Assessing Indoor Air Quality Using Chemometric Models

被引:9
|
作者
Azid, Azman [1 ]
Amran, Mohammad Azizi [1 ]
Samsudin, Mohd Saiful [1 ]
Abd Rani, Nurul Latiffah [1 ]
Khalit, Saiful Iskandar [1 ]
Gasim, Muhammad Barzani [1 ,2 ]
Yunus, Kamaruzzaman [3 ]
Saudi, Ahmad Shakir Mohd [4 ]
Amin, Siti Noor Syuhada Muhammad [5 ]
Yusof, Ku Mohd Kalkausar Ku [1 ]
机构
[1] Univ Sultan Zainal Abidin, Fac Bioresources & Food Ind, Besut Campus, Terengganu, Malaysia
[2] Univ Sultan Zainal Abidin, East Coast Environm Res Inst, Gong Badak Campus, Terengganu, Malaysia
[3] Int Islamic Univ Malaysia, Kulliyyah Sci, Pahang, Malaysia
[4] Univ Kuala Lumpur, Inst Med Sci & Technol, Selangor, Malaysia
[5] Univ Sultan Zainal Abidin, Fac Hlth Sci, Gong Badak Campus, Terengganu, Malaysia
来源
POLISH JOURNAL OF ENVIRONMENTAL STUDIES | 2018年 / 27卷 / 06期
关键词
indoor air quality (IAQ); pattern recognition; PCA; PLS-DA; LDA;
D O I
10.15244/pjoes/78154
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objectives of this study are to identify the significant variables and to verify the best statistical method for determining the effect of indoor air quality (IAQ) at 7 different locations in Universiti Sultan Zainal Abidin, Terengganu, Malaysia. The IAQ data were collected using in-situ measurement. Principal component analysis (PCA), partial least squares discriminant analysis (PLS-DA), linear discrimination analysis (LDA), and agglomerative hierarchical clustering (AHC) were used to classify the significant variables as well as to compare the best method for determining IAQ levels. PCA verifies only 4 out of 9 parameters (PM10, PM2.5, PM1.0, and O-3) and is the significant variable in IAQ. The PLS-DA model classifies 89.05% correct of the IAQ variables in each station compared to LDA with only 66.67% correct. AHC identifies three cluster groups, which are highly polluted concentration (HPC), moderately polluted concentration (MPC), and low-polluted concentration (LPC) area. PLS-DA verifies the groups produced by AHC by identifying the variables that affect the quality at each station without being affected by redundancy. In conclusion, PLS-DA is a promising procedure for differentiating the group classes and determining the correct percentage of variables for IAQ.
引用
收藏
页码:2443 / 2450
页数:8
相关论文
共 50 条
  • [21] Improving indoor air quality by using the new generation of corrugated cardboard-based filters
    Candiani, Gabriele
    Del Curto, Barbara
    Cigada, Alberto
    JOURNAL OF APPLIED BIOMATERIALS & FUNCTIONAL MATERIALS, 2012, 10 (02): : 157 - 162
  • [22] Classifying Sources Influencing Indoor Air Quality (IAQ) Using Artificial Neural Network (ANN)
    Mad Saad, Shaharil
    Andrew, Allan Melvin
    Shakaff, Ali Yeon Md
    Saad, Abdul Rahman Mohd
    Kamarudin, Azman Muhamad Yusof
    Zakaria, Ammar
    SENSORS, 2015, 15 (05): : 11665 - 11684
  • [23] Preliminary study on the effect of using heat-not-burn tobacco products on indoor air quality
    Yu, Seong-Ji
    Kwon, Min-Ku
    Choi, Wonsik
    Son, Youn-Suk
    ENVIRONMENTAL RESEARCH, 2022, 212
  • [24] Assessing chemometric models developed using Raman spectroscopy and fatty acid data for Northern and Southern Australian beef production systems
    Logan, Bridgette G.
    Hopkins, David L.
    Schmidtke, Leigh M.
    Fowler, Stephanie M.
    MEAT SCIENCE, 2022, 187
  • [25] Apply grey relating method to evaluate indoor air quality
    Han, J
    Zhang, JW
    Zhang, GQ
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 183 - 186
  • [26] A systematic indoor air quality audit approach for public buildings
    Ehsan Asadi
    Manuel C. Gameiro da Silva
    J. J. Costa
    Environmental Monitoring and Assessment, 2013, 185 : 865 - 875
  • [27] Investigation of Indoor Air Quality inside Houses From UAE
    Bani Mfarrej, Manar Fawzi
    Qafisheh, Nida Ali
    Bahloul, Moez Mohamed
    AIR SOIL AND WATER RESEARCH, 2020, 13
  • [28] Indoor air quality audit implementation in a hotel building in Portugal
    Asadi, Ehsan
    Costa, J. J.
    da Silva, Manuel Gameiro
    BUILDING AND ENVIRONMENT, 2011, 46 (08) : 1617 - 1623
  • [29] Indoor air quality in sports center: Assessment of gaseous pollutants
    Bralewska, Karolina
    Rogula-Kozlowska, Wioletta
    Bralewski, Adrian
    BUILDING AND ENVIRONMENT, 2022, 208
  • [30] A systematic indoor air quality audit approach for public buildings
    Asadi, Ehsan
    Gameiro da Silva, Manuel C.
    Costa, J. J.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2013, 185 (01) : 865 - 875