Assessing Indoor Air Quality Using Chemometric Models

被引:9
|
作者
Azid, Azman [1 ]
Amran, Mohammad Azizi [1 ]
Samsudin, Mohd Saiful [1 ]
Abd Rani, Nurul Latiffah [1 ]
Khalit, Saiful Iskandar [1 ]
Gasim, Muhammad Barzani [1 ,2 ]
Yunus, Kamaruzzaman [3 ]
Saudi, Ahmad Shakir Mohd [4 ]
Amin, Siti Noor Syuhada Muhammad [5 ]
Yusof, Ku Mohd Kalkausar Ku [1 ]
机构
[1] Univ Sultan Zainal Abidin, Fac Bioresources & Food Ind, Besut Campus, Terengganu, Malaysia
[2] Univ Sultan Zainal Abidin, East Coast Environm Res Inst, Gong Badak Campus, Terengganu, Malaysia
[3] Int Islamic Univ Malaysia, Kulliyyah Sci, Pahang, Malaysia
[4] Univ Kuala Lumpur, Inst Med Sci & Technol, Selangor, Malaysia
[5] Univ Sultan Zainal Abidin, Fac Hlth Sci, Gong Badak Campus, Terengganu, Malaysia
来源
POLISH JOURNAL OF ENVIRONMENTAL STUDIES | 2018年 / 27卷 / 06期
关键词
indoor air quality (IAQ); pattern recognition; PCA; PLS-DA; LDA;
D O I
10.15244/pjoes/78154
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objectives of this study are to identify the significant variables and to verify the best statistical method for determining the effect of indoor air quality (IAQ) at 7 different locations in Universiti Sultan Zainal Abidin, Terengganu, Malaysia. The IAQ data were collected using in-situ measurement. Principal component analysis (PCA), partial least squares discriminant analysis (PLS-DA), linear discrimination analysis (LDA), and agglomerative hierarchical clustering (AHC) were used to classify the significant variables as well as to compare the best method for determining IAQ levels. PCA verifies only 4 out of 9 parameters (PM10, PM2.5, PM1.0, and O-3) and is the significant variable in IAQ. The PLS-DA model classifies 89.05% correct of the IAQ variables in each station compared to LDA with only 66.67% correct. AHC identifies three cluster groups, which are highly polluted concentration (HPC), moderately polluted concentration (MPC), and low-polluted concentration (LPC) area. PLS-DA verifies the groups produced by AHC by identifying the variables that affect the quality at each station without being affected by redundancy. In conclusion, PLS-DA is a promising procedure for differentiating the group classes and determining the correct percentage of variables for IAQ.
引用
收藏
页码:2443 / 2450
页数:8
相关论文
共 50 条
  • [41] Indoor air quality in homes, offices and restaurants in Korean urban areas - Indoor/outdoor relationships
    Baek, SO
    Kim, YS
    Perry, R
    ATMOSPHERIC ENVIRONMENT, 1997, 31 (04) : 529 - 544
  • [42] A NUMERICAL AND EXPERIMENTAL STUDY OF THE EFFECT OF USING PERSONAL VENTILATION SYSTEMS ON INDOOR AIR QUALITY IN OFFICE ROOMS
    Saheb, Hussien Aziz
    Mahdi, Ala'a Abbas
    Al-amir, Qusay Rasheed
    FRONTIERS IN HEAT AND MASS TRANSFER, 2021, 16
  • [43] Compliance of Indoor Air Contaminants within the Main Prayer Halls of Mosques in Malacca with Malaysia's Indoor Air Quality Standard
    Rasli, Nur Baitul Izati
    Ismail, Mohd Rodzi
    Ramli, Nor Azam
    Shith, Syabiha
    Nazir, Amni Umirah Mohamad
    Yusof, Noor Faizah Fitri Md
    Zainordin, Nazatul Syadia
    JOURNAL OF CONSTRUCTION IN DEVELOPING COUNTRIES, 2019, 24 (02) : 105 - 121
  • [44] INDOOR MICROBIAL CONTAMINATION AND ITS RELATION TO PHYSICAL INDOOR AIR QUALITY CHARACTERISTICS AT SELECTED LIBRARIES IN PAHANG
    Hizrri, A.
    Khadijah, H.
    Hadry, Noor Faizul N.
    Norhidayah, A.
    Shukri, Mohd M. A.
    JURNAL TEKNOLOGI, 2015, 77 (24): : 51 - 56
  • [45] Measurement of and research on indoor air quality of the modern bamboo house in China
    Xiao, Shubo
    Li, Nianping
    Zhou, Hui
    Su, Qie
    Ni, Ji
    Yang, Ruizhen
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 699 - 705
  • [46] Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates
    Arar, Mohammad
    Jung, Chuloh
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (22)
  • [47] Distributed Control of Multizone HVAC Systems Considering Indoor Air Quality
    Yang, Yu
    Srinivasan, Seshadhri
    Hu, Guoqiang
    Spanos, Costas J.
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2021, 29 (06) : 2586 - 2597
  • [48] Indoor Air Quality (IAQ) Management in Hong Kong: The Way Forward
    Tsang, Tsz-Wun
    Mui, Kwok-Wai
    Wong, Ling-Tim
    ATMOSPHERE, 2024, 15 (05)
  • [49] Investigation of Indoor Air Quality in Several Offices in Baghdad - Case Study
    Al Rikabi, Ihab Jabbar
    Abuelnour, Mohamed Ali
    Abed, Talib Kamil
    Jawad, Abdul Hameed Mohammed
    Omara, Adil A. M.
    2022 8TH INTERNATIONAL ENGINEERING CONFERENCE ON SUSTAINABLE TECHNOLOGY AND DEVELOPMENT (IEC), 2022, : 78 - 82
  • [50] Indoor Air Quality Levels in Schools: Role of Student Activities and No Activities
    Settimo, Gaetano
    Indinnimeo, Luciana
    Inglessis, Marco
    De Felice, Marco
    Morlino, Roberta
    di Coste, Annalisa
    Fratianni, Alessandra
    Avino, Pasquale
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (18) : 1 - 17