    You, Hui
    Xie, Yang
    ANALYTICAL SCIENCES, 2018, 34 (07) : 801 - 805
  • [3] Determination of various inorganic anions and organic acids in the atmospheric particulate matter using capillary zone electrophoresis with indirect UV detection
    Yoshikawa, Kenji
    Shimizu, Miki
    Matsumura, Toshiro
    Sakuragawa, Akio
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2018, 98 (08) : 789 - 798
  • [4] Concurrent determination and separation of inorganic cations and anions in microchip electrophoresis with precisely controlled high-voltage
    Huang, Zhe
    Yang, Mingpeng
    You, Hui
    Xie, Yang
    ELECTROPHORESIS, 2018, 39 (14) : 1802 - 1807