Portable Automated Rapid Testing (PART) for auditory assessment: Validation in a young adult normal-hearing population

被引:30
作者
de Larrea-Mancera, E. Sebastian Lelo [1 ,2 ]
Stavropoulos, Trevor [2 ]
Hoover, Eric C. [3 ]
Eddins, David A. [4 ]
Gallun, Frederick J. [5 ]
Seitz, Aaron R. [1 ,2 ]
机构
[1] Univ Calif Riverside, Psychol Dept, 900 Univ Ave, Riverside, CA 92521 USA
[2] Univ Calif Riverside, Brain Game Ctr, 1201 Univ Ave, Riverside, CA 92521 USA
[3] Univ Maryland, College Pk, MD 20742 USA
[4] Univ S Florida, Tampa, FL 33620 USA
[5] Oregon Hlth & Sci Univ, Portland, OR 97239 USA
基金
美国国家卫生研究院;
关键词
MODULATION TRANSFER-FUNCTIONS; FIXED STEP SIZES; FREQUENCY-MODULATION; SPEECH RECOGNITION; FILTER BANDWIDTHS; CODING FREQUENCY; SPATIAL RELEASE; GAP DETECTION; OLDER-ADULTS; AGE;
D O I
10.1121/10.0002108
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study aims to determine the degree to which Portable Automated Rapid Testing (PART), a freely available program running on a tablet computer, is capable of reproducing standard laboratory results. Undergraduate students were assigned to one of three within-subject conditions that examined repeatability of performance on a battery of psychoacoustical tests of temporal fine structure processing, spectro-temporal amplitude modulation, and targets in competition. The repeatability condition examined test/retest with the same system, the headphones condition examined the effects of varying headphones (passive and active noise-attenuating), and the noise condition examined repeatability in the presence of recorded cafeteria noise. In general, performance on the test battery showed high repeatability, even across manipulated conditions, and was similar to that reported in the literature. These data serve as validation that suprathreshold psychoacoustical tests can be made accessible to run on consumer-grade hardware and perform in less controlled settings. This dataset also provides a distribution of thresholds that can be used as a normative baseline against which auditory dysfunction can be identified in future work.
引用
收藏
页码:1831 / 1851
页数:21
相关论文
共 89 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   The power of analogies [J].
不详 .
NATURE PHOTONICS, 2014, 8 (01) :1-1
[3]  
[Anonymous], 2013, INT J TRANSIT JUST, V7, P1, DOI DOI 10.3389/FNINS.2013.00252
[4]  
[Anonymous], 1988, J ACOUST SOC AM, V83, P859, DOI DOI 10.1121/1.395965
[5]  
[Anonymous], 1990, PUBLICATION I MATH, V47, P103, DOI DOI 10.1016/0378-5955(90)90170-T
[6]  
[Anonymous], 2015, RIV STORICA ITAL, V6, P1, DOI DOI 10.3389/fpls.2015.00951
[7]  
ANSI, 2004, R2019, S3.21
[8]   ERRORS ON THE STAGGERED SPONDAIC WORD (SSW) TEST IN A GROUP OF ADULT NORMAL LISTENERS [J].
ARNST, DJ .
EAR AND HEARING, 1981, 2 (03) :112-116
[9]  
BERGMAN M, 1992, British Journal of Audiology, V26, P15, DOI 10.3109/03005369209077867
[10]   Spectrotemporal Modulation Sensitivity as a Predictor of Speech Intelligibility for Hearing-Impaired Listeners [J].
Bernstein, Joshua G. W. ;
Mehraei, Golbarg ;
Shamma, Shihab ;
Gallun, Frederick J. ;
Theodoroff, Sarah M. ;
Leek, Marjorie R. .
JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2013, 24 (04) :293-306