One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays

被引:193
作者
Reader, AJ [1 ]
Ally, S
Bakatselos, F
Manavaki, R
Walledge, RJ
Jeavons, AP
Julyan, PJ
Zhao, S
Hastings, DL
Zweit, J
机构
[1] Univ Manchester, DIAS, Manchester M60 1QD, Lancs, England
[2] Oxford Positron Syst, Oxford OX6 8SY, England
[3] Paterson Inst Canc Res, Manchester, Lancs, England
[4] Christie Hosp NHS Trust, Manchester M20 4BX, Lancs, England
关键词
iterative image reconstruction; list mode; positron emission tomography (PET);
D O I
10.1109/TNS.2002.1039550
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High-resolution three-dimensional (3-D) positron emission tomography (PET) scanners with high count rate performance, such as the quad-high density avalanche chamber (HIDAC), place new demands on image reconstruction algorithms due to the large quantities of high-precision list-mode data which are produced. Therefore, a reconstruction algorithm is required which can, in a practical time frame, reconstruct into very large image arrays (submillimeter voxels, which range over a large field of view) whilst preferably retaining the precision of the data. This work presents an algorithm which meets these demands: one-pass list-mode expectation maximization (OPL-EM) algorithm. The algorithm operates directly on list-mode data, passes through the data once only, accounts for finite resolution effects in the system model, and can also include regularization. The algorithm performs multiple image updates during its single pass through the list-mode data, corresponding to the number of subsets that the data have been split into. The algorithm has been assessed using list-mode data from a quad-HIDAC and is compared to the analytic reconstruction method 3-D reprojection (RP) with 3-D filtered backprojection.
引用
收藏
页码:693 / 699
页数:7
相关论文
共 15 条
  • [1] List-mode likelihood
    Barrett, HH
    White, T
    Parra, LC
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (11): : 2914 - 2923
  • [2] LMIRA: List-mode iterative reconstruction algorithm for SPECT
    Bouwens, L
    Van de Walle, R
    Gifford, H
    King, M
    Lemahieu, I
    Dierckx, RA
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1364 - 1370
  • [3] Likelihood maximization for list-mode emission tomographic image reconstruction
    Byrne, C
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (10) : 1084 - 1092
  • [4] List-mode maximum-likelihood reconstruction applied to positron emission mammography (PEM) with irregular sampling
    Huesman, RH
    Klein, GJ
    Moses, WW
    Qi, JY
    Reutter, BW
    Virador, PRG
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 532 - 537
  • [5] A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals
    Jeavons, AP
    Chandler, RA
    Dettmar, CAR
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 468 - 473
  • [6] ANALYTIC 3D IMAGE-RECONSTRUCTION USING ALL DETECTED EVENTS
    KINAHAN, PE
    ROGERS, JG
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 964 - 968
  • [7] FAST GRADIENT-BASED METHODS FOR BAYESIAN RECONSTRUCTION OF TRANSMISSION AND EMISSION PET IMAGES
    MUMCUOGLU, EU
    LEAHY, R
    CHERRY, SR
    ZHOU, ZY
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) : 687 - 701
  • [8] List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET
    Parra, L
    Barrett, HH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (02) : 228 - 235
  • [9] Patton JA, 1999, J NUCL MED, V40, p294P
  • [10] Fast accurate iterative reconstruction for low-statistics positron volume imaging
    Reader, AJ
    Erlandsson, K
    Flower, MA
    Ott, RJ