Improvements in Cerebral Blood Flow and Recanalization Rates With Transcranial Diagnostic Ultrasound and Intravenous Microbubbles After Acute Cerebral Emboli

被引:23
作者
Gao, Shunji [1 ]
Zhang, Yan [2 ]
Wu, Juefei [1 ]
Shi, William T. [3 ]
Lof, John [1 ]
Vignon, Francois [3 ]
Drvol, Lucas [1 ]
Xie, Feng [1 ]
Muirhead, David [4 ]
Powers, Jeffry E. [5 ]
High, Robin [6 ]
White, Matthew L. [2 ]
Porter, Thomas R. [1 ]
机构
[1] Univ Nebraska Med Ctr, Div Cardiol, Dept Internal Med, Omaha, NE 68198 USA
[2] Univ Nebraska Med Ctr, Dept Radiol, Omaha, NE 68198 USA
[3] Philips Res North Amer, Briarcliff Manor, NY USA
[4] Univ Nebraska Med Ctr, Dept Pathol & Microbiol, Omaha, NE 68198 USA
[5] Philips Med Syst, Bothell, WA USA
[6] Univ Nebraska Med Ctr, Dept Biostat, Omaha, NE 68198 USA
关键词
stroke; therapeutic ultrasound; imaging; microbubbles; TISSUE-PLASMINOGEN ACTIVATOR; IN-VITRO; ACCELERATED THROMBOLYSIS; CAVITATION THRESHOLD; CLOT LYSIS; SONOTHROMBOLYSIS; STROKE; ENHANCEMENT; SAFETY; VIVO;
D O I
10.1097/RLI.0000000000000059
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Intravenous microbubbles (MBs) and transcutaneous ultrasound have been used to recanalize intra-arterial thrombi without the use of tissue plasminogen activator. In the setting of acute ischemic stroke, it was our objective to determine whether skull attenuation would limit the ability of ultrasound alone to induce the type and level of cavitation required to dissolve thrombi and improve cerebral blood flow (CBF) in acute ischemic stroke. Materials and Methods: In 40 pigs, bilateral internal carotid artery occlusions were created with 4-hour-old thrombi. Pigs were then randomized to high-mechanical index (MI = 2.4) short-pulse (5 microseconds) transcranial ultrasound (TUS) alone or a systemic MB infusion (3% Definity) with customized cavitation detection and imaging system transmitting either high-MI (2.4) short pulses (5 microseconds) or intermediate-MI (1.7) long pulses (20 microseconds). Angiographic recanalization rates of both internal carotids were compared in 24 of the pigs (8 per group), and quantitative analysis of CBF with perfusion magnetic resonance imaging was measured before, immediately after, and at 24 hours using T2* intensity versus time curves in 16 pigs. Results: Complete angiographic recanalization was achieved in 100% (8/8) of pigs treated with image-guided high-MI TUS and MBs, but in only 4 of 8 treated with high-MI TUS alone or 3 of 8 pigs treated with image-guided intermediate-MI TUS and MBs (both P < 0.05). Ipsilateral and contralateral CBF improved at 24 hours only after 2.4-MI 5-microsecond pulse treatments in the presence of MB (P < 0.005). There was no evidence of microvascular or macrovascular hemorrhage with any treatment. Conclusions: Guided high-MI impulses from an ultrasound imaging system produce sustained improvements in ipsilateral and contralateral CBF after acute cerebral emboli.
引用
收藏
页码:593 / 600
页数:8
相关论文
共 28 条
[1]   A pilot randomized clinical safety study of sonothrombolysis augmentation with ultrasound-activated perflutren-lipid microspheres for acute ischemic stroke [J].
Alexandrov, Andrei V. ;
Mikulik, Robert ;
Ribo, Marc ;
Sharma, Vijay K. ;
Lao, Annabelle Y. ;
Tsivgoulis, Georgios ;
Sugg, Rebecca M. ;
Barreto, Andrew ;
Sierzenski, Paul ;
Malkoff, Marc D. ;
Grotta, James C. .
STROKE, 2008, 39 (05) :1464-1469
[2]   Ultrasound-enhanced systemic thrombolysis for acute ischemic stroke [J].
