Determination of heavy metals in wines by anodic stripping voltammetry with thick-film modified electrode

被引:85
|
作者
Brainina, KZ
Stozhko, NY
Belysheva, GM
Inzhevatova, OV
Kolyadina, LI
Cremisini, C
Galletti, M
机构
[1] Ural State Univ Econ, Chair Chem, Ekaterinburg 620219, Russia
[2] ENEA, CR Casaccia, Analyt Methods Environm Monitoring, I-00060 Rome, Italy
关键词
anodic stripping voltammetry; modified thick-film graphite electrode; heavy metals; wine;
D O I
10.1016/j.aca.2004.03.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method has been developed for determination of copper, lead, cadmium and zinc concentration in dry wines by stripping voltammetric with a thick-film modified graphite-containing electrode (TFMGE). This method does not require the preliminary acid digestion of the sample or other approaches for the destruction of organic substances. The optimal conditions for the determination of these elements in wines have been chosen. Supporting electrolyte was 0.5 M HCl for Cu, Pb and Cd, and 0.1 M acetate buffer (pH 5.5) and 0.35 M NaCl for Zn. The accumulation potential was -0.8 V for Cu, -1.2 V for Ph and Cd, and -1.4 V for Zn. The degree of wine dilution with the supporting electrolyte was 1:1.1 for Cu, Ph and Cd, and 1:50 for Zn. The accumulation time was 30-60 s for copper, 120 s for lead and cadmium, and 10-30 s for zinc. Results obtained under the chosen conditions with the use of TFMGE were compared with those obtained using ICP-MS for the final determination of the selected elements. Moreover, it was shown that the proposed method provided better reproducibility than methods involving wine decomposition. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:227 / 234
页数:8
相关论文
共 50 条
  • [1] Anodic stripping voltammetry for direct determination of heavy metals in bovine seminal plasma using thick film modified graphite electrodes
    Skiba, Tatyana, V
    Gou, Hueyhuey
    MICROCHEMICAL JOURNAL, 2019, 147 : 818 - 823
  • [2] The determination of heavy metals in human gallstone by anodic stripping voltammetry
    Bouropoulos, N
    Karavias, D
    Koutsoukos, PG
    ANALUSIS, 1996, 24 (03) : 89 - 92
  • [3] Determination of heavy metals in honey by anodic stripping voltammetry at microelectrodes
    Sanna, G
    Pilo, MI
    Piu, PC
    Tapparo, A
    Seeber, R
    ANALYTICA CHIMICA ACTA, 2000, 415 (1-2) : 165 - 173
  • [4] Simultaneous Heavy Metal Determination in Mussels by Anodic Stripping Voltammetry (ASV) Using Thick Film Modified Graphite Electrodes
    Skiba, Tatyana V.
    Medvedev, Nikolay S.
    Tsygankova, Alphya R.
    Panasenko, Yuriy V.
    ANALYTICAL LETTERS, 2024, 57 (02) : 237 - 249
  • [5] Determination of trace metals by anodic stripping voltammetry using a bismuth-modified carbon nanotube electrode
    Hwang, Gil Ho
    Han, Won Kyu
    Park, Joon Shik
    Kang, Sung Goon
    TALANTA, 2008, 76 (02) : 301 - 308
  • [6] SQUARE-WAVE ANODIC STRIPPING VOLTAMMETRY (SWASV) FOR THE DETERMINATION OF ECOTOXIC METALS, USING A BISMUTH-FILM ELECTRODE
    Anastasiadou, Z. D.
    Sipaki, I.
    Jannakoudakis, P. D.
    Girousi, S. T.
    ANALYTICAL LETTERS, 2011, 44 (05) : 761 - 777
  • [7] Anodic stripping voltammetry of heavy metals at nanocrystalline boron-doped diamond electrode
    El Tall, Omar
    Jaffrezic-Renault, Nicole
    Sigaud, Monique
    Vittori, Olivier
    ELECTROANALYSIS, 2007, 19 (11) : 1152 - 1159
  • [8] Heated mercury film electrode for anodic stripping voltammetry
    Jasinski, M
    Kirbs, A
    Schmehl, M
    Gründler, P
    ELECTROCHEMISTRY COMMUNICATIONS, 1999, 1 (01) : 26 - 28
  • [9] Determination of manganese in drinking water by anodic stripping voltammetry at a mercury film electrode
    Panascikaite, Erika
    Armalis, Saulius
    CHEMIJA, 2011, 22 (01): : 41 - 45
  • [10] Multicommutated Anodic Stripping Voltammetry at Tubular Bismuth Film Electrode for Lead Determination in Gunshot Residues
    Rodriguez, Jose A.
    Ibarra, Israel S.
    Galan-Vidal, Carlos A.
    Vega, Marisol
    Barrado, Enrique
    ELECTROANALYSIS, 2009, 21 (3-5) : 452 - 458