Predictors of rate-adaptive pacing in patients implanted with implantable cardioverter-defibrillator and subsequent differential clinical outcomes

被引:2
作者
Kallner, Nils [1 ]
Nishimura, Marin [2 ]
Birgersdotter-Green, Ulrika [2 ]
Hoffmayer, Kurt S. [2 ]
Han, Frederick T. [2 ]
Krummen, David E. [2 ]
Raissi, Farshad [2 ]
Feld, Gregory K. [2 ]
Hsu, Jonathan C. [2 ]
机构
[1] Linkoping Univ Hosp, Linkoping, Sweden
[2] Univ Calif San Diego, Dept Med, Div Cardiol, Cardiac Electrophysiol Sect, 9452 Med Ctr Dr,3rd Fl,Rm 3E-417, La Jolla, CA 92037 USA
关键词
Cardiac resynchronization therapy; Cardiomyopathy; Chronotropic incompetence; Implantable cardioverter-defibrillator; Rate-adaptive pacing; Sick sinus syndrome; CARDIAC-RESYNCHRONIZATION THERAPY; CHRONOTROPIC INCOMPETENCE; HEART-FAILURE; EXERCISE;
D O I
10.1007/s10840-019-00536-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposePatients with severe cardiomyopathy often have chronotropic incompetence, which is predominantly managed by activating rate-adaptive pacing in patients implanted with an implantable cardioverter-defibrillator (ICD) capable of atrial pacing. The purpose of this study was to determine predictors of rate-adaptive pacing activation, the cumulative incidence of activation, and the association of rate-adaptive pacing activation with subsequent clinical outcomes in an ICD population.MethodsThe authors evaluated 228 patients implanted with an ICD between 2011 and 2015. Multivariable logistic regression was used to evaluate predictors of rate-adaptive pacing activation. Cox proportional-hazards regression was used to examine associations of rate-adaptive pacing activation and clinical outcomes.ResultsRate-adaptive pacing was turned on in 38.5% (n=88) of patients during follow-up. Several statistically significant predictors of rate-adaptive pacing activation were found, particularly previous atrial fibrillation (odds ratio [OR]=8.27, 95% confidence interval [CI]=2.96-23.06, p<0.001), previous myocardial infarction (OR=4.17, 95% CI=1.38-12.58, p=0.01), and non-ischemic cardiomyopathy (OR=3.83, 95% CI=1.22-12.00, p=0.02). In multivariable adjusted analyses, rate-adaptive pacing activation within 30days of implantation was not associated with the risk of device therapy for tachyarrhythmias (hazard ratio [HR]=1.52, 95% CI=0.71-3.28, p=0.29), atrial fibrillation (HR=1.42, 95% CI=0.71-2.87, p=0.32), HF re-admission (HR=1.39, 95% CI=0.80-2.43, p=0.25), nor all-cause mortality (HR=2.34, 95% CI=0.80-6.84, p=0.12).ConclusionsDuring follow-up, more than one in three HF patients implanted with an ICD developed the need for rate-adaptive pacing. Atrial fibrillation, prior myocardial infarction, and non-ischemic cardiomyopathy were statistically significant baseline clinical predictors of rate-adaptive pacing activation. Rate-adaptive pacing activation was not associated with subsequent adverse clinical outcomes.
引用
收藏
页码:83 / 91
页数:9
相关论文
共 22 条
[1]  
Alt E, 1999, AM J CARDIOL, V83, p17D
[2]  
Bardy GH, 2005, NEW ENGL J MED, V352, P2146
[3]  
Bonow RO, 2008, J AM COLL CARDIOL, V52, pE1, DOI [10.1016/j.jacc.2008.05.007, 10.1016/j.hrthm.2008.04.014, 10.1016/j.jacc.2008.02.032]
[4]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[5]   Chronotropic Incompetence Causes, Consequences, and Management [J].
Brubaker, Peter H. ;
Kitzman, Dalane W. .
CIRCULATION, 2011, 123 (09) :1010-1020
[6]  
Calkins H, 2017, HEART RHYTHM, V14, pE275, DOI [10.1093/europace/eux274, 10.1016/j.hrthm.2017.05.012, 10.1093/europace/eux275]
[7]   The efficacy and safety of cardiac resynchronization therapy combined with implantable cardioverter defibrillator for heart failure: a meta-analysis of 5674 patients [J].
Chen, Shaojie ;
Ling, Zhiyu ;
Kiuchi, Marcio Galindo ;
Yin, Yuehui ;
Krucoff, Mitchell W. .
EUROPACE, 2013, 15 (07) :992-1001
[8]   CHRONOTROPIC INCOMPETENCE IN CHRONIC HEART-FAILURE [J].
CLARK, AL ;
COATS, AJS .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1995, 49 (03) :225-231
[9]   Atrial Rate-Responsive Pacing and Incidence of Sustained Atrial Arrhythmias in Patients with Implantable Cardioverter Defibrillators [J].
Fontenla, Adolfo ;
Salguero, Rafael ;
Martinez-Ferrer, Jose B. ;
Rodriguez, Anibal ;
Alzueta, Javier ;
Garcia, Enrique ;
Basterra, Nuria ;
Romero, Rafael ;
Fernandez De la Concha, Joaquin ;
Vinolas, Xavier ;
Villacastin, Julian ;
Lopez-Gil, Maria ;
Arribas, Fernando .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2016, 39 (06) :548-556
[10]   Resting heart rate in cardiovascular disease [J].
Fox, Kim ;
Borer, Jeffrey S. ;
Camm, A. John ;
Danchin, Nicolas ;
Ferrari, Roberto ;
Lopez Sendon, Jose L. ;
Steg, Philippe Gabriel ;
Tardif, Jean-Claude ;
Tavazzi, Luigi ;
Tendera, Michal .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (09) :823-830