Alexandrov, AV ;
Molina, CA ;
Grotta, JC ;
Garami, Z ;
Ford, SR ;
Alvarez-Sabin, J ;
Montaner, J ;
Saqqur, M ;
Demchuk, AM ;
Moye, LA ;
Hill, MD ;
Wojner, AW ;
Al-Senani, F ;
Burgin, S ;
Calleja, S ;
Campbell, M ;
Chen, CI ;
Chernyshev, O ;
Choi, J ;
El-Mitwalli, A ;
Felberg, R ;
Ford, S ;
Garami, Z ;
Irr, W ;
Grotta, J ;
Hall, C ;
Iguchi, Y ;
Ireland, J ;
Labiche, L ;
Malkoff, M ;
Morgenstern, L ;
Noser, E ;
Okon, N ;
Piriyawat, P ;
Robinson, D ;
Shaltoni, H ;
Shaw, S ;
Uchino, K ;
Yatsu, F ;
Alvarez-Sabín, J ;
Arenillas, JF ;
Huertas, R ;
Molina, C ;
Montaner, J ;
Ribó, M ;
Rubiera, M ;
Santamarina, E ;
Saqqur, M ;
Alchtar, N ;
O'Rourke, F .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (21) :2170-2178
[3]   Destruction of contrast microbubbles by ultrasound - Effects on myocardial function, coronary perfusion pressure, and microvascular integrity [J].
Ay, T ;
Havaux, X ;
Van Camp, G ;
Campanelli, B ;
Gisellu, G ;
Pasquet, A ;
Denef, JF ;
Melin, JA ;
Vanoverschelde, JLJ .
CIRCULATION, 2001, 104 (04) :461-466
[4]   Microbubbles Improve Sonothrombolysis In Vitro and Decrease Hemorrhage In Vivo in a Rabbit Stroke Model [J].
Brown, Aliza T. ;
Flores, Rene ;
Hamilton, Eric ;
Roberson, Paula K. ;
Borrelli, Michael J. ;
Culp, William C. .
INVESTIGATIVE RADIOLOGY, 2011, 46 (03) :202-207
[5]   Intracranial clot lysis with intravenous microbubbles and transcranial ultrasound in swine [J].
Culp, WC ;
Porter, TR ;
Lowery, J ;
Xie, F ;
Roberson, PK ;
Marky, L .
STROKE, 2004, 35 (10) :2407-2411
[6]   Successful Microbubble Sonothrombolysis Without Tissue-Type Plasminogen Activator in a Rabbit Model of Acute Ischemic Stroke [J].
Culp, William C. ;
Flores, Rene ;
Brown, Aliza T. ;
Lowery, John D. ;
Roberson, Paula K. ;
Hennings, Leah J. ;
Woods, Sean D. ;
Hatton, Jeff H. ;
Culp, Benjamin C. ;
Skinner, Robert D. ;
Borrelli, Michael J. .
STROKE, 2011, 42 (08) :2280-2285
[7]   Correlation of cavitation with ultrasound enhancement of thrombolysis [J].
Datta, Saurabh ;
Coussios, Constantin-C. ;
McAdory, Louis E. ;
Tan, Jun ;
Porter, Tyrone ;
De Courten-Myers, Gabrielle ;
Holland, Christy K. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (08) :1257-1267
[8]   Effect of ultrasound on thrombolysis of middle cerebral artery occlusion [J].
Eggers, J ;
Koch, B ;
Meyer, K ;
König, I ;
Seidel, G .
ANNALS OF NEUROLOGY, 2003, 53 (06) :797-800
[9]   Cavitational mechanisms in ultrasound-accelerated thrombolysis at 1 MHz [J].
Everbach, EC ;
Francis, CW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (07) :1153-1160
[10]   Microbubble-Augmented Ultrasound Sonothrombolysis Decreases Intracranial Hemorrhage in a Rabbit Model of Acute Ischemic Stroke [J].
Flores, Rene ;
Hennings, Leah J. ;
Lowery, John D. ;
Brown, Aliza T. ;
Culp, William C. .
INVESTIGATIVE RADIOLOGY, 2011, 46 (07) :419-424