Multimodality vascular imaging phantoms: A new material for the fabrication of realistic 3D vessel geometries

被引:15
作者
Allard, Louise [1 ]
Soulez, Gilles [2 ,4 ]
Chayer, Boris [1 ]
Treyve, Francois [1 ]
Qin, Zhao [1 ]
Cloutier, Guy [1 ,2 ,3 ]
机构
[1] Univ Montreal, Hosp Res Ctr CRCHUM, Lab Biorheol & Med Ultrason, Montreal, PQ H2L 2W5, Canada
[2] Univ Montreal, Dept Radiol Radiooncol & Nucl Med, Montreal, PQ H3T 1J4, Canada
[3] Univ Montreal, Inst Biomed Engn, Montreal, PQ H3T 1J4, Canada
[4] Univ Montreal Hosp CHUM, Dept Radiol, Montreal, PQ H2L 4M1, Canada
基金
加拿大健康研究院;
关键词
angiocardiography; biomedical MRI; biomedical ultrasonics; computerised tomography; diagnostic radiography; phantoms; ANGIOGRAPHY; ULTRASOUND; REPLICAS; PATIENT; ISOMALT; MARKERS; MODEL; CT;
D O I
10.1118/1.3171692
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multimodality vascular flow phantoms provide a way of testing the geometric accuracy of clinical scanners and optimizing acquisition protocols with easy reproducibility of experimental conditions. This article presents a stereolithography method combined with a lost-material casting technique that eliminates metal residues of cerrolow (a low temperature melting point metallic alloy) left within irregular vessel lumens after casting. These residues potentially cause image artifacts especially in magnetic resonance angiography or flow disturbance. Geometrical accuracies of constructed lumens with isomalt, the proposed material, ranged from 3.3% to 5.7% for vessel diameters of 1.8-7.9 mm, which are comparable to those of lumens constructed with cerrolow that had better accuracies varying from 1.1% to 4.1% (p < 0.02). Examples of geometries mimicking diseased arteries such as an aorta with stenosed renal arteries and an iliac artery with multiple stenoses are presented. This sugar-based isomalt material, combined with phantom designs having fiducial markers visible in digital subtraction angiography, computed tomography angiography, magnetic resonance angiography, and ultrasound [Med. Phys. 31, 1424-1433 (2004)], makes easier the fabrication of complex realistic and accurate replicas of pathological vessels with lumen irregularities.
引用
收藏
页码:3758 / 3763
页数:6
相关论文
共 19 条
  • [1] Flexible tubular replicas of abdominal aortic aneurysms
    Berry, E
    Marsden, A
    Dalgarno, KW
    Kessel, D
    Scott, DJA
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H3) : 211 - 214
  • [2] Thermal properties of isomalt -: A diastereomer mixture
    Borde, B
    Cesàro, A
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2002, 69 (01): : 267 - 280
  • [3] A DSC study of hydrated sugar alcohols.: Isomalt
    Borde, B
    Cesàro, A
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2001, 66 (01): : 179 - 195
  • [4] Geometrical accuracy and fusion of multimodal vascular images: A phantom study
    Boussion, N
    Soulez, G
    De Guise, JA
    Daronat, M
    Qin, Z
    Cloutier, G
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1434 - 1443
  • [5] A multimodality vascular imaging phantom with fiducial markers visible in DSA, CTA, MRA, and ultrasound
    Cloutier, G
    Soulez, G
    Qanadli, SD
    Teppaz, P
    Allard, L
    Qin, Z
    Cloutier, F
    Durand, LG
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1424 - 1433
  • [6] Gailloud P, 1999, AM J NEURORADIOL, V20, P291
  • [7] Comparative Evaluation of the Geometrical Accuracy of Intravascular Magnetic Resonance Imaging: A Phantom Study
    Gilbert, Guillaume
    Soulez, Gilles
    Beaudoin, Gilles
    [J]. ACADEMIC RADIOLOGY, 2009, 16 (08) : 988 - 996
  • [8] HORACEK M, 1997, FOUNDRY TRADE J, V171, P423
  • [9] Investigation of the cooling of spin-casting moulds
    Huan, ZJ
    Jordaan, GD
    [J]. APPLIED THERMAL ENGINEERING, 2003, 23 (01) : 17 - 27
  • [10] Performance evaluation of a medical robotic 3D-ultrasound imaging system
    Janvier, Marie-Ange
    Durand, Louis-Gilles
    Cardinal, Marie-Helene Roy
    Renaud, Isabelle
    Chayer, Boris
    Bigras, Pascal
    de Guise, Jacques
    Soulez, Gilles
    Cloutier, Guy
    [J]. MEDICAL IMAGE ANALYSIS, 2008, 12 (03) : 275 - 290