Accelerated Isotropic Sub-Millimeter Whole-Heart Coronary MRI: Compressed Sensing Versus Parallel Imaging

被引:62
作者
Akcakaya, Mehmet [1 ,2 ]
Basha, Tamer A. [1 ,2 ]
Chan, Raymond H. [1 ,2 ]
Manning, Warren J. [1 ,2 ,3 ]
Nezafat, Reza [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
关键词
compressed sensing; accelerated imaging; parallel imaging; whole-heart coronary MRI; sub-millimeter; high resolution imaging; MAGNETIC-RESONANCE ANGIOGRAPHY; INTRAVASCULAR CONTRAST AGENT; T SPARSE-SENSE; BREATH-HOLD; SPATIAL-RESOLUTION; RESPIRATORY MOTION; SLOW INFUSION; SINGLE-CENTER; TESLA; ARTERIES;
D O I
10.1002/mrm.24683
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo enable accelerated isotropic sub-millimeter whole-heart coronary MRI within a 6-min acquisition and to compare this with a current state-of-the-art accelerated imaging technique at acceleration rates beyond what is used clinically. MethodsCoronary MRI still faces major challenges, including lengthy acquisition time, low signal-to-noise-ratio (SNR), and suboptimal spatial resolution. Higher spatial resolution in the sub-millimeter range is desirable, but this results in increased acquisition time and lower SNR, hindering its clinical implementation. In this study, we sought to use an advanced B-1-weighted compressed sensing technique for highly accelerated sub-millimeter whole-heart coronary MRI, and to compare the results to parallel imaging, the current-state-of-the-art, where both techniques were used at acceleration rates beyond what is used clinically. Two whole-heart coronary MRI datasets were acquired in seven healthy adult subjects (30.312.1 years; 3 men), using prospective 6-fold acceleration, with random undersampling for the proposed compressed sensing technique and with uniform undersampling for sensitivity encoding reconstruction. Reconstructed images were qualitatively compared in terms of image scores and perceived SNR on a four-point scale (1=poor, 4=excellent) by an experienced blinded reader. ResultsThe proposed technique resulted in images with clear visualization of all coronary branches. Overall image quality and perceived SNR of the compressed sensing images were significantly higher than those of parallel imaging (P=0.03 for both), which suffered from noise amplification artifacts due to the reduced SNR. ConclusionThe proposed compressed sensing-based reconstruction and acquisition technique for sub-millimeter whole-heart coronary MRI provides 6-fold acceleration, where it outperforms parallel imaging with uniform undersampling. Magn Reson Med 71:815-822, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:815 / 822
页数:8
相关论文
共 45 条
[1]   Accelerated Late Gadolinium Enhancement Cardiac MR Imaging with Isotropic Spatial Resolution Using Compressed Sensing: Initial Experience1 [J].
Akcakaya, Mehmet ;
Rayatzadeh, Hussein ;
Basha, Tamer A. ;
Hong, Susie N. ;
Chan, Raymond H. ;
Kissinger, Kraig V. ;
Hauser, Thomas H. ;
Josephson, Mark E. ;
Manning, Warren J. ;
Nezafat, Reza .
RADIOLOGY, 2012, 264 (03) :691-699
[2]   Accelerated contrast-enhanced whole-heart coronary MRI using low-dimensional-structure self-learning and thresholding [J].
Akcakaya, Mehmet ;
Basha, Tamer A. ;
Chan, Raymond H. ;
Rayatzadeh, Hussein ;
Kissinger, Kraig V. ;
Goddu, Beth ;
Goepfert, Lois A. ;
Manning, Warren J. ;
Nezafat, Reza .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) :1434-1443
[3]   Low-dimensional-Structure Self-Learning and Thresholding: Regularization Beyond Compressed Sensing for MRI Reconstruction [J].
Akcakaya, Mehmet ;
Basha, Tamer A. ;
Goddu, Beth ;
Goepfert, Lois A. ;
Kissinger, Kraig V. ;
Tarokh, Vahid ;
Manning, Warren J. ;
Nezafat, Reza .
MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (03) :756-767
[4]   Compressed Sensing With Wavelet Domain Dependencies for Coronary MRI: A Retrospective Study [J].
Akcakaya, Mehmet ;
Nam, Seunghoon ;
Hu, Peng ;
Moghari, Mehdi H. ;
Ngo, Long H. ;
Tarokh, Vahid ;
Manning, Warren J. ;
Nezafat, Reza .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (05) :1090-1099
[5]   Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3 T With Radial EPI [J].
Bhat, Himanshu ;
Yang, Qi ;
Zuehlsdorff, Sven ;
Li, Kuncheng ;
Li, Debiao .
MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) :82-91
[6]   3D Radial Sampling and 3D Affine Transform-based Respiratory Motion Correction Technique for Free-breathing Whole-Heart Coronary MRA with 100% Imaging Efficiency [J].
Bhat, Himanshu ;
Ge, Lan ;
Nielles-Vallespin, Sonia ;
Zuehlsdorff, Sven ;
Li, Debiao .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) :1269-1277
[7]   Whole-heart coronary magnetic resonance angiography at 3 Tesla in 5 minutes with slow infusion of Gd-BOPTA, a high-relaxivity clinical contrast agent [J].
Bi, Xiaoming ;
Carr, James C. ;
Li, Debiao .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (01) :1-7
[8]   Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint [J].
Block, Kai Tobias ;
Uecker, Martin ;
Frahm, Jens .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) :1086-1098
[9]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[10]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696