Design and characterization of a photometer-colorimeter standard

被引:13
作者
Eppeldauer, GP [1 ]
Rácz, M
机构
[1] Natl Inst Stand & Technol, Opt Technol Div, Gaithersburg, MD 20899 USA
[2] Hungarian Acad Sci, Konkoly Observ, H-1525 Budapest, Hungary
[3] Hungarian Acad Sci, Res Inst Tech Phys & Mat Sci, H-1525 Budapest, Hungary
关键词
D O I
10.1364/AO.43.002621
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A photometer and tristimulus colorimeter has been developed at the National Institute of Standards and Technology (NIST) to realize a color scale. A novel construction was developed to implement the spectral-responsivity-based scale with small uncertainty. The new device can be used as a reference illuminance and luminance meter as well. Temperature-controlled filter combinations, with 5-8 layers in one package, are used to match the responsivity of a silicon tunnel-trap detector to the CIE color-matching functions with small spectral mismatch values (f(1)'). Design considerations to extend the tunnel-trap detector with replaceable single and double apertures and changeable filter combinations are described. The design and fabrication of the filter packages and the dependence of the f(1)' values on the thickness of the filter layers are discussed. The colorimeter was characterized for angular, spatial, and spectral responsivity. An improved preamplifier can convert current to voltage in an 11-decade dynamic range with 0.01% uncertainty. (C) 2004 Optical Society of America.
引用
收藏
页码:2621 / 2631
页数:11
相关论文
共 10 条
  • [1] Calibration and characterization of trap detector filter radiometers
    Allen, DW
    Eppeldauer, GP
    Brown, SW
    Early, EA
    Johnson, BC
    Lykke, KR
    [J]. EARTH OBSERVING SYSTEMS VIII, 2003, 5151 : 471 - 479
  • [2] *CENTR BUR CIE, 1986, PUBL CIE, V152
  • [3] *CENTR BUR CIE, 1987, PUBL CIE, V69
  • [4] CZIBULA G, 1982, P INT MEAS CONF IMEK, V1, P189
  • [5] DEPPELDAUER GP, 2003, P 25 SESS CIE CENTR, V1
  • [6] Spectral response based calibration method of Tristimulus colorimeters
    Eppeldauer, G
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1998, 103 (06) : 615 - 619
  • [7] Realization of a spectral radiance responsivity scale with a laser-based source and Si radiance meters
    Eppeldauer, GP
    Brown, SW
    Larason, TC
    Rácz, M
    Lykke, KR
    [J]. METROLOGIA, 2000, 37 (05) : 531 - 534
  • [8] Opto-mechanical and electronic design of a tunnel-trap Si radiometer
    Eppeldauer, GP
    Lynch, DC
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2000, 105 (06) : 813 - 828
  • [9] Realization of a scale of absolute spectral response using the national institute of standards and technology high-accuracy cryogenic radiometer
    Gentile, TR
    Houston, JM
    Cromer, CL
    [J]. APPLIED OPTICS, 1996, 35 (22): : 4392 - 4403
  • [10] MAKAI JP, 1984, P INT MEAS CONF IMEK, P215