A static beam delivery device for fast scanning proton arc-therapy

被引:13
作者
Nesteruk, K. P. [1 ]
Bolsi, A. [1 ]
Lomax, A. J. [1 ,2 ]
Meer, D. [1 ]
van de Water, S. [1 ]
Schippers, J. M. [1 ]
机构
[1] Paul Scherrer Inst, Villigen, Switzerland
[2] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
关键词
proton-arc therapy; static beam delivery device; fast dose delivery; IMPLEMENTATION;
D O I
10.1088/1361-6560/abe02b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Arc-therapy is a dose delivery technique regularly applied in photon radiation therapy, and is currently subject of great interest for proton therapy as well. In this technique, proton beams are aimed at a tumor from different continuous ranges of incident directions (so called 'arcs'). This technique can potentially yield a better dose conformity around the tumor and a very low dose in the surrounding healthy tissue. Currently, proton-arc therapy is performed by rotating a proton gantry around the patient, adapting the normally used dose-delivery method to the arc-specific motion of the gantry. Here we present first results from a feasibility study of the conceptual design of a new static fast beam delivery device/system for proton-arc therapy, which could be used instead of a gantry. In this novel concept, the incident angle of proton beams can be set rapidly by only changing field strengths of small magnets. This device eliminates the motion of the heavy gantry and related hardware. Therefore, a reduction of the total treatment time is expected. In the feasibility study presented here, we concentrate on the concept of the beam transport. Based on several simple, but realistic assumptions and approximations, proton tracking calculations were performed in a 3D magnetic field map, to calculate the beam transport in this device and to investigate and address several beam-optics challenges. We propose and simulate corresponding solutions and discuss their outcomes. To enable the implementation of some usually applied techniques in proton therapy, such as pencil beam scanning, energy modulation and beam shaping, we present and discuss our proposals. Here we present the concept of a new idea to perform fast proton arc-scanning and we report on first results of a feasibility study. Based on these results, we propose several options and next steps in the design.
引用
收藏
页数:15
相关论文
共 28 条
[1]  
Adelmann A., 2008, PSIPR0802
[2]  
[Anonymous], 1987, OPTICS CHARGED PARTI
[3]  
BERTOLET A, 2020, PHYS, V65, DOI DOI 10.1088/1361-6560/ab9455
[4]   COMPUTATIONAL ASPECTS OF OPTICS DESIGN AND SIMULATION - COSY INFINITY [J].
BERZ, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 298 (1-3) :473-479
[5]  
Bizzocchi N., 2020, PENCIL BEAM SC UNPUB
[6]   Development and Clinical Implementation of a Universal Bolus to Maintain Spot Size During Delivery of Base of Skull Pencil Beam Scanning Proton Therapy [J].
Both, Stefan ;
Shen, Jiajian ;
Kirk, Maura ;
Lin, Liyong ;
Tang, Shikui ;
Alonso-Basanta, Michelle ;
Lustig, Robert ;
Lin, Haibo ;
Deville, Curtiland ;
Hill-Kayser, Christine ;
Tochner, Zelig ;
McDonough, James .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 (01) :79-84
[7]   Complexity metrics for IMRT and VMAT plans: a review of current literature and applications [J].
Chiavassa, Sophie ;
Bessieres, Igor ;
Edouard, Magali ;
Mathot, Michel ;
Moignier, Alexandra .
BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1102)
[8]  
Craddock, 2009, P PART ACC C PAC09, P5041
[9]  
Deasy JO, 1997, PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, P406
[10]   Spot-Scanning Proton Arc (SPArc) Therapy: The First Robust and Delivery-Efficient Spot-Scanning Proton Arc Therapy [J].
Ding, Xuanfeng ;
Li, Xiaoqiang ;
Zhang, J. Michele ;
Kabolizadeh, Peyman ;
Stevens, Craig ;
Yan, Di .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (05) :1107-1116