Assessment of The Committed Effective Dose Equivalent and Its Uncertainty From Incidental Internal Tritium Exposure

被引:0
|
作者
Vostrotin, V. V. [1 ]
Yanov, A. Y. [1 ]
Finashov, L., V [1 ]
机构
[1] Southern Ural Biophys Inst, Ozyorskoe Shosse 19, Ozyorsk, Chelyabinsk Reg, Russia
关键词
BIOLOGICAL HALF-LIFE; ACCIDENTAL INTAKE; TRITIATED-WATER;
D O I
10.1093/rpd/ncac078
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of the study was to estimate the committed effective dose equivalent from internal tritium exposure and its uncertainty in case of tritium incident at Mayak PA. According to worker's self-report, he had been exposed as a result of pouring "heavy" water over himself while performing technological operation in September 2019. Two-component exponential model of tritiated water (HTO) excretion including fast and slow phases was used to describe HTO content in the body. The individual's specific value of tritium biological half-life in the fast phase was 8.9 days, which is close to the average value of 10 days in the ICRP model. The slow-phase HTO excretion fraction is two orders of magnitude lower than the corresponding value in the ICRP model. The calculated committed effective dose equivalent (CEDE) due to tritium intake (7.4 mSv) depended mostly on fast-phase excretion. The uncertainty factor calculated as ratio of the 97.5% quantile and the mean value was equal to 1.14. The contribution of the slow-phase excretion to the CEDE due to internal exposure was as low as from 0.1 to 0.2% of total CEDE. This demonstrates that after the case of a single intake of tritium, which we studied, the CEDE is determined mostly by the excretion in the fast phase. The metabolized organically bound tritium dose fraction was in the range from 0.3 to 2.0%. The use of all the results of the measurement of HTO activity concentration in urine made it possible to obtain a lower estimate of the uncertainty of the CEDE of internal exposure in comparison with the use of only the first measurement result.
引用
收藏
页码:448 / 453
页数:6
相关论文
共 50 条
  • [31] CALCULATION OF EFFECTIVE DOSE-EQUIVALENT RESPONSES FOR EXTERNAL EXPOSURE FROM RESIDUAL PHOTON EMITTERS IN SOIL
    CHEN, SY
    HEALTH PHYSICS, 1991, 60 (03): : 411 - 426
  • [32] Use of internal dose biomarkers for assessment of lead exposure and its correlations with genetic polymorphisms in children
    Almeida, Glauce
    Gerlach, Raquel
    TOXICOLOGY LETTERS, 2009, 189 : S154 - S154
  • [33] An assessment of committed effective dose and lifetime cancer risk due to the ingestion of infant milk
    da Silva, Lucas Faria
    Dutra Garcez, Ricardo Washington
    Fernandes, Thais Santos
    Lopes, Jose Marques
    Mello, Camila Rodrigues
    da Silva, Leandro Barbosa
    de Souza Paiva, Alexandre Kuster
    da Silva, Ademir Xavier
    APPLIED RADIATION AND ISOTOPES, 2022, 190
  • [34] Effective dose equivalent and effective dose for photon exposures from point and disk sources on the floor
    Kim, CH
    Reece, WD
    Poston, JW
    HEALTH PHYSICS, 1998, 75 (02): : 170 - 178
  • [35] Total effective dose equivalent assessment after exposure to high-level natural radiation using the RESRAD code
    Ziajahromi, Shima
    Khanizadeh, Meysam
    Nejadkoorki, Farhad
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2014, 186 (03) : 1907 - 1915
  • [36] Total effective dose equivalent assessment after exposure to high-level natural radiation using the RESRAD code
    Shima Ziajahromi
    Meysam Khanizadeh
    Farhad Nejadkoorki
    Environmental Monitoring and Assessment, 2014, 186 : 1907 - 1915
  • [37] Explaining radiation dose exposure. The role of the banana equivalent dose compared to the effective dose in patient communication
    Stein, T.
    Schuermann, T.
    Bamberg, F.
    Mueller-Peltzer, K.
    RADIOLOGIE, 2023, 63 (09): : 679 - 687
  • [38] ESTIMATION OF EFFECTIVE DOSE EQUIVALENT FROM INHALATION OF THORON AND ITS DAUGHTER PRODUCTS AT A THORIUM PLANT
    GOHEL, CO
    PUSHPARAJA
    ABANI, MC
    NAMBIAR, PPVJ
    IYER, MR
    RADIATION PROTECTION DOSIMETRY, 1991, 38 (04) : 287 - 290
  • [39] A study of 210Po in atmospheric aerosol of Shenzhen and its committed effective dose
    Liu, Guo-Qing (liugq@szu.edu.cn), 1600, Chinese Society for Environmental Sciences (37):
  • [40] Improvement of dose assessment for internal lung exposure from plutonium using a microdosimetric approach
    Romanov, S.A.
    Khan, F.F.
    Gil'met, R.A.
    Nifatov, A.P.
    Zajtseva, E.V.
    Meditsinskaya Radiologiya I Radiatsionnaya Bezopasnost', 2001, 46 (06): : 58 - 65