'Fast-implantable' aortic valve implantation and concomitant mitral procedures

被引:10
作者
Ferrari, Enrico [1 ,2 ]
Siniscalchi, Giuseppe [2 ]
Marinakis, Sotirios [1 ]
Berdajs, Denis [2 ]
von Segesser, Ludwig [3 ]
机构
[1] Sion Hosp, Cardiac Surg Unit, CH-1951 Sion, Switzerland
[2] Univ Lausanne, Cardiac Surg Unit, Lausanne, Switzerland
[3] Univ Lausanne, Cardiovasc Res Unit, Lausanne, Switzerland
关键词
Aortic and mitral valve replacement; Mitral valve repair; Bio-prosthesis; Redo cardiac surgery; REPLACEMENT; STENOSIS; SYSTEM;
D O I
10.1093/icvts/ivu204
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mitral ring is already in place and a surgical aortic valve replacement becomes necessary, or when older high-risk patients require concomitant mitral and aortic procedures, the new 'fast-implantable' aortic valve system (Intuity T valve, Edwards Lifesciences, Irvine, CA, USA) can represent a smart alternative to standard aortic bioprosthesis. Unfortunately, this is still controversial (risk of interference). However, transcatheter aortic valve replacements have been performed in patients with previously implanted mitral valves or mitral rings. Interestingly, we learned that there is no interference (or not significant interference) among the standard valve and the stent valve. Consequently, we can assume that a fast-implantable valve can also be safely placed next to a biological mitral valve or next to a rigid mitral ring without risks of distortion, malpositioning, high gradient or paravalvular leak. This paper describes two cases: a concomitant Intuity T aortic valve and bioprosthetic mitral valve implantation and a concomitant Intuity T aortic valve and mitral ring implantation.
引用
收藏
页码:682 / 684
页数:3
相关论文
共 5 条
[1]   Current trends in aortic valve replacement: development of the rapid deployment EDWARDS INTUITY valve system [J].
Borger, Michael A. ;
Dohmen, Pascal ;
Misfeld, Martin ;
Mohr, Friedrich W. .
EXPERT REVIEW OF MEDICAL DEVICES, 2013, 10 (04) :461-470
[2]   Self-expandable transcatheter aortic valve implantation for aortic stenosis after mitral valve surgery [J].
Bruschi, Giuseppe ;
De Marco, Federico ;
Barosi, Alberto ;
Colombo, Paola ;
Botta, Luca ;
Nonini, Sandra ;
Martinelli, Luigi ;
Klugmann, Silvio .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 17 (01) :90-95
[3]   One-year outcomes of the Surgical Treatment of Aortic Stenosis With a Next Generation Surgical Aortic Valve (TRITON) trial: A prospective multicenter study of rapid-deployment aortic valve replacement with the EDWARDS INTUITY Valve System [J].
Kocher, Alfred A. ;
Laufer, Guenther ;
Haverich, Axel ;
Shrestha, Malakh ;
Walther, Thomas ;
Misfeld, Martin ;
Kempfert, Joerg ;
Gillam, Linda ;
Schmitz, Christoph ;
Wahlers, Thorsten C. ;
Wippermann, Jens ;
Mohr, Friedrich W. ;
Roth, Matthias ;
Skwara, Adalbert ;
Rahmanian, Parwis ;
Wiedemann, Dominik ;
Borger, Michael A. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (01) :110-116
[4]   CLINICAL AND NECROPSY OBSERVATIONS EARLY AFTER SIMULTANEOUS REPLACEMENT OF THE MITRAL AND AORTIC VALVES [J].
ROBERTS, WC ;
SULLIVAN, MF .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 58 (11) :1067-1084
[5]   Transapical Transcatheter Aortic Valve Implantation in the Presence of a Mitral Prosthesis [J].
Soon, Jia Lin ;
Ye, Jian ;
Lichtenstein, Samuel V. ;
Wood, David ;
Webb, John G. ;
Cheung, Anson .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (07) :715-721