Dynamic fatigue resistance of implant-abutment junction in an internally notched morse-taper oral implant:: influence of abutment design

被引:55
作者
Çehreli, MC [1 ]
Akça, K [1 ]
Iplikçioglu, H [1 ]
Sahin, S [1 ]
机构
[1] Hacettepe Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
关键词
abutment design; fatigue failure; mechanical complications; morse-taper; one-piece abutment; two-piece abutment;
D O I
10.1111/j.1600-0501.2004.01023.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare dynamic fatigue resistance of one- and two-piece abutments connected to internally notched morse-taper oral implants. Material and methods: Sixteen synOcta(R) ITI(R) implants were tightened into two metal models. SynOcta(R) abutments for cement-retained restorations and solid abutments were divided into two equal groups and were torque-tightened into the implants. Each implant received a cement-retained crown. Cyclic dynamic axial and lateral peak loads of 75+/-5 N were applied on the implants for a duty of 500,000 cycles at 0.5 Hz, and at an angle of 20degrees. Prior to the experiments and at each 100,000 cycles of loading, periotest values (PTVs) were measured. Removal torque values (RTVs) of the abutments were also measured with a custom-made torque device at the termination of the experiment. Results: All abutments and implants were clinically immobile and without any signs of mechanical failure. The final PTVs for both abutments were similar and the difference between groups was insignificant (P>0.05). The RTVs of solid abutments were significantly higher than synOcta(R) abutments (P<0.05). Conclusion: Predictable long-term clinical results can be achieved with solid abutments and synOcta(R) abutments for cement-retained restorations. Solid abutments possess higher removal torque resistance than synOcta(R) abutments when connected to synOcta(R) ITI(R) implants.
引用
收藏
页码:459 / 465
页数:7
相关论文
共 31 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]   Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant -: A nonlinear finite element stress analysis [J].
Akça, K ;
Çehreli, MC ;
Iplikçioglu, H .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (04) :444-454
[3]  
Akça K, 2002, INT J ORAL MAX IMPL, V17, P536
[4]  
Avivi-Arber L, 1996, Int J Oral Maxillofac Implants, V11, P311
[5]  
Behneke A, 2000, INT J ORAL MAX IMPL, V15, P633
[6]  
Binon PP, 2000, INT J ORAL MAX IMPL, V15, P76
[7]   Long-term evaluation of non-submerged ITI implants .1. 8-year life table analysis of a prospective multi-center study with 2359 implants [J].
Buser, D ;
MericskeStern, R ;
Bernard, JP ;
Behneke, A ;
Behneke, N ;
Hirt, HP ;
Belser, UC ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (03) :161-172
[8]  
Chee W, 1999, INT J ORAL MAX IMPL, V14, P137
[9]   Biological factors contributing to failures of osseointegrated oral implants - (II). Etiopathogenesis [J].
Esposito, M ;
Hirsch, JM ;
Lekholm, U ;
Thomsen, P .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1998, 106 (03) :721-764
[10]  
Esposito M, 1999, INT J ORAL MAX IMPL, V14, P473