Online Decoding of Hidden Markov Models for Gait Event Detection Using Foot-Mounted Gyroscopes

被引:94
作者
Mannini, Andrea [1 ]
Genovese, Vincenzo [1 ]
Sabatini, Angelo Maria [1 ]
机构
[1] Scuola Super StAnna, BioRobot Inst, I-56127 Pisa, Italy
关键词
Gait event detection; gyroscope; hidden Markov model (HMM); human movement analysis; short-time Viterbi (STV); AMBULATORY SYSTEM; MOTION TRACKING; PHASE DETECTION; PARAMETERS; IMPLEMENTATION; ACCELEROMETER; STROKE;
D O I
10.1109/JBHI.2013.2293887
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, we present an approach to the online implementation of a gait event detector based on machine learning algorithms. Gait events were detected using a uniaxial gyro that measured the foot instep angular velocity in the sagittal plane to feed a four-state left-right hidden Markov model (HMM). The short-time Viterbi algorithm was used to overcome the limitation of the standard Viterbi algorithm, which does not allow the online decoding of hidden state sequences. Supervised learning of the HMM structure and validation with the leave-one-subject-out validation method were performed using treadmill gait reference data from an optical motion capture system. The four gait events were foot strike, flat foot (FF), heel off (HO), and toe off. The accuracy ranged, on average, from 45 ms (early detection, FF) to 35 ms (late detection, HO); the latency of detection was less than 100 ms for all gait events but the HO, where the probability that it was greater than 100 ms was 25%. Overground walking tests of the HMM-based gait event detector were also successfully performed.
引用
收藏
页码:1122 / 1130
页数:9
相关论文
共 34 条
[1]   A kinematic comparison of overground and treadmill walking [J].
Alton, F ;
Baldey, L ;
Caplan, S ;
Morrissey, MC .
CLINICAL BIOMECHANICS, 1998, 13 (06) :434-440
[2]   Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement [J].
Aminian, K ;
Trevisan, C ;
Najafi, B ;
Dejnabadi, H ;
Frigo, C ;
Pavan, E ;
Telonio, A ;
Cerati, F ;
Marinoni, EC ;
Robert, P ;
Leyvraz, PF .
GAIT & POSTURE, 2004, 20 (01) :102-107
[3]   Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes [J].
Aminian, K ;
Najafi, B ;
Büla, C ;
Leyvraz, PF ;
Robert, P .
JOURNAL OF BIOMECHANICS, 2002, 35 (05) :689-699
[4]  
Ardo H., 2007, P IEEE WORKSH MOT VI, P1
[5]   Gait phase analysis based on a Hidden Markov Model [J].
Bae, Joonbum ;
Tomizuka, Masayoshi .
MECHATRONICS, 2011, 21 (06) :961-970
[6]   Gait analysis using a shoe-integrated wireless sensor system [J].
Bamberg, Stacy J. Morris ;
Benbasat, Ari Y. ;
Scarborough, Donna Moxley ;
Krebs, David E. ;
Paradiso, Joseph A. .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2008, 12 (04) :413-423
[7]   Inertial Sensor Technology Trends [J].
Barbour, Neil ;
Schmidt, George .
IEEE SENSORS JOURNAL, 2001, 1 (04) :332-339
[8]   Short-time Viterbi for online HMM decoding: Evaluation on a real-time phone recognition task [J].
Bloit, Julien ;
Rodet, Xavier .
2008 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-12, 2008, :2121-2124
[9]   Validity of the prosthetic activity monitor to assess the duration and spatio-temporal characteristics of prosthetic walking [J].
Bussmann, JBJ ;
Culhane, KM ;
Horemans, HLD ;
Lyons, GM ;
Stam, HJ .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2004, 12 (04) :379-386
[10]   Pedestrian tracking with shoe-mounted inertial sensors [J].
Foxlin, E .