Measurement of end-expiratory lung volume in intubated children without interruption of mechanical ventilation

被引:12
|
作者
Bikker, Ido G. [1 ]
Scohy, Thierry V. [2 ]
Bogers, Ad J. J. C. [3 ]
Bakker, Jan [1 ]
Gommers, Diederik [1 ,2 ]
机构
[1] Erasmus MC, Dept Intens Care Med, NL-3015 CE Rotterdam, Netherlands
[2] Erasmus MC, Dept Anesthesiol, NL-3015 CE Rotterdam, Netherlands
[3] Erasmus MC, Dept Cardiothorac Surg, NL-3015 CE Rotterdam, Netherlands
关键词
Functional residual capacity; Pediatric; Positive-pressure respiration; Lung volume measurements; Anesthesiology; FUNCTIONAL RESIDUAL CAPACITY; COMPUTED-TOMOGRAPHY; HELIUM DILUTION; NITROGEN WASHOUT/WASHIN; REFERENCE VALUES; PRESSURE; INFANTS;
D O I
10.1007/s00134-009-1579-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Monitoring end-expiratory lung volume (EELV) is a valuable tool to optimize respiratory settings that could be of particular importance in mechanically ventilated pediatric patients. We evaluated the feasibility and precision of an intensive care unit (ICU) ventilator with an in-built nitrogen washout/washin technique in mechanically ventilated pediatric patients. Duplicate EELV measurements were performed in 30 patients between 5 kg and 43 kg after cardiac surgery (age, median + range: 26, 3-141 months). All measurements were taken during pressure-controlled ventilation at 0 cm H2O of positive end-expiratory pressure (PEEP). Linear regression between duplicate measurements was excellent (R (2) = 0.99). Also, there was good agreement between duplicate measurements, bias +/- A SD: -0.3% (-1.5 mL) +/- A 5.9% (19.2 mL). Mean EELV +/- A SD was 19.6 +/- A 5.1 mL/kg at 0 cm H2O PEEP. EELV correlated with age (p < 0.001, r = 0.92, R (2) = 0.78), body weight (p < 0.001, r = 0.91, R (2) = 0.82) and height (p < 0.001, r = 0.94, R (2) = 0.75). This ICU ventilator with an in-built nitrogen washout/washin EELV technique can measure EELV with precision, and can easily be used for mechanically ventilated pediatric patients.
引用
收藏
页码:1749 / 1753
页数:5
相关论文
共 50 条
  • [41] Influence of tidal volume and positive end-expiratory pressure on ventilation distribution and oxygenation during one-lung ventilation
    Zhao, Zhanqi
    Wang, Wei
    Zhang, Zuojing
    Xu, Meiying
    Frerichs, Inez
    Wu, Jingxiang
    Moeller, Knut
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (03)
  • [42] The influence of end-expiratory lung volume on measurements of pharyngeal collapsibility
    Owens, Robert L.
    Malhotra, Atul
    Eckert, Danny J.
    White, David P.
    Jordan, Amy S.
    JOURNAL OF APPLIED PHYSIOLOGY, 2010, 108 (02) : 445 - 451
  • [43] Control of end-expiratory lung volume:: component of the control of breathing
    Vízek, M
    JOURNAL OF PHYSIOLOGY-LONDON, 1998, 511P : 42S - 43S
  • [44] Estimation of end-expiratory lung volume variations by optoelectronic plethysmography
    Dellacà, RL
    Aliverti, A
    Pelosi, P
    Carlesso, E
    Chiumello, D
    Pedotti, A
    Gattinoni, L
    CRITICAL CARE MEDICINE, 2001, 29 (09) : 1807 - 1811
  • [45] Fractal Characteristics of End-Expiratory Lung Volume in Anesthetized Rats
    Xiaobin Zhang
    Eugene N. Bruce
    Annals of Biomedical Engineering, 2000, 28 : 94 - 101
  • [46] Positive end-expiratory pressure individualization guided by continuous end-expiratory lung volume monitoring during laparoscopic surgery
    Gerardo Tusman
    Mats Wallin
    Cecilia Acosta
    Bruno Santanera
    Facundo Portela
    Federico Viotti
    Nora Fuentes
    Magnus Hallbäck
    Fernando Suarez-Sipmann
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1557 - 1567
  • [47] End-expiratory lung volume and ventilation distribution with different continuous positive airway pressure systems in volunteers
    Andersson, B.
    Lundin, S.
    Lindgren, S.
    Stenqvist, O.
    Herges, H. Odenstedt
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (02) : 157 - 164
  • [48] The Proper Assessment of Pendelluft and Absolute End-Expiratory Lung Volume
    Wang, Yuxian
    Li, Jie
    Zhong, Ming
    Zhao, Zhanqi
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 208 (09) : 1001 - 1002
  • [49] Fractal characteristics of end-expiratory lung volume in anesthetized rats
    Zhang, XB
    Bruce, EN
    ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (01) : 94 - 101
  • [50] Total liquid ventilation with perfluorocarbons increases pulmonary end-expiratory volume and compliance in the setting of lung atelectasis
    Tooley, R
    Hirschl, RB
    Parent, A
    Bartlett, RH
    CRITICAL CARE MEDICINE, 1996, 24 (02) : 268 - 273