Obtaining breathing patterns from any sequential thoracic x-ray image set

被引:43
作者
Kavanagh, Anthony [1 ]
Evans, Philip M.
Hansen, Vibeke N.
Webb, Steve
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
关键词
BEAM COMPUTED-TOMOGRAPHY; RADIOTHERAPY;
D O I
10.1088/0031-9155/54/16/003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A technique is presented to allow a breathing pattern to be obtained from any multi-slice CT, cone-beam or other series of sequential chest x-ray image sets. The technique requires no extra signals to be recorded and does not need specific external or internal oscillating structures to be visible in the field of view. The breathing pattern is instead acquired from analysing the variation in pixel values between projection images. For cone-beam image sets, slowly varying changes, due to an angular attenuation dependence, must be corrected before the breathing trace analysis can begin. All the results of the new technique were checked visually and were in good agreement. If the studied image set could be analysed using the existing 'Amsterdam shroud' technique, then the results it provided were also used for comparison. In cases that allowed comparison by both techniques, the results were in agreement. The new technique was also shown to provide a usable signal when applied to cardiac motion.
引用
收藏
页码:4879 / 4888
页数:10
相关论文
共 10 条
[1]   Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers [J].
Berbeco, RI ;
Mostafavi, H ;
Sharp, GC ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19) :4481-4490
[2]  
KEALL P, 2001, MED PHYS, V28, P1252
[3]   Respiration gated radiotherapy treatment: A technical study [J].
Kubo, HD ;
Hill, BC .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01) :83-91
[4]   High temporal resolution and streak-free four-dimensional cone-beam computed tomography [J].
Leng, Shuai ;
Tang, Jie ;
Zambelli, Joseph ;
Nett, Brian ;
Tolakanahalli, Ranjini ;
Chen, Guang-Hong .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20) :5653-5673
[5]   Streaking artifacts reduction in four-dimensional cone-beam computed tomography [J].
Leng, Shuai ;
Zambelli, Joseph ;
Tolakanahalli, Ranjini ;
Nett, Brian ;
Munro, Peter ;
Star-Lack, Joshua ;
Paliwal, Bhudatt ;
Chena, Guang-Hong .
MEDICAL PHYSICS, 2008, 35 (10) :4649-4659
[6]   IMRT delivery to a moving target by dynamic MLC tracking: delivery for targets moving in two dimensions in the beam's eye view [J].
McQuaid, D. ;
Webb, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (19) :4819-4839
[7]  
RIT S, 2008, ON THE FLY MOTION 1, P729
[8]  
SONKE JJ, 2008, INT J RAD ONCOL BIOL
[9]   Errors and margins in radiotherapy [J].
van Herk, M .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :52-64
[10]  
VANHERK M, 2007, ON LINE 4D CONE BEAM, P6241