Assessing Indoor Air Quality Using Chemometric Models

被引:9
|
作者
Azid, Azman [1 ]
Amran, Mohammad Azizi [1 ]
Samsudin, Mohd Saiful [1 ]
Abd Rani, Nurul Latiffah [1 ]
Khalit, Saiful Iskandar [1 ]
Gasim, Muhammad Barzani [1 ,2 ]
Yunus, Kamaruzzaman [3 ]
Saudi, Ahmad Shakir Mohd [4 ]
Amin, Siti Noor Syuhada Muhammad [5 ]
Yusof, Ku Mohd Kalkausar Ku [1 ]
机构
[1] Univ Sultan Zainal Abidin, Fac Bioresources & Food Ind, Besut Campus, Terengganu, Malaysia
[2] Univ Sultan Zainal Abidin, East Coast Environm Res Inst, Gong Badak Campus, Terengganu, Malaysia
[3] Int Islamic Univ Malaysia, Kulliyyah Sci, Pahang, Malaysia
[4] Univ Kuala Lumpur, Inst Med Sci & Technol, Selangor, Malaysia
[5] Univ Sultan Zainal Abidin, Fac Hlth Sci, Gong Badak Campus, Terengganu, Malaysia
来源
POLISH JOURNAL OF ENVIRONMENTAL STUDIES | 2018年 / 27卷 / 06期
关键词
indoor air quality (IAQ); pattern recognition; PCA; PLS-DA; LDA;
D O I
10.15244/pjoes/78154
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objectives of this study are to identify the significant variables and to verify the best statistical method for determining the effect of indoor air quality (IAQ) at 7 different locations in Universiti Sultan Zainal Abidin, Terengganu, Malaysia. The IAQ data were collected using in-situ measurement. Principal component analysis (PCA), partial least squares discriminant analysis (PLS-DA), linear discrimination analysis (LDA), and agglomerative hierarchical clustering (AHC) were used to classify the significant variables as well as to compare the best method for determining IAQ levels. PCA verifies only 4 out of 9 parameters (PM10, PM2.5, PM1.0, and O-3) and is the significant variable in IAQ. The PLS-DA model classifies 89.05% correct of the IAQ variables in each station compared to LDA with only 66.67% correct. AHC identifies three cluster groups, which are highly polluted concentration (HPC), moderately polluted concentration (MPC), and low-polluted concentration (LPC) area. PLS-DA verifies the groups produced by AHC by identifying the variables that affect the quality at each station without being affected by redundancy. In conclusion, PLS-DA is a promising procedure for differentiating the group classes and determining the correct percentage of variables for IAQ.
引用
收藏
页码:2443 / 2450
页数:8
相关论文
共 50 条
  • [1] Monitoring and prediction of indoor air quality (IAQ) in subway or metro systems using season dependent models
    Kim, MinJeong
    SankaraRao, B.
    Kang, OnYu
    Kim, JeongTai
    Yoo, ChangKyoo
    ENERGY AND BUILDINGS, 2012, 46 : 48 - 55
  • [2] Identification Source of Variation on Regional Impact of Air Quality Pattern Using Chemometric
    Azid, Azman
    Juahir, Hafizan
    Ezani, Ezureen
    Toriman, Mohd Ekhwan
    Endut, Azizah
    Rahman, Mohd Nordin Abdul
    Yunus, Kamaruzzaman
    Kamarudin, Mohd Khairul Amri
    Hasnam, Che Noraini Che
    Saudi, Ahmad Shakir Mohd
    Umar, Roslan
    AEROSOL AND AIR QUALITY RESEARCH, 2015, 15 (04) : 1545 - 1558
  • [3] Evaluation on four sampling schemes for assessing indoor air quality
    Wong, L. T.
    Mui, K. W.
    BUILDING AND ENVIRONMENT, 2007, 42 (03) : 1119 - 1125
  • [4] Indoor air quality in schools
    de Gennaro, Gianluigi
    Dambruoso, Paolo Rosario
    Loiotile, Annamaria Demarinis
    Di Gilio, Alessia
    Giungato, Pasquale
    Tutino, Maria
    Marzocca, Annalisa
    Mazzone, Antonio
    Palmisani, Jolanda
    Porcelli, Francesca
    ENVIRONMENTAL CHEMISTRY LETTERS, 2014, 12 (04) : 467 - 482
  • [5] Indoor air quality in schools
    Gianluigi de Gennaro
    Paolo Rosario Dambruoso
    Annamaria Demarinis Loiotile
    Alessia Di Gilio
    Pasquale Giungato
    Maria Tutino
    Annalisa Marzocca
    Antonio Mazzone
    Jolanda Palmisani
    Francesca Porcelli
    Environmental Chemistry Letters, 2014, 12 : 467 - 482
  • [6] Indoor Air Quality Management in Dubai: Assessing the Efficacy of Air Purifiers, Photocatalysts, and Window Ventilation in Reducing HCHO
    Jung, Chuloh
    Alshamasi, Shams Mohammed
    BUILDINGS, 2024, 14 (09)
  • [7] Assessing the impact of kitchen hoods and ventilation openings on indoor air quality post-cooking
    Chen, Shou-Wang
    Chang, Chao-Yen
    Chan, Ying-Chieh
    JOURNAL OF BUILDING ENGINEERING, 2025, 100
  • [8] Using carbon dioxide concentration to assess indoor air quality in offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    INDOOR AND BUILT ENVIRONMENT, 2008, 17 (03) : 213 - 219
  • [9] Indoor Air Quality Benchmarking for Air Conditioned Offices
    Hui, Pui-shan
    Wong, Ling-tim
    Mui, Kwok-wai
    CLEAN-SOIL AIR WATER, 2009, 37 (06) : 481 - 486
  • [10] Assessing the impact of ventilation systems on indoor air quality: a mock-up experiment in Dubai
    Jung, Chuloh
    El Samanoudy, Gamal
    Alqassimi, Nahla
    Sherzad, Mohammed
    FRONTIERS IN BUILT ENVIRONMENT, 2023, 9