Digital vs. analog PET/CT: intra-subject comparison of the SUVmax in target lesions and reference regions

被引:48
作者
Fuentes-Ocampo, Francisco [1 ]
Alfonso Lopez-Mora, Diego [1 ]
Flotats, Albert [1 ]
Paillahueque, Gabriela [2 ]
Camacho, Valle [1 ]
Duch, Joan [1 ]
Fernandez, Alejandro [1 ]
Domenech, Anna [1 ]
Estorch, Montserrat [1 ]
Carrio, Ignasi [1 ]
机构
[1] Autonomous Univ Barcelona, Hosp St Pau, Nucl Med Dept, St Antoni M Claret 167, Barcelona 08025, Spain
[2] Univ Chile, Hosp Clin, Nucl Med Dept, Santiago, Chile
关键词
Digital PET; CT; Analog PET; SUVmax; Intra-subject comparison; PROSTATE-CANCER; TIME-POINT; EXPERIENCE;
D O I
10.1007/s00259-018-4256-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe purpose of this study was to assess whether digital photon counting technology in digital PET/CT influences the quantification of SUVmax in target lesions and regions of reference compared to analog PET/CT before an interchangeable use of either system in follow up studies.MethodsFrom January to June of 2018, 100 oncological patients underwent successive PET/CT imaging with digital and analog systems in the same day. Fifty-eight patients underwent analog imaging first and digital imaging thereafter, and 42 patients the other way round. SUVmax was measured in reference regions (liver and mediastinal blood pool) and in the most metabolically active target lesion in each patient. According to the sequence order of PET/CT acquisition, two groups of SUVmax values were obtained, i.e. group 1: analog PET/CT performed first; group 2: digital PET/CT performed first.ResultsMean SUVmax in the total sample (regardless of the order of PET/CT acquisition) in the target lesions with the analog PET/CT was 8.146.39 and the digital 9.976.14 (P=0.000). Total mean SUVmax in the liver with the analog was 4.392.59 and the digital 4.463.18 (P=0.477). Total mean SUVmax in the mediastinal blood pool with the analog was 2.30 +/- 0.67 and the digital 2.54 +/- 0.74 (P=0.000).Group 1: mean SUVmax in the target lesions with the analog system was 6.64 +/- 4.71 and the digital 9.48 +/- 5.60 (P=0.000). Mean liver SUVmax with the analog was 4.70 +/- 2.90 and the digital 4.80 +/- 3.72 (P=0.088). Mediastinal blood pool SUVmax with the analog was 2.33 +/- 0.66 and the digital 2.45 +/- 0.73 (P=0.041).Group 2: mean SUVmax in target lesions with the digital system was 10.63 +/- 6.88 and the analog 10.16 +/- 7.76 (P=0.046). Mean liver SUVmax with the digital was 3.99 +/- 2.20 and the analog 3.96 +/- 2.04 (P=0.218). Mediastinal blood pool SUVmax with the digital was 2.66 +/- 0.75 and the analog 2.27 +/- 0.68 (P=0.000).No significant differences between both time delays were found.ConclusionsImproved photon counting technology in the digital PET/CT, and the effect of delayed increased uptake and retention significantly increases SUVmax values. This has to be taken into account before interchangeable use of either system in follow up studies.
引用
收藏
页码:1745 / 1750
页数:6
相关论文
共 19 条
  • [1] Impact of point spread function modelling and time of flight on FDG uptake measurements in lung lesions using alternative filtering strategies
    Armstrong I.S.
    Kelly M.D.
    Williams H.A.
    Matthews J.C.
    [J]. EJNMMI Physics, 1 (1) : 1 - 18
  • [2] 18F Choline PET/CT in the Preoperative Staging of Prostate Cancer in Patients with Intermediate or High Risk of Extracapsular Disease: A Prospective Study of 130 Patients
    Beheshti, Mohsen
    Imamovic, Larisa
    Broinger, Gabriele
    Vali, Reza
    Waldenberger, Peter
    Stoiber, Franz
    Nader, Michael
    Gruy, Bernhard
    Janetschek, Guenter
    Langsteger, Werner
    [J]. RADIOLOGY, 2010, 254 (03) : 925 - 933
  • [3] Boellaard R, 2004, J NUCL MED, V45, P1519
  • [4] Dynamic Changes of FDG Uptake and Clearance in Normal Tissues
    Cheng, Gang
    Alavi, Abass
    Lim, Esther
    Werner, Thomas J.
    Del Bello, Catherine V.
    Akers, Scott R.
    [J]. MOLECULAR IMAGING AND BIOLOGY, 2013, 15 (03) : 345 - 352
  • [5] When should we recommend use of dual time-point and delayed time-point imaging techniques in FDG PET?
    Cheng, Gang
    Torigian, Drew A.
    Zhuang, Hongming
    Alavi, Abass
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (05) : 779 - 787
  • [6] Increasing Uptake Time in FDG-PET: Standardized Uptake Values in Normal Tissues at 1 versus 3 h
    Chin, Bennett B.
    Green, Edward D.
    Turkington, Timothy G.
    Hawk, Thomas C.
    Coleman, R. Edward
    [J]. MOLECULAR IMAGING AND BIOLOGY, 2009, 11 (02) : 118 - 122
  • [7] [18F]fluorocholine PET/CT imaging for the detection of recurrent prostate cancer at PSA relapse:: experience in 100 consecutive patients
    Cimitan, Marino
    Bortolus, Roberto
    Morassut, Sandro
    Canzonieri, Vincenzo
    Garbeglio, Antonio
    Baresic, Tanja
    Borsatti, Eugenio
    Drigo, Annalisa
    Trovo, Mauro G.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (12) : 1387 - 1398
  • [8] The Digital Silicon Photomultiplier - Principle of Operation and Intrinsic Detector Performance
    Frach, Thomas
    Prescher, Gordian
    Degenhardt, Carsten
    de Gruyter, Rik
    Schmitz, Anja
    Ballizany, Rob
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1959 - 1965
  • [9] Jaskowiak CJ, 2005, J NUCL MED, V46, P424
  • [10] Kwee SA, 2006, J NUCL MED, V47, P262