Self-humidifying effect of air self-circulation system for proton exchange membrane fuel cell engines

被引:25
作者
Zhang, Qinguo [1 ,2 ,3 ,4 ]
Tong, Zheming [1 ,2 ,3 ]
Tong, Shuiguang [1 ,2 ,3 ]
Cheng, Zhewu [1 ,2 ,3 ,4 ]
机构
[1] Zhejiang Univ, Ningbo Res Inst, Ningbo 315100, Peoples R China
[2] Zhejiang Univ, State Key Lab Fluid Power & Mechatron Syst, Hangzhou 310027, Peoples R China
[3] Zhejiang Univ, Sch Mech Engn, Hangzhou 310013, Peoples R China
[4] Zhejiang Univ, Ningbo Inst Technol, Ningbo 315100, Peoples R China
基金
中国国家自然科学基金;
关键词
Proton exchange membrane fuel cell (PEMFC); Cathode exhaust circulation; Self-humidifying effect; Liquid water saturation;
D O I
10.1016/j.renene.2020.10.105
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A dynamic mechanism model of a control-oriented hydrogen fuel cell system based on the cathode exhaust gas cycle is established, and the effects of operating parameters on the two-phase water transfer and dynamic output performance of a fuel cell are analyzed, the transport process of material and the spatial distribution of water content in the membrane electrode were obtained. The study found that too low humidity at the cathode inlet of the stack will cause corrosion of the catalyst layer and the carbon black carrier, resulting in agglomeration and sintering of the catalyst particles. The membrane is also severely damaged by mechanical properties, and black impurities and broken fibers are found on the membrane surface. Under the passive operation of the cathode self-circulation system, the maximum humidity of the mixed gas can reach 60%. The new system is advantageous to the evaporation of water vapor at higher operating temperature and can inhibit the flooding of membrane electrode assembly. It takes about 20s for the current to reach the steady state of the set value, and about 30s for the voltage to reach the steady state. The voltage fluctuation is small and the output power is stable, indicating high reliability. (c) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1143 / 1155
页数:13
相关论文
共 39 条
[1]   Experimental validation of two-phase pressure drop multiplier as a diagnostic tool for characterizing PEM fuel cell performance [J].
Banerjee, Rupak ;
Howe, Danielle ;
Mejia, Valentina ;
Kandlikar, Satish G. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (31) :17791-17801
[2]   Experimental investigation of two-phase flow pressure drop transients in polymer electrolyte membrane fuel cell reactant channels and their impact on the cell performance [J].
Banerjee, Rupak ;
Kandlikar, Satish G. .
JOURNAL OF POWER SOURCES, 2014, 268 :194-203
[3]   Enhancing under-rib mass transport in proton exchange membrane fuel cells using new serpentine flow field designs [J].
Baz, F. B. ;
Ookawara, Shinichi ;
Ahmed, Mahmoud .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (58) :30644-30662
[4]   Operating proton exchange membrane fuel cells without external humidification of the reactant gases - Fundamental aspects [J].
Buchi, FN ;
Srinivasan, S .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (08) :2767-2772
[5]   Numerical investigation of the coupled water and thermal management in PEM fuel cell [J].
Cao, Tao-Feng ;
Lin, Hong ;
Chen, Li ;
He, Ya-Ling ;
Tao, Wen-Quan .
APPLIED ENERGY, 2013, 112 :1115-1125
[6]   Performance degradation of a proton exchange membrane fuel cell with dead-ended cathode and anode [J].
Chen, Ben ;
Cai, Yonghua ;
Shen, Jun ;
Tu, Zhengkai ;
Chan, Siew Hwa .
APPLIED THERMAL ENGINEERING, 2018, 132 :80-86
[7]   Transient behavior of water transport in the membrane of a PEM fuel cell [J].
Chen, FL ;
Su, YG ;
Soong, CY ;
Yan, WM ;
Chu, HS .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 566 (01) :85-93
[8]   Influencing sensitivities of critical operating parameters on PEMFC output performance and gas distribution quality under different electrical load conditions [J].
Chen, Huicui ;
Liu, Biao ;
Zhang, Tong ;
Pei, Pucheng .
APPLIED ENERGY, 2019, 255
[9]   Numerical investigation of liquid water distribution in the cathode side of proton exchange membrane fuel cell and its effects on cell performance [J].
Chen, Li ;
Cao, Tao-Feng ;
Li, Zhao-Hui ;
He, Ya-Ling ;
Tao, Wen-Quan .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (11) :9155-9170
[10]   Transfer learning with deep neural networks for model predictive control of HVAC and natural ventilation in smart buildings [J].
Chen, Yujiao ;
Tong, Zheming ;
Zheng, Yang ;
Samuelson, Holly ;
Norford, Leslie .
JOURNAL OF CLEANER PRODUCTION, 2020, 254