Variable dose rate single-arc IMAT delivered with a constant dose rate and variable angular spacing

被引:28
作者
Tang, Grace [1 ,2 ]
Earl, Matthew A. [1 ]
Yu, Cedric X. [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
[2] UCL, Dept Med Phys & Bioengn, London, England
关键词
DIRECT APERTURE OPTIMIZATION; MODULATED RADIATION-THERAPY; DIODE-ARRAY; IMRT; TOMOTHERAPY;
D O I
10.1088/0031-9155/54/21/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Single-arc intensity-modulated arc therapy (IMAT) has gained worldwide interest in both research and clinical implementation due to its superior plan quality and delivery efficiency. Single-arc IMAT techniques such as the Varian RapidArc (TM) deliver conformal dose distributions to the target in one single gantry rotation, resulting in a delivery time in the order of 2 min. The segments in these techniques are evenly distributed within an arc and are allowed to have different monitor unit (MU) weightings. Therefore, a variable dose-rate (VDR) is required for delivery. Because the VDR requirement complicates the control hardware and software of the linear accelerators (linacs) and prevents most existing linacs from delivering IMAT, we propose an alternative planning approach for IMAT using constant dose-rate (CDR) delivery with variable angular spacing. We prove the equivalence by converting VDR-optimized RapidArc plans to CDR plans, where the evenly spaced beams in the VDR plan are redistributed to uneven spacing such that the segments with larger MU weighting occupy a greater angular interval. To minimize perturbation in the optimized dose distribution, the angular deviation of the segments was restricted to <= +/- 5 degrees. This restriction requires the treatment arc to be broken into multiple sectors such that the local MU fluctuation within each sector is reduced, thereby lowering the angular deviation of the segments during redistribution. The converted CDR plans were delivered with a single gantry sweep as in the VDR plans but each sector was delivered with a different value of CDR. For four patient cases, including two head-and-neck, one brain and one prostate, all CDR plans developed with the variable spacing scheme produced similar dose distributions to the original VDR plans. For plans with complex angular MU distributions, the number of sectors increased up to four in the CDR plans in order to maintain the original plan quality. Since each sector was delivered with a different dose rate, extra mode-up time (xMOT) was needed between the transitions of the successive sectors during delivery. On average, the delivery times of the CDR plans were approximately less than 1 min longer than the treatment times of the VDR plans, with an average of about 0.33 min of xMOT per sector transition. The results have shown that VDR may not be necessary for single-arc IMAT. Using variable angular spacing, VDR RapidArc plans can be implemented into the clinics that are not equipped with the new VDR-enabled machines without compromising the plan quality or treatment efficiency. With a prospective optimization approach using variable angular spacing, CDR delivery times can be further minimized while maintaining the high delivery efficiency of single-arc IMAT treatment.
引用
收藏
页码:6439 / 6456
页数:18
相关论文
共 14 条
  • [1] Sweeping-window arc therapy: an implementation of rotational IMRT with automatic beam-weight calculation
    Cameron, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (18) : 4317 - 4336
  • [2] Comparison of plan quality provided by intensity-modulated arc therapy and helical tomotherapy
    Cao, Daliang
    Holmes, Timothy W.
    Afghan, Muhammad K. N.
    Shepard, David M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01): : 240 - 250
  • [3] Aperture modulated arc therapy
    Crooks, SM
    Wu, XD
    Takita, C
    Watzich, M
    Xing, L
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (10) : 1333 - 1344
  • [4] Inverse planning for intensity-modulated arc therapy using direct aperture optimization
    Earl, MA
    Shepard, DM
    Naqvi, S
    Li, XA
    Yu, CX
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (08) : 1075 - 1089
  • [5] A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery
    Jursinic, PA
    Nelms, BE
    [J]. MEDICAL PHYSICS, 2003, 30 (05) : 870 - 879
  • [6] Evaluation of a 2D diode array for IMRT quality assurance
    Létourneau, D
    Gulam, M
    Yan, D
    Oldham, M
    Wong, JW
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 70 (02) : 199 - 206
  • [7] Volumetric modulated arc therapy: IMRT in a single gantry arc
    Otto, Karl
    [J]. MEDICAL PHYSICS, 2008, 35 (01) : 310 - 317
  • [8] VOLUMETRIC MODULATED ARC THERAPY FOR DELIVERY OF PROSTATE RADIOTHERAPY: COMPARISON WITH INTENSITY-MODULATED RADIOTHERAPY AND THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY
    Palma, David
    Vollans, Emily
    James, Kerry
    Nakano, Sandy
    Moiseenko, Vitali
    Shaffer, Richard
    Mckenzie, Michael
    Morris, James
    Otto, Karl
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 996 - 1001
  • [9] Direct aperture optimization: A turnkey solution for step-and-shoot IMRT
    Shepard, DM
    Earl, MA
    Li, XA
    Naqvi, S
    Yu, C
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1007 - 1018
  • [10] Converting multiple-arc intensity modulated arc therapy into a single arc for efficient delivery
    Tang, G.
    Earl, M. A.
    Luan, S.
    Naqvi, S. A.
    Yu, C. X.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S673 - S673